manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. national-spencer
  6. •
  7. Water Pump
  8. •
  9. national-spencer 7019 User manual

national-spencer 7019 User manual

MODEL: 7019
4
ASSEMBLY DIAGRAM
U.S. Design patent 29/501,301
Design patent EU 002530402-0001
※ Read all instructions and precautions before use.
INSTRUCTIONS AND PRECAUTIONS
BATTERY OPERATED PUMP
NO
1
2
3
4
5
6
7
8
9
10
10-1
10-2
10-3
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53-1
53-2
54
55
56
RAW MAT`L
PP
PP
POM
PP
STAINLESS STEEL(SUS 304)
M4x10
Φ3, RED
CEM
10kΩ
5A
VITON
STAINLESS STEEL(SUS 304)
POM
NBR
PP
STAINLESS STEEL(SUS 304)
VITON
PE
VITON
PE
PE
POM
VITON
VITON
POM
ZDC
POM
STAINLESS STEEL(SUS 304)
POM
VITON
PP
PP
STAINLESS STEEL(SUS 304)
PE
PP
PP
STAINLESS STEEL(SUS 304)
POM
VITON
VITON
PP
STAINLESS STEEL(SUS304)
VITON
PP
M4x10
PA
PP
M4x15
PVC
BRONZE
PP
DC19.2V Ni-Cade
PP
Q`TY
1
1
1
1
1
6
1
1
1
1
1
2
1
2
2
2
2
1
1
1
1
1
1
1
1
1
1
2
1
1
1
1
1
1
1
3
2
3
2
1
1
1
1
1
1
1
1
1
1
1
1
1
1
2
1
2
1
1
1
1
FRONT COVER
BACK COVER
NOZZLE HOLDER
HOLDER COVER
NOZZLE HOOK
SCREW
TOGGLE SWITCH
WATERPROOF CAP
LED LAMP
PCB ASS`Y
RESISTOR
FUSE HOLDER
FUSE
CONNECTOR WIRE
CONNECTER PIN
MOTOR WIRE PACKING
WIRE CLAMP
BODY
O-RING(BODY)
DRUM BUNG ADPTER
INNER PIPE
SUCTION PIPE PACKING
SUCTION PIPE(UPPER)
O-RING(PIPE)
SUCTION PIPE(LOWER)
MOTOR WIRE
MOTOR COVER
O-RING(MOTOR COVER, HANDLE)
MOTOR
MOTOR PACKING
MOTOR CASE
IMPELLER
IMPELLER CASING
FILTER
END CAP
O-RING
(HOSE ADAPTER, SPOUT ADAPTER)
HOSE ADAPTER
JOINT NUT
HOSE CLAMP
DISCHARGE HOSE
HANDLE
NOZZLE CAP
NOZZLE SPRING
NOZZLE PISTON
O-RING(PISTON L)
O-RING(PISTON S)
NOZZLE LEVER
SPOUT
O-RING(SPOUT)
SPOUT ADAPTER
SCREW
CABLE CLAMP
BATTERY ADAPTER
SCREW
CABLE CONNECTER
TERMINAL
TERMINAL BRACKET
CHARGER
BATTERY
BUTTRESS ADAPTER
PART NAME
54 55 56
Precautions for Use
Names of Parts
Specications (MODEL: 7019)
Directions for Use
4
7
5
3
6
9
10 12
2
8
1
DANGER WARNING CAUTION
CAUTIONDANGER WARNING
5A
Operating temperature
Operating voltage DC19.2V
Approx. 28liters (7 Gallons) at Water
Approx. 850 ~ 1245mm (33.5”~ 49”)
Approx. 2m (6.6ft)
Delivery volume
Suction pipe length
Discharge hose length
Applicable liquids
Fuse
+5˚C ~ 40˚C (41˚F ~ 104˚F)
Diesel, DEF(AdBlue), Water, Kerosene, Antifreeze, Windshield washer uid,
Mild detergents, Agricultural chemicals, Light oils.
Toggle Switch Nozzle holder
Battery adapter
Nozzle
Drum bung adapter
Suction pipe
Discharge hose
Operating lamp(LED)
Adjustment nut
11
If the directions of this sign are not
followed, fatal accidents can happen and
the user may die or get seriously injured.
Do not use for ammable liquids or
concentrated acids.
Be cautious. This pump does not
have an explosion proof motor.
Do not use near the ammable
materials such as gasoline, gas, etc.
Only use on applicable liquids
written on the specications.
These instructions are to ensure the product is used correctly, safely, and to prevent any possible risk or damage to the user
and/or others people. Our company shall not take any responsibility for any failure of product, malfunction and damages
caused by improper use by the user or third parties.
Make sure the pump is tightly
secured to the drum(tank) before
turning the pump on.
Do not refuel directly while the
vehicle or equipment is turned on.
Do not leave the pump unattended.
Make sure to use the pump on even
surface.
Do not allow children to operate the
product without adult supervision.
After using the pump, do not keep it
on its side or upside down.
Make sure to remove any left-over liquid
in the discharge hose after each use.
Do not alter or disassemble the ump.
Do not run the pump ‘dry’ or let the
pump idle without transferring.
Make sure to turn o the power after
using the pump.
Do not shock the pump.
Do not use deteriorated or
contaminated liquids and fuels.
Do not place the pump in a wet area.
Do not use this pump for hot liquids
above 40°C (104°F ).
The included 19.2V Ni-Cade battery
charged with about 80% from the
factory and need to discharge
completely each time before
recharging to get it’s full capability.
Recharging before the battery
completely discharged will shorten its
charge and cannot be returned to its
original storage capacity.
If the directions of this sign are not
followed, accidents can happen or
the user can get injured.
If the directions of this sign are not
followed, the product can get damaged
or the user can get injured.
Adjust the length of the suction pipe
to t the drum (tank).
Insert the suction pipe into the
drum (tank).
Tighten the drum bung adapter.
Connect the 19.2V battery into the
battery adapter.
Place the nozzle into the receiving
container to transfer liquid.
Toggle switch ON(Up).
Pull the nozzle lever and start
supplying the liquid.
Release the lever when the liquid
supply is completed.
Toggle switch OFF(Down).
Pulling the lever of the nozzle,
lift it up.
Let the left-over liquid in the hose
ow back into the drum (tank).
Insert the nozzle in the nozzle holder
for storage.
2 3
Charger
19.2V Ni-Cade battery
Buttress adapter

