Drill two 1/4" (6 mm) dia. holes to a minimum depth of
2.5" (64 mm). Attach projector mount assembly (A)
usingtwo concrete anchors (G),twoflatwashers (E),
and two #14 x 2.5" wood screws (F) as shown in
Illustration A and 1,2,and 3(below). Tightenwood
screws (F) using 3/8" (10 mm) socket wrench until
projector mount assembly (A) is firmly attached.
1
3
Drill hole and insert anchor
Place ceiling plate or mount over anchor and secure
with screw
After repeating step one tighten all fasteners
CUTAWAYVIEW
INCORRECT
concrete
metal
bracket
plaster/
drywall
CORRECT
concrete
metal
bracket
plaster/
drywall
FORDIRECTATTACHMENTTOLOADBEARINGCONCRETE
ONLY!Concrete expansion anchors are not intended for
attachment to concrete ceilings covered with a layer of plaster,
drywall,or other finishing material.If mountingtoconcrete
ceilingcovered with plaster /drywall isunavoidable,plaster /
drywallmustbe counterbored as shownbelow.
concrete
ceiling
F
F
F
Illustration A
Installation to Concrete Ceilings
A
2A
CONCRETECEILING
E
G
G
G
G
FRONTOF
MOUNT
• Do not tighten screws with excessive force.
Overtighteningcancausedamagetomount. Tighten
screws to 40 in. • lb (4.5 N.M.) maximum torque.
CAUTION
• Installer must verify that the ceiling will safely support
thecombined laod of equipmentand allattached
hardwareandcomponents.
WARNING