NAVIS W410 Series User manual

W410 DISPLAY UNIT
MANUAL
Models: W410/D, W410XB/D, W410XW/D, W410XL/D
PREFACE
Thank you for purchasing the Navis anemometer. This manual provides information for the best performance and safe application of
the anemometer display unit. This manual does not cover the anemometer sensors for which the manuals will come separately.
Read this manual carefully before starting the installation. Keep this manual after installation for future reference.
INTRODUCTION
W410 models are long-range display units which receive data from NAVIS wind sensors, display various wind data and use internal
and external alarms for warnings about excess wind speed. Smartphone compatibility (W410XB/D, W410XL/D models) allows real-time
wind data monitoring on smartphones or tablets. Wi-Fi compatibility (W410XW/D, W410XL/D models) allows real-time wind data
monitoring on “Navis Live Data” web interface. 4-20 mA output (W410XB/D, W410XW/D and W410XL/D models) allows connection to
external devices. Various wind data can be stored on SD card (W410XL/D model).
1. Display
2. Red and Yellow alarm lights
3. Keys
4. Relays signal lights
5. Buzzer
6. SMA antenna connector
7. SD card insertion
Figure 1. (W410 display unit –front panel)
The W410 display is compatible with NAVIS sensors: WS 010-1 (wind speed sensor, standard range), WS 011-1 (wind speed sensor,
extended range), WSD 010-1 (wind speed/direction sensor, standard range), WSD 011-1 (wind speed/direction sensor, extended
range), WS 011-1-EX (wind speed sensor for explosive environments), WSD 011-1-EX (wind speed/direction sensor for explosive
environments).
MOUNTING
Select the position where the signal reception is strong enough under all conditions. Use remote antenna if necessary.
Display unit can be mounted onto the ferrous surface with four mounting magnets (optional accessories) or with mounting screws (not
enclosed) to any flat surface.
Mounting the display unit with screws:
Unscrew all 4 plastic screws and remove the front panel. Note that the screws can be pulled out only at the correct angle. Place the
rear panel of the display unit to the final mounting position and mark the position for the bores. Remove the casing and drill holes for
the mounting screws. Place the rear panel of the display unit in position and tighten the mounting screws. Attach the front panel of the
display unit with 4 plastic screws.
ANTENNA CONNECTION
Connect the enclosed antenna to the SMA connector on the display unit only when the power supply is switched OFF.
OPERATION
If the display unit is delivered as a set, with the sensor included, the correct sensor address is already set.
Otherwise please set the correspondent sensor address first. Check the address settings procedure in the chapter “SETTINGS”.
Turn the sensor ON by rotating the sensor cups (see sensor user manual).
Fresh wind data are received every two seconds. If data are not received for more than 30 seconds, the “No data” notification appears
on the display.

WIRING
Please note! Switch off the power before connecting the power supply to the display unit.
Unscrew all 4 plastic screws and remove the front panel. Connect the 12-24 V DC power supply. For using external alarm devices,
connect them to the relay connection terminals. For using 4-20mA outputs (only at W410XB/D, W410XW/D and W410XL/D models),
connect the connection terminals to external devices. Place the front panel into position and tighten the screws. Do not use excessive
force to plastic screws. Switch ON the power supply and check the operation.
Figure 2. Figure 3. Figure 4.
(W410 display unit - rear panel) (wiring connection for W410/D model) (wiring connection for W410XB/D,
W410XW/D and W410XL/D models)
DISPLAY
Switching between pages:
With short presses of the HIST key you can open pages 2 and 3 to see the wind speed and “Max alarm”history respectively.
The display will return to the first page by holding down the HIST key for 3 seconds or automatically after 1 minutes of inactivity.
1st page:
1. Current wind speed
2. Current wind speed bar graph
(set max alarm level is always on ¾ bar height)
3. Peak wind speed in the last 2 minutes bar graph
(set max alarm level is always on ¾ bar height)
4. 10 seconds average wind direction indicator (only at WSD sensor)
5. Unit of wind speed measurement
6. Temperature at sensor
7. Max Alarm value
8. Pre alarm value
9. Status bar (received data package indicator, signal strength value (in dB), Figure 5. (Display –1st page)
current time, SD card indicator, sound alarm ON/OFF indicator)
2st page:
8-hour peak wind speed history graph.
Each column represents peak wind speed during the 5-minutes interval
3st page:
8-hour “Max alarm”history graph with 5-minutes intervals Figure 6. (Display –2nd page) Figure 7. (Display –3rd page)
SIGNAL RECEPTION
The reception symbol blinks when the display unit receives a signal from the sensor (every 2 seconds if the reception is good).
Signal strength is numerically shown in dB:
•-105 dB is approximately the limit where display unit stops receiving
• -100 dB and lower means very week signal
• -95 ... -90 dB is considered as still acceptable
• -85 dB and higher is a good signal
When the sensor doesn't send data (in the OFF state) or when the signal is lost for a more than 30 seconds, the “No data” notification
appears on the display, indicating that the display unit doesn’t receive data from the sensor (sensor OFF or out of range).
RANGE
Connection between the sensor and display unit works on a free 868 MHz band. The range is up to 500 meters (1300 meters with an
extended range sensor) when the sensor is mounted at a height of 10 meters and when there is no obstacle between the sensor and
the display unit. Inside buildings the range is much smaller. Normally the signal can be received through two to three walls.
ALARMS
The alarms consist of internal signalization (red and yellow alarm lights + sound signal) and four relays which control optional external
alarm devices.
Relays 1, 2 and 3 are dedicated to wind speed alerts. Relay 4 can be set for alerting that the display unit has no data from the sensor
or as 2-zone wind direction alarm.
OPERATION OF ALARMS
Pre-alarm 1: when set value is exceeded, relay 3 will activate.
Pre-alarm 2: when set value is exceeded, relay 2 will activate, the yellow light will start blinking, and the buzzer will sound with short
interruptions.
Max alarm: when set value is exceeded, relay 1 will activate, the red light will flash, and the buzzer will sound continuously.
No Signal / Wind Direction Alarm: if there is no data received from sensor or set wind direction value is exceeded, relay 4 will activate.
SOUND ALARM
By holding-down the upper key for 2 seconds you can switch the sound alarm ON and OFF.
The sound alarm is active each time the display unit is turned ON.
In the settings menu, the sound alarm can be disabled permanently.

