NEC Video Wall Mount PD02VW MFS 46 55 L Guide

1 of 11 ISSUED: 02-19-13 SHEET #: 145-9018-1
Installation and Assembly:
Full Service Video Wall Mount
Model: PD02VW MFS 46 55 P
Designed for NEC MultiSync® 46” and 55” XUN/V, XS and P Series
Manufactured by Peerless-AV
Max UL Load Capacity:
125 lb (57 kg)

2 of 11 ISSUED: 02-19-13 SHEET #: 145-9018-1
Table of Contents
Parts List.................................................................................................................................................................................3
Installation to Wood Stud Wall................................................................................................................................................4
Installation to Solid Concrete or Cinder Block........................................................................................................................5
Installing Tilt Brackets.............................................................................................................................................................6
Display Adjustment...................................................................................................................................................... 7 and 8
Mounting and Removing Flat Panel Display.............................................................................................................. 9 and 10
NOTE: Read entire instruction sheet before you start installation and assembly.
Tools Needed for Assembly
•stud finder ("edge to edge" stud finder is recommended)
• phillips screwdriver
•drill
• 5/16" (8 mm) bit for concrete and cinder block wall
• 5/32" (4 mm) bit for wood stud wall
• level
• Do not begin to install your product until you have read and understood the instructions and warnings contained in
this Installation Sheet. If you have any questions regarding any of the instructions or warnings, for US customers
please call customer care at 1-800-865-2112, for all international customers, please contact your local distributor.
• This product should only be installed by someone of good mechanical aptitude, has experience with basic building
construction, and fully understands these instructions.
• Make sure that the supporting surface will safely support the combined load of the equipment and all attached
hardware and components.
• Never exceed the Maximum UL Load Capacity. See page one.
• If mounting to wood wall studs, make sure that mounting screws are anchored into the center of the studs. Use of
an "edge to edge" stud finder is highly recommended.
• Always use an assistant or mechanical lifting equipment to safely lift and position equipment.
• Tighten screws firmly, but do not overtighten. Overtightening can damage the items, greatly reducing their holding
power.
• This product is intended for indoor use only. Use of this product outdoors could lead to product failure and personal
injury.
• This product was designed to be installed on the following wall construction only;
WALL CONSTRUCTION HARDWARE REQUIRED
• Wood Stud Included
•Wood Beam Included
•Solid Concrete Included
•Cinder Block Included
• Metal Stud Contact Qualified Professional (not evaluated by UL)
• Brick Contact Qualified Professional (not evaluated by UL)
• Other or unsure? Contact Qualified Professional (not evaluated by UL)
WARNING
Accessories
•RK02 MFS Cable Release Kit
• CK02## Wall Plate Connector Kits

3 of 11 ISSUED: 02-19-13 SHEET #: 145-9018-1
A
BDEF
GHI
JK
PartsList
Description Qty. Part#
ApullͲoutmountassembly 1 145ͲT1668
Badapterbracket2 145ͲT1670
Cmeshsleeve(notshown) 1 600Ͳ1014
DM5x10mmsocketpintypeͲFscrew 2 520Ͳ1164
E#14x2.5"hexheadwoodscrew45S1Ͳ015ͲC03
Fconcreteanchor4 590Ͳ0320
Gfenderwasher4 540Ͳ1008
Hnylonshoulderwasher4 590Ͳ2233
IM6x12mmsocketpinscrew4 520Ͳ1050
JM8x15mmsocketpinscrew4 520Ͳ1068
K4mmallenwrench1 560Ͳ9646
Lcabletie(notshown) 2 560Ͳ9711

