NARDA PMM 1008 User manual

NARDA
Safety
Test
Solutions
S.r.l. Socio Unico
Sales & Support:
Via Rimini, 22
20142 - Milano (MI)
Tel.: +39 02 581881
Fax: +39 02 58188273
Manufacturing Plant:
Via Benessea, 29/B
17035 - Cisano sul Neva (SV)
Tel.: +39 0182 58641
Fax: +39 0182 586400
http://www.narda-sts.it
SERIAL NUMBER OF THE INSTRUMENT
You can find the Series Number on the rear panel of the instrument.
Series Number is in the form: 0000X00000.
The first four digits and the letter are the Series Number prefix, the last five digits
are the Series Number suffix. The prefix is the same for identical instruments, it
changes only when a configuration change is made to the instrument.
The suffix is different for each instrument.
Document 1008EN-00519-1.27 – Copyright © NARDA 2020
User’s Manual
PMM 1008
MAGNETIC FIELD GENERATOR

II Note and symbols
NOTE:
If the instrument is used in any other way than as described in this Users Manual, it may become unsafe
Before using this product, the related documentation must be read with great care and fully understood to
familiarize with all the safety prescriptions.
To ensure the correct use and the maximum safety level, the User shall know all the instructions and
recommendations contained in this document.
This product is a Safety Class Iand Installation Category II instrument according to IEC classification and
has been designed to meet the requirements of EN61010-1 (Safety Requirements for Electrical Equipment for
Measurement, Control and Laboratory Use).
This product has a Pollution Degree II normally only non-conductive pollution occurs. Occasionally, however,
a temporary conductivity caused by condensation must be expected.
The information contained in this document is subject to change without notice.
KEY TO THE ELECTRIC AND SAFETY SYMBOLS:
You now own a high-quality instrument that will give you many years of reliable service.
Nevertheless, even this product will eventually become obsolete. When that time comes,
please remember that electronic equipment must be disposed of in accordance with local
regulations. This product conforms to the WEEE Directive of the European Union
(2002/96/EC) and belongs to Category 9 (Monitoring and Control Instruments). You can
return the instrument to us free of charge for proper environment friendly disposal. You
can obtain further information from your local Narda Sales Partner or by visiting our
website at www.narda-sts.it .
Warning, danger of electric shock
Earth
Read carefully the Operating Manual and its
instructions, pay attention to the safety symbols.
Unit Earth Connection
Earth Protection
Equipotential
KEY TO THE SYMBOLS USED IN THIS DOCUMENT:
DANGER
The DANGER sign draws attention to a potential risk to a person’s safety.
All the precautions must be fully understood and applied before
proceeding.
WARNING
The WARNING sign draws attention to a potential risk of damage to the
apparatus or loss of data. All the precautions must be fully understood
and applied before proceeding.
CAUTION
The CAUTION sign draws attention against unsafe practices for the
apparatus functionality.
NOTE:
The NOTE draw attention to important information.

Contents III
Contents
Page
General safety considerations and instructions ..........……
EC Declaration of Conformity ………..............................……
V
VI
1 General Information
1.1 Documentation.........................................................……..
1.2 Instruction Manual changes......................................……..
1.3 Introduction to PMM 1008..............................................…
1.4 Instrument items............................................................….
1.5 Optional accessories………………………………………….
1.6 Main specifications..................................................……….
1.7 Front panel ...........................................................………
1.8 Rear panel.................................................................……..
Page
1-1
1-1
1-1
1-1
1-1
1-2
1-4
1-5
2 Installation
2.1Introduction....................................................................……
2.2 Initial inspection.............................................................…..
2.3 Packing and unpacking................................................……
2.4 Preparation for use.................................................……….
2.5 Power cable..........................................................…………
2.6 Environment...........................................................………..
2.7 Return for service.......................................................…….
2.8 Equipment cleaning..................................................………
2.9 System installation....................................................………
2.10 Safety Interlock.......................................................………
Page
2-1
2-1
2-1
2-1
2-2
2-2
2-2
2-3
2-3
2-8
3 Operation instructions
3.1 Starting PMM 1008......................................................……..
3.2 Main menu display……………………………………………..
3.2.1 Continuous test mode.............................................……...
3.2.2 Short test mode......................................................………
3.2.3 Executing a test………………………………………………
3.2.4 Manual mode..........................................................………
3.2.5 SET UP menu..................................................….....……..
3.2.6 Setting antenna factor……………………………………….
3.2.7 Error message.........................................................……..
Page
3-1
3-1
3-2
3-4
3-6
3-7
3-8
3-9
3-10
4 References
4.1 References................................................................……...
4.2 Induction coil..............................................................……..
Page
4-1
4-1
5 How to program
5.1 Introduction......................................................................…
5.2 Communication...............................................................…
5.3 Protocol...........................................................................…
5.4 Address.........................................................................…..
5.5 Format.............................................................................…
5.6 PMM1008 Setting commands.......................................…..
5.7 PMM1008 Query commands....................................……...
Page
5-1
5-1
5-1
5-1
5-1
5-2
5-3
6 Firmware Upgrade
6.1 Introduction................................................................………
6.2 System requirements.................................................………
6.3 To install the software................................................………
6.4 Icon of PMM 1008 software............................................…..
6.5 UPGRADE Procedure...................................................……
Page
6-1
6-1
6-1
6-2
6-2