BATTERY REPLACEMENT
Notification “Sensor battery low” on LCD indicates the empty state of sensor battery. Please replace sensor battery according to sensor
user manual.
If time and date of display unit set to default value check the battery for real time clock battery back-up (1 x 3 V CR2032) and replace it
if needed:
unscrew all 4 plastic screws to open display unit enclosure. Note that the screws can be pulled out only at the correct angle.
Disconnect main power supply. Replace the battery for real time clock battery back-up (1 x 3 V CR2032). Connect main power supply.
Reattach the front panel of the display unit.
RESET OF DISPLAY UNIT
With upper button pressed at power ON, RESET is performed (all settings except »Sensor Address«, »WS Cal. Factor« and »WD
Cal.« go to default values).
TROUBLESHOOTING
Symptom
Action
The display unit cannot read the
sensor
(“No data” appears on the display)
- check if the correct sensor address is set on the display unit
- make sure the sensor is not in sleep mode (turn the cups to wake up the sensor)
- check the sensor battery –replace the battery if needed
- check the operation at a reduced distance to the display unit
Interrupting and weak sensor signal
- check for obstructions between sensor and display unit
- place the sensor or display unit in a different position with better signal reception
- reduce distance to the display unit
- change or add antenna for the display unit
Unresponsive display unit
- check 1 x 3 V CR2032 Lithium battery in display unit –replace the battery if needed
- remove 1 x 3 V CR2032 Lithium battery and main power supply for 1 minute to reset
display unit.
Time and date set to default value
- check the battery for real time clock battery back-up (1 x 3 V CR2032) - replace if needed
APPLICABLE ONLY FOR W410XB/D AND W410XL/D MODELS:
SMARTPHONE COMPATIBILITY
A data packet is transmitted over Bluetooth every second. With the free “Windy Anemometer” application you can read the data of the
current, average, and maximum wind speed, as well as wind direction and temperature, or view history graphs on your smartphone.
In the application settings menu, always set the address corresponding to the address of the W410 receiving sensor.
The range is up to 40 meters. Inside a building, the range is much smaller. The range also varies with the type of smartphone or tablet.
Application “WINDY ANEMOMETER” can be downloaded from Google Play or Apple Store.
Android: Applications requires device with Android 4.3 or newer with Bluetooth Low Energy (BLE).
Apple: In iOS settings for the Windy Anemometer application configure parameter "Allow Location Access" to "While Using the App".
APPLICABLE ONLY FOR W410XW/D AND W410XL/D MODELS:
WI-FI COMPATIBILITY
When display unit receive data from wind sensor, data packet is transmitted through Wi-Fi connection to “Navis Live Data” web
interface. On Navis “Live Data” web interface it can be observed data of current, average and maximum wind speed, wind direction,
temperature or view history graphs.
NAVIS LIVE DATA WEB INTERFACE
For registering display unit to Navis “Live Data” web interface please see “Navis Live Data” web interface user manual.
SETTINGS: WI-FI PARAMETERS
PARAMETER: Scan for Wi-Fi
To search nearby Wi-Fi networks select parameter “Scan for Wi-Fi”.
If there are Wi-Fi networks available use UP, DOWN and SET keys to select desire Wi-Fi.
For enter password use UP and DOWN keys for select individual character and SET key to confirm selected character.
After entering password, confirm with OK.
If there is no password, leave input field blank and confirm with OK.
PARAMETER: Wi-Fi
For manual entry of Wi-Fi network SSID select parameter “Wi-Fi” and use UP and DOWN keys for selecting individual character and
SET key to confirm selected character. After entering Wi-Fi network SSID, confirm with OK.
For enter password use UP and DOWN keys for select individual character and SET key to confirm selected character.
After entering password, confirm with OK.
If there is no password, leave input field blank and confirm with OK.
SERIAL NUMBER
S/N parameter show Wi-Fi serial number of display unit.
“WI-FI” ICON
Display unit is connected to WiFi network when “WiFi” icon is displayed on main screen.
Display unit sent data to Navis “Live Data” portal when “WiFi” icon blinks on main screen.
If there is no “WiFi” icon displayed on main screen please check your Wi-Fi connection or Wi-Fi parameters of display unit.

