Strain relief & cover
Make sure all cables are properly secured
and the protection cover is placed back
over the terminals.
Power ON
Make sure to close the enclosure before
connecting the AC mains.
If powered devices are not working properly
please check if the DC output is 13.2 V.
The DC output can be adjusted with the
Voltage adjuster.
AC mains input
-V +V
Live
(brown)
AC mains
Neutral
(blue)
L N
3 x 0.75 mm², earth connection, max. 2 m
Make sure that the AC mains (230-240 VAC)
is NOT connected!
Shield & earth
-V +V
Shield
AC mains DC output
Earth wire
(green-yellow)
The protective earth wire should be the
last to disconnect in the event of an
inadvertent pull on the power cord.
DC output
1
2
3
-V +V
GND Vin
DC output
2 x 0.5 mm2 shielded, max. 5 m
Remove the protection cover from the
terminals before wiring.
A
B
DC outputAC mains input
Power LED
Voltage adjusterL N -V +V
Protection cover
13 2
5
4
5
Wiring specications
Purpose
A. AC mains input wiring
B. DC output wiring
Specification
3 x 0.75 mm², earth connection, max. 2 m
2 x 0.5 mm2 shielded, max. 5 m
Failure to comply with the wiring specifications may result in
malfunction and/or dangerous situations.
Instructions
Step
1.
2.
3.
4.
5.
DC output
Shield & earth
AC mains input
Strain relief & cover
Power ON
Remarks
Default output is 13.2 V.
Connect shield and earth wire at the same time to the same terminal.
Make sure the AC mains input is still disconnected at this point.
Use the available provisions to secure all cables.
Make sure the protection cover is put back over the terminals.
Before installing or servicing this device
please read and take the ‘Safety precautions’
into account. These can be found on the
backside of this installation guide.
Conductors connected to the screw
terminals must be fitted with a ring,
crimped lugs, etc. so that reliance is not
placed upon the screw alone.
Document information
Date
Version
Part number
March 19, 2020
5
5283507
This information is furnished for guidance, and with no guarantee as to its
accuracy or completeness; its publication conveys no licence under any patent
or other right, nor does the publisher assume liability for any consequence of
its use; specifications and availability of goods mentioned in it are subject to
change without notice; it is not to be reproduced in any way, in whole or in
part, without the written consent of the publisher.
info@nedapsecurity.com
www.nedapsecurity.com
+31 (0) 544 471 111
Nedap Security Management
Parallelweg 2
NL-7141DC Groenlo
The Netherlands
© 2020 Nedap N.V. All rights reserved.
Install movie
Opening enclosure
2
3
4
Tool ø< 5 mm
1
Mounting
60
ø5(3x)
12.5
113.5
19
120
DIN rail 35 x 7.5mm Drill pattern
All dimensions are in millimeters (mm).
Preferred screws: 4.8 x 32 mm (DIN7981)
Certications
This equipment is tested and conforms with the essential requirements of
Electromagnetic Compatibility Directive 2004/108/EC: EN50130-4 (2011), EN55022
(2010) + AC(2011); and Low Voltage Directive 2006/95/EG: EN60950-1 (2006) +
A11(2009) + A1(2010) + A12(2011) + AC(2011) + A2(2013).
LED indication
Colour
Green
Description
DC output active
Power LED (internal)
General
Safety precautions
This equipment should be accessible, installed, operated, serviced, and repaired by qualified personnel
only. The installation and interconnection of this equipment to facility wiring and other equipment must
be done by a competent, qualified craftsperson who is familiar with applicable standards and codes
governing the installation.
Installation methods, practices, or procedures that are unauthorised or done improperly are dangerous
and could result in serious personal injury or damage to property and equipment
Warning
Power Supply: Ensure the source voltage matches the voltage of power supply before turning ON the
power.
Power Cord and Plug: To prevent an electric shock or fire, be sure to use the power cord as described
below:
Maximum 4.5 m long, rated minimum 250 V, 10 A, Type SJT flexible cord. One end terminates with
tandem blade (240V units) grounding, molded-on, attachment plug with a 10 A, 240 V 3-pole
configuration. Cord and plug should have CE approval.
The socket-outlet shall be installed near the equipment and shall be easy accessible.
Fixed Power Connection: In the case of a fixed connection to the mains, a disconnect from mains must
be available near the equipment.
Protective Grounding: The protective grounding terminal must be connected to ground to prevent an
electric shock before turning ON the power.
Fuse: For continued protection against risk of fire replace fuses only with the same type and rating of
fuse.
Before replacing the fuses, turn off the power and disconnect the power source. Do not use a different
fuse or short-circuit the fuse holder.
Do Not Operate Near Flammable Materials: Do not operate the equipment in the presence of flammable
liquids or vapors. Operation of any electrical equipment in such environment constitutes a safety
hazard.
Opening the covers: Do not open the top cover when active since lethal voltages do exist inside. Always
first disconnect from mains supply and make sure maintenance is safe.
Do Not Modify: To be sure of safety, do not modify or add anything to the equipment other than
mentioned in this installation guide or indicated by NEDAP NV.
Technical specications
Dimensions230 x 165 x 65 mm (H x W x D)
WeightApprox. 820 g
Enclosure PC ABS
Temperature range Operation: 0°C to 40°C
Storage: -30°C to 65°C
Relative humidity20% to 90% (non-condensing)
AC mains input230-240 VAC, 50/60 Hz, 1.2 A
DC output13.2 VDC SELV, 4.5 A
AC mains input wiring3 x 0.75 mm², earth connection, max. 2 m
DC output wiring2 x 0.5 mm² shielded, max. 5 m
Safety Class I
AP7021 (9982825)
AEOS Blue
power supply 12V
Installation guide
AP7021

This manual suits for next models

1

Popular Power Supply manuals by other brands

Akyga AK-ND-18 user manual

Akyga

Akyga AK-ND-18 user manual

SilverStone STRIDER GOLD S Series quick start guide

SilverStone

SilverStone STRIDER GOLD S Series quick start guide

TDK-Lambda FPS-S1U instruction manual

TDK-Lambda

TDK-Lambda FPS-S1U instruction manual

Monacor PSS-1005USB instructions

Monacor

Monacor PSS-1005USB instructions

BCP PUOOUBZ How to install

BCP

BCP PUOOUBZ How to install

CIOKS AC Rider link user manual

CIOKS

CIOKS AC Rider link user manual

Keithley Series 2200 user manual

Keithley

Keithley Series 2200 user manual

SECO-LARM EAP-5D1Q manual

SECO-LARM

SECO-LARM EAP-5D1Q manual

Monacor PSS-1200 quick guide

Monacor

Monacor PSS-1200 quick guide

EcoFlow DELTA 2 user manual

EcoFlow

EcoFlow DELTA 2 user manual

Puls Dimersion CP10.481 installation manual

Puls

Puls Dimersion CP10.481 installation manual

Behringer Micropower PS400 user guide

Behringer

Behringer Micropower PS400 user guide

patura p30 user manual

patura

patura p30 user manual

ELC AL 941 instruction manual

ELC

ELC AL 941 instruction manual

Puls MiniLine ML30 instruction manual

Puls

Puls MiniLine ML30 instruction manual

Gallagher 3E0708 Master Series instructions

Gallagher

Gallagher 3E0708 Master Series instructions

Cross Technologies 2000-2 LNB Series instruction manual

Cross Technologies

Cross Technologies 2000-2 LNB Series instruction manual

Vector VEC022 Owner's manual & warranty

Vector

Vector VEC022 Owner's manual & warranty

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.