IV Contents
Figures
Figure
1-1
1-2
1-3
2-1
2-2
2-3
4-1
4-2
4-3
PMM 1008............... ..........................................................................................…....
Front panel PMM 1008.......................................................................................…...
Rear panel PMM 1008......................................................................................….....
PMM 1008 with Square loop 1m…………………………………………………………
PMM 1008 with Square loop 1.5m……………………………………………………….
PMM 1008 with Circular loop 40cm……………………………………………………...
Characteristics of the field generated by a square induction coil.......................…...
3dB area of the field generated by a square induction coil.............................….......
3dB area of the field generated by a square induction coil in the orthogonal plane..
Page
1-3
1-4
1-5
2-7
2-7
2-8
4-1
4-2
4-2
Tables
Table
1-1
4-1
4-2
Technical Specifications......................................………………………………………
Continuous field...................................................………………………………………
Short duration......................................................………………………………………
Page
1-2
4-1
4-1

Safety consideration V
SAFETY RECOMMENDATIONS AND INSTRUCTIONS
This product has been designed, produced and tested in Italy, and it left the factory in conditions fully
complying with the current safety standards. To maintain it in safe conditions and ensure correct use,
these general instructions must be fully understood and applied before the product is used.
•This is an industrial instrument for special EMC test purposes and should be installed and operated
by qualified, authorized and trained personnel only.
•High magnetic fields are present around the instrument when used at high currents. It is highly
recommended not to approach the machine when in operation, and especially forbidden for people
with pacemakers or other electromedical devices.
•When the device must be connected permanently, first provide effective grounding;
•If the device must be connected to other equipment or accessories, make sure they are all safely
grounded;
•In case of devices permanently connected to the power supply, and lacking any fuses or other
devices of mains protection, the power line must be equipped with adequate protection
commensurate to the consumption of all the devices connected to it;
•In case of connection of the device to the power mains, make sure before connection that the voltage
selected on the voltage switch and the fuses are adequate for the voltage of the actual mains;
•Devices in Safety Class I, equipped with connection to the power mains by means of cord and plug,
can only be plugged into a socket equipped with a ground wire;
•Any interruption or loosening of the ground wire or of a connecting power cable, inside or outside the
device, will cause a potential risk for the safety of the personnel;
•Ground connections must not be interrupted intentionally;
•To prevent the possible danger of electrocution, do not remove any covers, panels or guards installed
on the device, and refer only to NARDA Service Centers if maintenance should be necessary;
•To maintain adequate protection from fire hazards, replace fuses only with others of the same type
and rating;
•Follow the safety regulations and any additional instructions in this manual to prevent accidents and
damages.
•It is important to create a security zone around the instrument (at least 1.5m) where no one should go
in while the test is in progress.
•Since improper or careless operation could result in an injury risk, these operating instructions make
an essential part of the device and must be available to the operator at all times. The user must
satisfy all safety instructions and warnings.

VI EC Conformity
EC Dec lar at i on o f Co nf or mi t y
In accordance with the Decision 768/2008/EC
Compliant to the Directives: EMC 2014/30/EU, Low Voltage 2014/35/EU, RoHS
2011/65/EU
Also compliant to the ISO/IEC standards 17050-1 and 17050-2
The manufacturer,
NARDA Safety Test Solutions s.r.l. Socio Unico
via Benessea 29/B
17035 Cisano sul Neva (SV) – ITALY
based on the following harmonized European Standards, successfully applied:
Safety: EN 61010-1
(undated reference, applies to all editions)
EMC: EN 61326-1
(undated reference, applies to all editions)
declares, under its sole responsibility, that the product: PMM 1008 Magnetic Field Generator
conforms with the essential requirements of the Low Voltage Directive 2014/35/E
U,
of the EMC Directive 2014/30/EU, and of the RoHS directive 2011/65/EU.
Cisano sul Neva, 24/08/2016 Egon Stocca, General Manager