APPLICABLE ONLY FOR W410XL/D MODEL:
STORING TO SD CARD
Data in .txt format are stored to SD card every full hour. Each data has date and time stamp.
Logging interval is selectable from 10 sec to 1h. Data are stored in the .txt format and are suitable for processing in programs for
working whit spreadsheet (Excel, Open office, etc...).
Mark “NA” in logged data present missed wind data for marked interval.
Mark “nW” in logged wind direction data present undefined wind direction caused of no wind speed.
There is a rare possibility that individual logged packets could be corrupt due to external causes.
It is recommended to eliminate them during processing logged data.
For each using of new type SD card it is recommended to test writing data to SD card.
STORE DATA FROM SD CARD
It is recommended to store data from SD card every month for preventing data loss because of empty battery in receiver or other
external factors.
DESCRIPTION OF DATA STORED ON SD CARD
[WS]: average wind speed in selected units and logging interval
[WSm]: maximum wind speed in selected units and logging interval
[WSt]: average temperature in selected units and selected logging interval
[WD]: average wind direction in selected logging interval
[RSSI]: average signal strength in selected logging interval
[dd/mm/yyyy]: day/month/year of created logged data
[hh:mm:ss]: hours:minutes:seconds of created logged data
EXAMPLE OF DATA STORED ON SD CARD
Example of logged first 10 wind data from WSD sensor in 10s logging interval. Average [WS] and maximum [WSm] wind speed data
are in units of m/s, temperature in degrees of Celsius [WSt], wind direction [WD] in degrees and signal strength [RSSI] in dB.
<------Navis Elektronika W410 v010119------->
<------------------------------------------->
<Logging Interval:10s----------------------->
<WS[m/s]-WSm[m/s]-WSt[C]-WD[deg]-RSSI[-dB]-->
<n/a[Data not available] nW[No wind present]>
dd/mm/yyyy,hh:mm:ss, WS, WSm, WSt, WD, RSSI
17/10/2016,00:00:10, 0.9, 0.9, 7,184, 65
17/10/2016,00:00:20, 0.8, 0.9, 7,190, 63
17/10/2016,00:00:30, 0.9, 0.9, 7,187, 65
17/10/2016,00:00:40, 0.8, 0.8, 7,189, 66
17/10/2016,00:00:50, 0.7, 0.8, 7,185, 64
17/10/2016,00:01:00, 0.7, 0.7, 7,190, 64
17/10/2016,00:01:10, 0.6, 0.7, 7,184, 65
17/10/2016,00:01:20, 0.0, 0.0, 7, nW, 63
17/10/2016,00:01:30, 0.6, 0.7, 7,186, 63
17/10/2016,00:01:40, 0.6, 0.7, 7,189, 65

