NEO NAS-CW01W6 User manual

NAS‐CW01W6
深圳市丽欧电子有限公司
Version1.0.3
产品配置
NOTE: This equipment has been tested and found to comply with the limits for a
Class B digital device, pursuant to part 15 of the FCC Rules. These limits are
designed to provide reasonable protection against harmful interference in a
residential installation. This equipment generates uses and can radiate radio
frequency energy and, if not installed and used in accordance with the instructions,
may cause harmful interference to radio communications. However, there isno
guarantee that interference will not occur in a particular installation. If this
equipment does cause harmful interference to radio or television reception, which
can be determined by turning the equipment off and on, the user is encouragedto
try to correct the interference by one or more of the following measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and receiver.
-Connect the equipment into an outlet on a circuit different from that to which the
receiver is connected.
-Consult the dealer or an experienced radio/TV technician for help
Changes or modifications not expressly approved by the party responsible for
compliance
could void the user's authority to operate the equipment.
This device complies with Part 15 of the FCC Rules. Operation is subject to the
following
Front Side
Light Value Batter
y
Signal icon
Tem
p
erature Humidity
Indicator
Time Date

NAS‐CW01W6
深圳市丽欧电子有限公司
Version1.0.3
two conditions:
(1) this device may not cause harmful interference, and
(2) this device must accept any interference received, including interference that may
cause undesired operation.
The Water Leakage Detector is a Z‐Wave™ enabled device and is fully compatible
with any Z‐Wave™ enabled network. Z‐Wave™ enabled devices displaying the
Z‐Wave™ logo can also be used with it regardless of the manufacturer, and ours
canalsobeusedinothermanufacturer’sZ‐Wave™enablenetworks.
This product can be included and operated in any Z‐Wave™ network with other
Z‐Wave™ certified devices from other manufacturers and/or other applications.
All non‐battery operated nodes within the network will act as repeaters
regardless of vendor to increase reliability of the network.
Specification
Device:WiFi smart clock
Power:AA LR6 1.5V * 2PCS
Storage Temp:0℃ ~ 50℃ (32°F~122°F)
Storage Humidity:0% ~ 80%RH(Non condensation)
Working Temp: 0℃ ~ 50℃ (32°F~122°F)
Working Humidity:0—100%RH(Non condensation)
Wireless Standard:IEEE 802.11b/g/n
Wi-Fi Distance:40M
Weight:64g
Sleep Current:16.5uA
Status Indicator:1 LED
Wireless Frequency:2.4GHz
Light Intensity Range:0~9999Lux
Size:84mm x 55mm x 32mm
Bluetooth Pairing network:2.4GHz IEEE801.11b/g/n
Back side
The equipment
can be hung on
the wall
Reset button
Temperature scale switch

NAS‐CW01W6
深圳市丽欧电子有限公司
Version1.0.3
1. There are hanging holes on the back of the device, which can be
hung on the wall, cabinet or placed on the desk, windowsill, bedside
table and other places with light
2. The battery must be installed correctly in the battery slot which
is marked “+” “‐” direction
Battery State
1. 1. Power display has 4 grade
More than 100% full charge is greater than 2.900 full grid
75% medium 2.850‐2.900 two grids
50% less power 2.650‐2.850 one grid
Lower than 25% low power Lower than 2.650V space
(Low battery will have alarm and alarm push)
Indicator Status
Device Status Indicator
Internet connected LED light off
Smart Wi‐Fi Mode Blink 3 times per second (bluetooth with
network)
AP Mode Blink 2 times per second (bluetooth with
network)
Buzzer
Battery compartment
(open back cover to
install battery)

NAS‐CW01W6
深圳市丽欧电子有限公司
Version1.0.3
Note: 1. Both Smart Wi-Fi mode and AP compatible mode have Bluetooth mode.
2.If the device does not enter the pairing mode after the first power-on, then
press the reset button for 6 seconds
3. When the device enters to be configured or switches to be configured mode,a
prompt tone will be played
Features
1. If the device is successfully connected to the network, the indicator switches from blinking at
short intervals to off.
2.Hold down the reset button for more than 6 seconds to disconnect the network and enter the
network configuration state.
3.When the device is powered on for the first time, the device does not enter the pairing state
automatically.
4.Press the temperature scale switch button to wake up the device. Then the temperature scale
switch can be set successfully and report to the APP.
5.Support Bluetooth pairing , open bluetooth and search device automatically.
6.Light value ±20Lux will automatically report data.
7.Light display up to 9999Lux.
8.Temperature and humidity have sensitivity parameters settings, and the data will be reported
when the set parameter value is reached.
9.The default time is used when the smart clock is disconnected from the network. After the
smart clock is connected to the network, the time can be synchronized.
10.When the device alarm and alarm bell ring, press the reset button and the temperature scale
button to stop the alarm.
11.Set a maximum of five alarm clocks.
12.For the first time, the device will automatically calibrate the time, and the calibration switch
must be turned on.
13.When the device is sleeping, you can set the temperature scale, temperature and humidity
sensitivity, buzzer switch, and network time adjustment switch in cache. When the device reports
data next time, the data will be reported together with the cache Settings.
14.Humidity sensitivity 0.3℃‐‐ 2.0℃, humidity sensitivity 5%‐10%.
15.Before adjusting parameters and buzzers, ensure that the device is connected the
network.
16.After the device is connected to the network, the signal icon on the LCD isdisplayed
online.
17.After the device is disconnected from the network, the signal icon on theLCDshowsthatthe
device is offline。
18.The reporting range of illumination value