Popular Water Pump manuals by other brands

Ulvac MS120A instruction manual

Ulvac

Ulvac MS120A instruction manual

Gardena 4000/5 eco operating instructions

Gardena

Gardena 4000/5 eco operating instructions

KRAL CG Series operating instructions

KRAL

KRAL CG Series operating instructions

Grundfos HYDRO MPC instructions

Grundfos

Grundfos HYDRO MPC instructions

moyno 2000 Service manual

moyno

moyno 2000 Service manual

EINHELL ROYAL HW 1300 Niro/Niro operating instructions

EINHELL

EINHELL ROYAL HW 1300 Niro/Niro operating instructions

WACKER Group PT 6LT Operator's manual

WACKER Group

WACKER Group PT 6LT Operator's manual

Wilo Wilo-Jet-WJ Installation and operating instructions

Wilo

Wilo Wilo-Jet-WJ Installation and operating instructions

Tetra 325 GPH quick start guide

Tetra

Tetra 325 GPH quick start guide

aquate 1350 Series Installation and operating manual

aquate

aquate 1350 Series Installation and operating manual

ENMET 145 manual

ENMET

ENMET 145 manual

Eckerle EE 400M installation instructions

Eckerle

Eckerle EE 400M installation instructions

SATA HKU 60 operating instructions

SATA

SATA HKU 60 operating instructions

Etatron eOne quick start guide

Etatron

Etatron eOne quick start guide

Lincoln industrial A Series Operator's manual

Lincoln industrial

Lincoln industrial A Series Operator's manual

Crown G6 Installation and operation manual

Crown

Crown G6 Installation and operation manual

Bredel Hose pump Series manual

Bredel

Bredel Hose pump Series manual

Ulvac VPC-051 user manual

Ulvac

Ulvac VPC-051 user manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.