SETTINGS: SETTINGS PROCEDURE
1. Hold down the SET key to enter the settings menu. If password protection is active, enter the correct password. The group of
settings displays on the display.
2. Select the group by using the up and down keys and press the SET key to view the selected group.
3. Using the up and down keys select the parameter you wish to adjust and press the SET key to view the selected parameter. The
adjustable parameter blinks.
4. With the up and down keys, adjust the parameter value. Press SET to enter the new value and move to the next parameter.
5. Exiting the settings menu: hold down the SET key to move back one level.
The anemometer also returns to the main screen after 2 minutes of inactivity.
SETTINGS: SETTINGS LIST
Max Alarm
select to set Max Alarm parameters
Pre Alarm 2
select to set Pre Alarm 2 parameters
Pre Alarm 1
select to set Pre Alarm 1 parameters
No Signal/WD alarm
select to set No Signal or Wind Direction alarm parameters
General
select to set general parameters
Wi-Fi*
select to set Wi-Fi parameters
* applicable only for W410XW/D and W410XL/D models
SD Logging*
select to set SD Logging parameters
* applicable only for W410XL/D model
Settings: Max Alarm (Relay 1, RED ALARM LIGHT, continuous sound)
Factory preset:
Setting range:
Description:
Wind Speed:
72 km/h
1 - 50 m/s
Max Alarm limit
ON Delay:
0 s
0 - 600 s
Minimum time of excess wind speed to activate the Max alarm
OFF Delay:
0 min
0 - 60 min
Alarm switch OFF delay after wind speed drops below preset level
Relay:
Normal
Normal/Inverted
Inverted operation of relay
Settings: Pre Alarm 2 (Relay 2, YELOW ALARM LIGHT, interrupted sound)
Factory preset:
Setting range:
Description:
Wind Speed:
52 km/h
1 - 50 m/s
Pre Alarm 2 limit
ON Delay:
0 s
0 - 600 s
Minimum time of exceed Wind speed to activate the Pre Alarm 2
OFF Delay:
0 min
0 - 60 min
Alarm switch OFF delay after wind speed drop below preset level
Relay:
Normal
Normal/Inverted
Inverted operation of relay
Settings: Pre Alarm 1 (Relay 3)
Factory preset:
Setting range:
Description:
Wind Speed:
42 km/h
1 - 50 m/s
Pre Alarm 1 limit
ON Delay:
0 s
0 - 600 s
Minimum time of exceed Wind speed to activate the Pre Alarm 1
OFF Delay:
0 min
0 - 60 min
Alarm switch OFF delay after wind speed drop below preset level
Relay:
Normal
Normal/Inverted
Inverted operation of relay
Settings: No Signal / Wind Direction Alarm (Relay 4)
Factory preset:
Setting range:
Description:
Alarm:
No Signal
No Signal/Direction
Type of Alarm: No signal alarm or wind direction alarm
Relay:
Normal
Normal/Inverted
Inverted operation of relay
Zone1:
From 3150to 450*
00 - 3590
Zone of wind direction alarm ON. *In clockwise direction.
Zone2:
From 1350to2250 *
00 - 3590
Zone of wind direction alarm ON. *In clockwise direction.
ON Delay:
0 s
0 - 600 s
Minimum time of wind direction inside the alarm zone to activate the alarm
OFF Delay:
0 min
0 - 60 min
Alarm switch OFF delay after wind direction leaves the alarm zone
Settings: General
Factory preset:
Setting range:
Description:
Sensor Address:
Enclosed sensor
1 - 255
Set the sensor address of wind sensor
WS Averaging:
2 s
2, 10 or 30 s
Averaging period for displayed wind speed
WS units:
km/h
m/s, km/h, mph, knot
Unit for displaying wind speed
Temperature units:
0C
0C or 0F
Unit for displaying Temperature
20 mA Output*
180 km/h
10 - 50 m/s
Wind speed at 20 mA output
4 mA = 0 km/h
20 mA = set wind speed value
* applicable only for W410XB/D, W410XW/D and W410XL/D models
Password:
NO
NO /
YES - 0000 to 9999
Activation of password protection and setting the password
Sound Alarm:
ON
ON/OFF
Switching sound alarm ON and OFF
Language:
English
English/French
Language selection
WS Cal. Factor
+0,0%
Calibration factor for wind speed (-15,0 ...+15,0% in 0,5% steps)
WD Cal.:
0°
-180°… +180°
Calibration angle for wind direction (-180°...+180°in 1°steps)
Bluetooth*
ON
ON/OFF
Power ON/OFF Bluetooth transmitter
* applicable only for W410XB/D and W410XL/D models
Settings: Wi-Fi (applicable only for W410XW/D and W410XL/D models)
Factory preset:
Setting range:
Description:
Scan for Wi-Fi:
Scan for nearby Wi-Fi
Wi-Fi:
Enter Wi-Fi network manually
S/N
Wi-Fi serial number of display unit
Settings: SD Logging (applicable only for W410XL/D model)
Factory preset:
Setting range:
Description:
Time:
01:58
00.00 –23.59
Time setting - 24 h time format
Date:
01/01/2019
Date setting - day/month/year
Logging int:
1 min
10 s, 1 min, 10 min,
60 min
Selectable SD logging interval