General Information 1-1
1 - General Information
1.1 Documentation
Enclosed with this manual are:
•a service questionnaire to send back to NARDA in case of equipment
service is needed
•an accessories check list to verify all accessories enclosed in the
packaging.
1.2 Instruction Manual
changes
Instruments manufactured after the printing of this manual may have a
series number prefix not listed on the title page; this indicates that
instruments with different Series Number prefix may be different from those
documented in this manual.
1.3 Introduction to
PMM 1008
PMM 1008 is a magnetic field generator system at power frequency. The
generator is a current generator and the indication of the field is obtained
considering the antenna factor, the system includes the antenna formed by
one coil and the antenna mast.
The correct output current is automatically set and regulated by the
generator.
PMM 1008 is designed to meet all the requirements contained in the EN
61000-4-8 standard and to cover all the levels described in continuos and
short mode.
1.4 Instrument items
PMM 1008 includes the following items:
•Magnetic field generator
•Mains Supply Cable
•Two cables to connect generator to the loop
•RS232 cable
•Hardware Key
•Allen key 5mm
•Allen key 6mm
•User manual.
1.5 Optional accessories
The optional accessories are:
•One generator support with 4 screws;
•Square loop 1m
•Square loop 1.5m
•Square loop 2m
•Circular loop 40cm
•Circular loop 1m
•Rectangular loop 2.6x1m
•Second antenna mast for square loop 1.5m, or 2m, or rectangular loop
2.6x1m
All Loops are supplied with Support, Mast, and Cart.
Document 1008EN-00519-1.27 - © NARDA 2020

1-2 General Information
1.6 Main specifications Table 1-1 lists the PMM 1008 performance specifications.
The following conditions apply to all specifications:
•The ambient temperature shall be 10° to 40° C.
TABLE 1-1 Technical specifications
Frequency
Range
Remote control
System interface
Connector
User port
Display
Power supply
AC
Max current
Output voltage
Without load
Output current
Max continuos
Max short
Modes
Continuous
Short
Manual
Ramp
Internal timer
Continuous mode
Short mode
Timer resolution
Continuous mode
Short mode
Size
Generator
Loop
Truck
Mast antenna
Cables
Weight
Generator
Loop
Truck
50/60 Hz
RS-232/485
DB9
Two function: - HD Key
- Interlock
4 lines LCD 20 characters
230 VAC±10%,
16 A
Max 4Vac
170 A
1200 A
1-12000 min.
1-5 sec.
1 min
1 sec.
365 x 200 x 480 mm (WxHxD)
1030 x 35 x 1030 mm (WxHxD)
550 x 210 x 650 mm (WxHxD)
1900 mm (H)
95 mm
2
1.5 mm
28 Kg
6 Kg
25 Kg

General Information 1-3
Fig. 1-1 PMM 1008

1-4 General Information
1.7 Front panel
Fig. 1-2 Front Panel
Legend:
- 1.- LCD display
- 2 - Functional keys
- 3 - Operate led
- 4 - Stand-by led
1
2
3
4

General Information 1-5
1.8 Rear panel
Fig. 1-3 Rear Panel
Legend:
- 1.- Mains plug IEC/CEE22
- 2 - power switch
- 3 - RS232/485 interface DB9
- 4 - User I/O port DB15
- 5 - current output connector ø14 mm bolt
5
3 1
2
4

1-6 General Information
This page has been left blank intentionally

Installation 2-1
2 - Installation
2.1 Introduction
2.2 Initial inspection
WARNING
2.3 Packing and
Unpacking
2.4 Preparation for use
WARNING
WARNING
This section provides the information needed to install your PMM 1008.
Included is information pertinent to initial inspection, power requirements,
line voltage , power cables, interconnection, environment, instrument
mounting, cleaning, storage and shipment.
To avoid hazardous electrical shock, do not turn on the instrument
when there are signs of shipping damage to any portion of it.
Inspect the shipping container for damage.
If the shipping container or cushion material is damaged, it should be kept
until the contents of the shipment have been checked for completeness
and the instrument has been checked mechanically and electrically.
Verify the accessories availability in the shipping referring to the
accessories check list enclosed with the Users Manual.
Notify any damage to the carrier personnel as well as the NARDA
Representative.
This is a Safety Class I equipment, it is provided with a protective
earth terminal. An uninterruptible safety earth ground must be
provided from the main power source to the product input wiring
terminals through the power cable (or supplied power cable set).
Verify the safety earth ground functionality before operation.
Before connecting this instrument, ensure that an uninterruptible
safety earth ground is provided from the main power source to the
product protective earth connection. If this instrument is to be
connected to other equipment or accessories, prior to energizing
either unit verify that a common ground exists between them.
Any interruption or loosening of the protective earth ground
conductor, either inside or outside the unit or in an extension cable
will cause a potential shock hazard that could result in personal
injury.
Document 1008EN-00519-1.27 - © NARDA 2020