NAS‐CW01W6
深圳市丽欧电子有限公司
Version1.0.3
Download APP
1.Android:Download“Smart Life”APP from Google Play Store
2.Ios:Download “Smart Life”APP from Apple Store
1. Start the APP, register and log in
No. Illumination
Rang
(
Lux
)
Conditions for the
illumination range
variation
(
Lux
)
Illumination variation description
10—99Lux ≥±10Lux
1. The lighting value varies in
different intervals. The lighting
value will change only when the
changing conditions of the
corresponding interval are met, and
the APP will synchronize the lighting
value.
2. To determine which range the
light value is in, just look at the light
value displayed on the device.
2100—500Lux ≥±30Lux
3500—1000Lux ≥±50Lux
41000—2000Lux ≥±100Lux
52000—9999Lux ≥±200 Lux

NAS‐CW01W6
深圳市丽欧电子有限公司
Version1.0.3
Add Equipment
The device is powered on in Smart wifi mode by default (the indicator blinks at short
intervals). If the indicator is off, hold down the reset button for 6 secondsand
select the mode corresponding to the indicator to add a device
1.Select a device type to add
Note: All Wi-Fi products can be added with any Wi-Fi option. The device only supports
2.4GHz Wi-Fi signal. This manual uses the socket option
(1)Smart config mode:Press the reset button to switch device status until the
device changes to Smart Config mode, and then add (please follow the instructions
of the APP).

NAS‐CW01W6
深圳市丽欧电子有限公司
Version1.0.3
(2)AP compatible mode: Press the reset button to switch device status until the
device changes to AP mode, and then add the device (please follow the instructions
of APP).

NAS‐CW01W6
深圳市丽欧电子有限公司
Version1.0.3
(3)Bluetooth Add: Enable bluetooth to add WiFi temperature and humidity in Bluetooth
mode (you can add WiFi temperature and humidity in Bluetooth mode when Smart Config
mode and AP mode are to be configured).
1.Bluetooth add method one
2.Bluetooth add method one(Wifi temperature and humidity will be automatically searched by
Bluetooth and added)

NAS‐CW01W6
深圳市丽欧电子有限公司
Version1.0.3
Main function, working state and record settings
1.APP Main Interface
Device settings
Environment
Temperature
Environment
Humidit
y
Ambient
illumination
value
Warm
Prompt
Alarm clock(Tap
to enter the
alarm screen
)

NAS‐CW01W6
深圳市丽欧电子有限公司
Version1.0.3
二. Temperature, humidity and luminance value data curve (temperature, humidity and
luminance value data can be queried on the date of use)
三.APP Record;You can view historical alarm records of added devices in the message
center.
Smart
Temperature and
humidity alarm records
Temperature,
humidity,
brightness value
data curve
Settings

NAS‐CW01W6
深圳市丽欧电子有限公司
Version1.0.3
三.四.Smart Scene
五. Setting (temperature scale switch, temperature and humidity alarm setting, buzzer switch,
temperature and humidit
y
upper and lower
limits setting,alarm cloc
k
settings)
④
②
③
①

NAS‐CW01W6
深圳市丽欧电子有限公司
Version1.0.3
①Display the current power status of the battery;(25% will be low battery alarm);
②Temperature scale switch: Switch between degrees Celsius and Fahrenheit:
(Before setting, press the reset button to wake up the device);
③Temperature and humidity alarm: display temperature and humidity alarm 6 state; (high
temperature alarm, low temperature alarm, high humidity alarm, low humidity alarm,
temperature alarm remove, humidity alarm remove)
⑤
⑥
⑦
⑧
⑨

NAS‐CW01W6
深圳市丽欧电子有限公司
Version1.0.3
④Temperature and humidity sensitive parameters:data will be reported only when the
temperature and humidity value is reached.(Before setting, press the reset button to wake up
the device)
⑤Buzzer switch: can be set to open and close;(Before setting, press the reset button to wake
up the device)
⑥Network calibration: When network calibration is enabled, the time will becalibrated
each time. When network calibration is closed, the time will not be calibrated (press the reset
button to wake up the device before setting).
⑦Alarm clock: Set the alarm clock for different time. The alarm clock rings for one minute. A
maximumoffivealarmclockscanbeset. Presstheresetbuttonorthetemperature scale
button to pause the alarm (press the reset button to wake up the device before setting the
alarm).

NAS‐CW01W6
深圳市丽欧电子有限公司
Version1.0.3
⑧Upper and lower limits of temperature and humidity (minimum temperature ‐10 ℃,
maximum humidity 60℃, minimum humidity 0%, maximum humidity 100%)
⑨Alarm management: temperature and humidity alarm push switch, low electric alarm
push switch (press reset button to wake up the device before setting);
Other Functions
1.Shared Device

NAS‐CW01W6
深圳市丽欧电子有限公司
Version1.0.3
2.Push Management
APP all push; If push is disabled, all devices in the APP will not receive push,
but message records will not be affected.
1. 3.Clear records; Delete the device through the APP and add the device
again to clear the historical record

NAS‐CW01W6
深圳市丽欧电子有限公司
Version1.0.3
Make Your Home Smarter
Table of contents