TECHNICAL DATA
Wind speed measurement range: 0,6 - 50,0 m/s
Wind direction measurement range: 0°- 359°
Temperature measurement range: -30....+60 °C
Wind speed units: m/s, km/h, knots, mph
Temperature units: °C, °F
Wind speed averaging period: selectable 2 s, 10 s, 30 s
Wind direction averaging period: 10 s
Wind speed resolution: 0,1 m/s
Wind direction resolution: 1 0
Temperature resolution: 1 0C
Wind speed accuracy: typ. +/- 2,5 %
Wind direction accuracy: +/- 2,5°
Temperature accuracy: +/- 1°C
Operating voltage: 12-24 V DC
Power consumption: max 500 mA
Operating range: with standard range sensor up to 500 m
with extended range sensor up to 1300 m
with connected Yagi antenna 3 - 5 x nominal range
Operating Frequency: 868 MHz
Temperature operating range: -30 ... +60 °C
Relay outputs 4 relay, contact rating 2 A / 24 V
Sound signal (integrated): 85 dB
Antenna input: 50 Ohm, SMA connector
Measuring rate: every 2 sec
Material casing: PC (Polycarbonate)
Dimensions: 130 ×80 ×36 mm
Weight: 320 g
Additional for W410XB/D and W410XL/D models:
Application name on Google Play/Apple Store: WINDY ANEMOMETER
Bluetooth data transmission rate: 1 second
Bluetooth transmission frequency: 2,4 GHz
Bluetooth range: Up to 40 meters. It can varies with type of smart device.
4-20mA outputs: not isolated, common ground with supply
Wind speed: 4 mA = 0 m/s; 20 mA = programmable 10 - 50 m/s
Wind direction: 4 mA = 0°; 20 mA = 359°
Error current: 3,6 mA (if signal from sensor is missing)
Additional for W410XW/D and W410XL/D models:
Navis “Live Data” web interface URL: http://www.navis-livedata.com
Wi-Fi data transmission rate: 2 seconds
Wi-Fi transmission frequency: 2,4 GHz
Wi-Fi range: Up to 20 meters. It can varies with type of Wi-Fi router.
4-20mA outputs: not isolated, common ground with supply
Wind speed: 4 mA = 0 m/s; 20 mA = programmable 10 - 50 m/s
Wind direction: 4 mA = 0°; 20 mA = 359°
Error current: 3,6 mA (if signal from sensor is missing)
Additional for W410XL/D model:
Memory card: micro SD formatted in FAT or FAT32 (recommended). Micro SD included.
Logging interval: selectable 10 s, 1 min, 10 min, 60 min
File creation on SD card: create new file every day at 10 s logging interval
create new file every month at 1 min, 10 min, 60 min logging interval
create new file after each insertion of SD card
create new file after each settings changes
Data format: .txt
Battery: 1 x 3 V CR2032 Lithium (included, pre-inserted)
Subject to technical modification without notice.
ACCESSORIES (optional)
1. Magnetic display mounting assembly
2. External antenna with 3 m cable
3. External Yagi antenna with 3 m cable
4. Spare micro SD card
5. USB / micro SD adapter 1. 2. 3. 4. 5.
WARRANTY (LIMITED)
The warranty period of NAVIS products is one year after the date of purchase. During the limited warranty period any defective
product will be repaired or replaced with a comparable product without charges. The claimed product will be repaired or replaced
only when returned to the store where it was purchased together with original invoice. Failure to follow these instructions may
invalidate the warranty. The limited warranty does not cover the battery or damage of any kind, including physical damage caused
accidentally or misuse of the product. NAVIS does not accept responsibility for any problems which may arise from applications
other than those the product was designed for. Any liability for direct or indirect damage caused by product failure is excluded.
V1 R181019
__________________________________________________________________________________________________________________________________________
This manual suits for next models
4
Table of contents
Other NAVIS Measuring Instrument manuals
Popular Measuring Instrument manuals by other brands

Vega
Vega VEGAMIP R62 operating instructions

ALS
ALS SEC2020 user guide

Agilent Technologies
Agilent Technologies M9302A Service guide

Keysight Technologies
Keysight Technologies B1507A user guide

Hanna Instruments
Hanna Instruments HI 8733 instruction manual

PCB Piezotronics
PCB Piezotronics IMI SENSORS 607A11-0011 Installation and operating manual