2-2 Installation
2.5 Power cable
This instrument is equipped with a three wires power cable. When
connected to an appropriate AC power receptacle, this cable grounds the
instrument chassis.
2.6 Environment The operating environment is specified to be within the following limitations:
•Temperature
•Humidity
•Altitude
+10° to +40° C
80% (31°) ÷ 50% (40°)
< 4000 meters
The instrument should be stored in a clean, dry environment
The storage and shipping environment is specified to be within the following
limitations:
•Temperature
•Humidity
•Altitude
-40° to + 50° C
< 95% relative
< 15000 meters
2.7 Return for service If the instrument should be returned to NARDA for service, please complete
the service questionnaire enclosed with the Users Manual and attach it to
the instrument.
To minimize the repair time, be as specific as possible when describing the
failure. If the failure only occurs under certain conditions, explain how to
duplicate the failure.
If possible, reuse of the original packaging to ship the equipment is
preferable.
In case other package should be used, ensure to wrap the instrument in
heavy paper or plastic.
Use a strong shipping container and use enough shock absorbing material
around all sides of the equipment to provide a firm cushion and prevent
movement in the container.
To prevent damage during shipment in particular protect the front panel.
Seal the shipping container securely.
Mark the shipping container FRAGILE to encourage careful handling.

Installation 2-3
2.8 Equipment cleaning
Use a non abrasive clean, soft and dry cloth for equipment cleaning.
To clean the equipment do not use any solvent, thinner, turpentine,
acid, acetone or similar matter to avoid damage to external enclosure.
2.9 System Installation
PMM 1008 is a system with different parts and an installation needing.
To install the PMM 1008 following the steps indicated:
1) Connect the cables to the loop using the screws as shown in the next
figure
2) Position the loop into the teflon support as shown in the next figure

2-4 Installation
3) Lock the loop to the support using the six screws

Installation 2-5
4) Lock the antenna mast on the Cart using the screw on the bottom

2-6 Installation
5) Put the generator support on the Cart and the loop support on the mast
in the position desired using the screw mounted on the support. The final
mounting should be the following:
6) Put the generator on his support on the Cart
7) Connect the cables from the loop to the output current connector in the
PMM 1008 generator rear panel.
8) Insert HD Key on the USER PORT Connector (rear panel)

Installation 2-7
WARNING
The antenna produces magnetic field, the field is high in the center of
the loop, set the generator positioning outside of the loop like in the
previous figure.
Fig. 2-1 PMM 1008 with Square loop 1m
Fig. 2-2 PMM 1008 with Square loop 1.5m

2-8 Installation
Fig. 2-3 PMM 1008 with Circular loop 40cm
2.10 Safety Interlock
WARNING
The PMM 1008 is provided by a safety interlock connected at user port on
the rear panel. The connections are the following
To use the PMM 1008, is necessary to insert the HD Key
The interlock can be used to insert an external safety switch like in the
following draw:
Table of contents
Popular Portable Generator manuals by other brands

Power Tech Generators
Power Tech Generators PTSMH-15 Operator's manual

Firman
Firman WH03041 owner's manual

Saint Productions
Saint Productions SP2000 product manual

Briggs & Stratton
Briggs & Stratton 1970 owner's manual

VICI DBS
VICI DBS HK PLUS Series user manual

Winco
Winco WT3000H Installation and operator's manual

Isotronic
Isotronic 78405 Instructions for use

Winco
Winco DR45F4/1 Installation & operator's manual

Ingersoll-Rand
Ingersoll-Rand G 220 Users guide and maintenance manual

Powermate
Powermate PMC505622 manual

SDMO
SDMO Technic 7500 TE C Instruction and maintenance manual

Clarke
Clarke IG1700F Operation & maintenance instructions