4 of 11 ISSUED: 02-19-13 SHEET #: 145-9018-1
EG
WOOD STUD
Installation to Wall Stud
Use a stud finder to locate the edges of the stud. Use of an edge-to-edge stud finder is highly recommended.
Based on their edges, draw a vertical line down the stud center. Place pull-out mount assembly (A) on wall as
a template. Level plate, and mark the center of the four mounting holes. Make sure that the mounting holes are
on the stud center line. Drill four 5/32" (4 mm) dia. holes 2-1/2" (64 mm) deep. Make sure that the pull-out mount
assembly (A) is level, secure it using four #14 x 2.5" wood screws (E) and fender washers (G) as shown below.
• Installer must verify that the supporting surface will safely support the combined load of the equipment and all
attached hardware and components.
• Tighten wood screws so that wall plate is firmly attached, but do not overtighten. Overtightening can damage the
screws, greatly reducing their holding power.
• Never tighten in excess of 80 in. • lb (9 N.M.).
• Make sure that mounting screws are anchored into the center of the stud. The use of an "edge to edge" stud finder
is highly recommended.
• Hardware provided is for attachment of mount through standard thickness drywall or plaster into wood studs. Install-
ers are responsible to provide hardware for other types of mounting situations (not evaluated by UL).
WARNING
1
A

5 of 11 ISSUED: 02-19-13 SHEET #: 145-9018-1
E
F
G
SOLID CONCRETE
CINDER BLOCK
Installation to Solid Concrete or Cinder Block
• When installing wall mounts on cinder block, verify that you have a minimum of 1-3/8" (35 mm) of actual concrete
thickness in the hole to be used for the concrete anchors. Do not drill into mortar joints! Be sure to mount in a solid
part of the block, generally 1" (25 mm) minimum from the side of the block. Cinder block must meet ASTM C-90
specifications. It is suggested that a standard electric drill on slow setting is used to drill the hole instead of a ham-
mer drill to avoid breaking out the back of the hole when entering a void or cavity.
• Concrete must be 2000 psi density minimum. Lighter density concrete may not hold concrete anchor.
• Make sure that the wall will safely support four times the combined load of the equipment and all attached hardware
and components.
WARNING
1
CUTAWAY VIEW
INCORRECT CORRECT
wall
plate wall
plate
plaster/
drywall plaster/
drywall
concrete concrete
1
3
2
F
Drill holes and insert anchors (F).
Place plate (A) over anchors (E) and secure with screws (F).
Tighten all fasteners.
A
F
E
concrete
surface
Make sure that pull-out mount assembly (A) is level,
use it as a template to mark four mounting holes.
Drill four 5/16" (8 mm) dia. holes to a minimum
depth of 2.5" (64 mm). Insert anchors (F) in holes
flush with wall as shown (right). Place pull-out
mount assembly (A) over anchors and secure with
four #14 x 2.5" screws (E), and fender washers (G).
Level, then tighten all fasteners.
• Tighten screws so that wall plate is firmly attached,
but do not overtighten. Overtightening can damage
screws, greatly reducing their holding power.
• Never tighten in excess of 80 in. • lb (9 N.M.).
• Always attach concrete expansion anchors directly
to load-bearing concrete.
• Never attach concrete expansion anchors to
concrete covered with plaster, drywall, or other
finishing material. If mounting to concrete surfaces
covered with a finishing surface is unavoidable,
(not evaluated by UL) the finishing surface must be
counter bored as shown below. Be sure concrete
anchors do not pull away from concrete when
tightening screws. If plaster/drywall is thicker than
5/8" (16 mm), custom fasteners must be supplied
by installer (not evaluated by UL).
WARNING
A

6 of 11 ISSUED: 02-19-13 SHEET #: 145-9018-1
B
B
3
SECURITY SCREW
Attach adapter brackets (B) to display carriage. Slide adapter brackets (B) into position.
Loosely fasten in place using security screw as shown in detail 1.
NOTE: Once display is located in desired position, tighten security screws using 4mm allen wrench (K) to lock in
place.
Attaching Adapter Brackets to Display Carriage
DETAIL 1
Attach adapter brackets (B) to back of display using four M6 x 12 mm socket pin screws (I) with nylon shoulder
washer (H), or four M8 x 15 mm socket pin screws (J) as shown below.
B
HI or J
2
400 mm
300 mm 200 mm
MAX VESA-400 mm
MIN VESA-200 mm
Attaching Adapter Brackets to Display
DISPLAY
DISPLAY CARRIAGE
600 mm

7 of 11 ISSUED: 02-19-13 SHEET #: 145-9018-1
Use legend below to determine position of display.
NOTE: Each knob can be adjusted independently for fine tuning adjustments.
4
Turn knob CLOCKWISE to raise side
Turn knob COUNTER-CLOCKWISE to lower side
UP
ROTATE LEFT ROTATE RIGHT
Pull Out Mount Assembly Adjustment

8 of 11 ISSUED: 02-19-13 SHEET #: 145-9018-1
Use legend below to determine position of display.
NOTE: Each knob can be adjusted independently for fine tuning adjustments.
5
Turn knob CLOCKWISE to move corner toward the wall
Turn knob COUNTER-CLOCKWISE to move corner away from the wall
IN OUT
TILT BACKWARD TILT RIGHT TILT LEFT
TILT FORWARD
Adapter Bracket Adjustment
BACK
BACK
BACKBACK BACK
BACK

9 of 11 ISSUED: 02-19-13 SHEET #: 145-9018-1
6
7Open pull-out mount assembly (A) by releasing locking tab. Push or pull up on locking tab as shown below.
NOTE: Extended position is for service access only. The mount must be closed during normal use and operation.
Open and Close Pull Out Mount Assembly
A
A
Display cables can be routed through top or bottom of pull-out mount assembly (A).
NOTE: Use mesh sleeve (M) and cable ties (L) for cable management.
NOTE: Cable ties and cable management slots on pull-out mount assembly (A) can be used to secure display
cables.
Cable Management
DETAIL 3
CABLE MANAGEMENT
SLOTS
LOCKING TAB
LOCKING TAB
PULL UP
PUSH UP

10 of 11 ISSUED: 02-19-13 SHEET #: 145-9018-1
8Open adapter brackets (B) by pulling down on front release strap while pulling bottom of display away from wall.
NOTE: Once front release strap is pulled, adapter brackets (B) kick stand will engage.
NOTE: Extended position is for service access only. The mount must be closed during normal use and operation.
Open Adapter Brackets
B
B
B
B
BACK RELEASE STRAP
FRONT RELEASE STRAP DISPLAY NOT
SHOWN FOR CLARITY
KICK STAND
Close Adapter Brackets
Slightly pull display away from wall to release kick stand while pulling down on back release straps on adapter brackets
(B) as shown below. Support the display until the adapter brackets (B) are engaged in the closed position.
NOTE: Once back release strap is pulled, adapter brackets (B) kick stand will disengage.
KICK STAND
DISPLAY NOT
SHOWN FOR CLARITY
DISPLAY NOT
SHOWN FOR CLARITY
DISPLAY NOT
SHOWN FOR CLARITY

11 of 11 ISSUED: 02-19-13 SHEET #: 145-9018-1
D
LOCKING TAB
9To prevent locking tabs from releasing, secure using two M5 x 10 mm socket pin type-F screws (D).
Pull-Out Mount Assembly (Optional) Security
Other manuals for Video Wall Mount PD02VW MFS 46 55 L
1
Table of contents
Other NEC Rack & Stand manuals

NEC
NEC Video Wall Mount PD02VW MFS 46 55 L Guide

NEC
NEC N8154-46 User manual

NEC
NEC MultiSync V801 User manual

NEC
NEC PlasmaSync PX-60XM5A User manual

NEC
NEC IW77 User manual

NEC
NEC NP-PH1000U User manual

NEC
NEC PD04VW QR 46 55 User manual

NEC
NEC NP40CM Guide

NEC
NEC MultiSync V461 User manual

NEC
NEC WM-46S-P User manual
Popular Rack & Stand manuals by other brands

Konig & Meyer
Konig & Meyer 14100 manual

WilTec
WilTec VM-P09 installation guide

Wasserstein
Wasserstein Horizontal Adjustable Angle Mount user manual

Forging Mount
Forging Mount FM4545 installation manual

NeoMounts
NeoMounts FPMA-D700DD3 instruction manual

Premier Mounts
Premier Mounts Multi-Monitor with table adapter MMT Specification sheet