NetPing mini-UPS User manual

1. [Docs] NetPing mini-UPS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
1.1 [ENG] Netping mini-UPS, User guide . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
1.1.1 [mini-UPS] Copyright and Disclaimer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
1.1.2 [mini-UPS] Installation and Connection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
1.1.3 [mini-UPS] Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
1.1.4 [mini-UPS] Operating and Storage Conditions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
1.1.5 [mini-UPS] Review of a Mini-UPS Device . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
1.1.6 [mini-UPS] Shipping Kit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
1.1.7 [mini-UPS] Sockets and Indication Elements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
1.1.8 [mini-UPS] Warranty . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12

Copyright © NetPing east Co., Ltd E-mail: Phone:+886-2-23121582[email protected]
[Docs] NetPing mini-UPS

Copyright © NetPing east Co., Ltd E-mail: Phone:+886-2-23121582[email protected]
[ENG] Netping mini-UPS, User guide

Copyright © NetPing east Co., Ltd E-mail: Phone:+886-2-23121582[email protected]
[mini-UPS] Copyright and Disclaimer
The information, contained in this document, can be changed by a manufacturer without a prior notice.Although every effort was made to make the
information in this document accurate and without errors, a manufacturer is not liable for their possible presence and for the consequences that may
result from the errors herein. A manufacturer is not liable if supplied equipment, software and this user guide does not correspond to expectations of a
user and his/her opinion about where and how to use all the above.All copyrights on supplied devices, described in this User Guide, as well as firmware
and software of devices and this User Guide belong to NetPing global Ltd. Сopying, replication and translation of this user guide to other
languagesare not allowed without a prior written permission of a rightholder. Copying, replication, changing, disassembling of provided software are
For the part of software that is provided in source codes, there is anot allowed without a prior written permission of a rightholder.
separate license agreement, which defines an order of its use and modification. Other trademarks used in this description belong to corresponding
rightholders.
Developer and manufacturer:
NetPing global Ltd

Copyright © NetPing east Co., Ltd E-mail: Phone:+886-2-23121582[email protected]
[mini-UPS] Installation and Connection
NetPing mini-UPScanbeinstalledonahorizontaloraverticalsurface. A body of a device has holes for its mounting.
When mounting a device, there is a need to take into account the next restrictions:
Donotpoweradevicefromtwodifferentpowersupplyunitssimultaneouslyusinga socket DJK02 and terminals +DC/GND;
Avoid direct sunlight on a device;
Do not install a device near heat sources;
Donotconnectany equipment, whichcancauseoverload, toadevice’soutputs;
Do not open a body of a device;
Beforeatransportationoralong-termstorage, setaswitchBAT into theOFF position;
Keep a switch 5V – 12V in a5V position, if you do not plan to use a terminal 12V. This will increase a battery life.
Important!When switching to theOFF position, a device goes to a power supply standby mode. A device goes out of this mode only
after connecting a power supply. Switching to the ON position does not lead a device out of a standby mode. In a standby mode a
voltage is not fed to UPS outputs.

Copyright © NetPing east Co., Ltd E-mail: Phone:+886-2-23121582[email protected]
[mini-UPS] Introduction
This user guide will help to become familiar with the peculiarities of a device operation as well as get an idea about its functionalityNetPing mini-UPS
and technical specifications, and prepare a device for operation.
A User Guide is designed for network administrators and users, who set up or operate a device. To work with a device properly, a user must have an
idea about the principles of building and functioning of local networks as well as possess the next knowledge and skills:
Basic knowledge in the area of local and global networks;
Basicknowledgeintheareaofarchitectureandprinciples of work of TCP/IP networks;
Basic knowledge in the area of architecture and principles of work of Ethernet networks.

Copyright © NetPing east Co., Ltd E-mail: Phone:+886-2-23121582[email protected]
[mini-UPS] Operating and Storage Conditions
A device is designed for continuous round the clock operation indoors. In operating conditions of use, a device is resistant to an environment with
temperature in a range of 0°С - +40°С (32 – 104 degrees Fahrenheit) and relative humidity in a range of 5% - 95 % at 25°С (77 degrees Fahrenheit)
without moisture condensation. A device should be protected from direct moisture and direct sun light.
A construction of a device provides a reliable uninterrupted work during a long period of time without maintenance.Highly developed functionality of
remote setting and configuration of a device allows changing any parameters remotely and centrally for the most of the devices.
Devices should be stored in a temperature range between - 40°С and +70°С.
In rooms for keeping a device, a content of dust, acid and alkali gases, aggressive gases and other harmful impurities causing corrosion, should not
exceed a content of corrosion-active agents for atmosphere of type 1.
Important! A device must be connected to a power supply socket with a grounding contact or a hole, where a contact, located at an outlet
and connected to a ground wire, is inserted. Grounding must be performed according to the State Standard Р 50571.21-2000. An infraction
of this rule is aviolation of a device operation conditions and may be dangerous to human lives as well as damage other devices!

Copyright © NetPing east Co., Ltd E-mail: Phone:+886-2-23121582[email protected]
[mini-UPS] Review of a Mini-UPS Device
Appearance of a device is shown on a picture:
Front panel of a device:
Back panel:

Copyright © NetPing east Co., Ltd E-mail: Phone:+886-2-23121582[email protected]
Characteristics of a Device Value
Voltage 12 V ... 48 V DC
Battery life of the deviceUniPing v3 2 hours
Battery life of the deviceUniPing server solution v3/SMS 4,5 hours
Weight 250 g
Shipping kit a device, an adapter cord
Power plug type DJK02 2.1 mm and a terminal
Temperature range 0 C ... 40 C° °
Dimensions of a device 75 x 95 x 40

Copyright © NetPing east Co., Ltd E-mail: Phone:+886-2-23121582[email protected]
[mini-UPS] Shipping Kit
Into shipping kit are included:
A deviceNetPing mini-UPS;
Mating terminals– 4 pcs.;
Power cable.

Copyright © NetPing east Co., Ltd E-mail: Phone:+886-2-23121582[email protected]
[mini-UPS] Sockets and Indication Elements
StateTerminal Block
A state terminal block is a set of logic outputs (IO lines), which are used for a device status signalling.
A terminal 1 is an output “normal”. Its logic level “1” (no less than 2.4V) indicates an availability of an input voltage, a battery is charging. A level “0”
(no more than 0.4 V) indicates a lack of an input voltage, a battery is discharging.
A terminal is an output “critical level”. “1” is a normal battery level, “0” - a battery is critically discharged, it is issued 3-6 minutes before a device
shutdown.
Aterminal 3 – GND
DC/BAT LED
DC/BAT LED. A greenlightmeanshavingavoltageonaninput. Aredonemeansthereisnovoltageoninput, a battery is discharging.
OUTPUT VOLTAGE Block
An OUTPUT VOLTAGE block, which isa UPS output, consists of 5V/GND, 12V/GND terminals and a 5V – 12V switch.
A switch 5V – 12V is used for turning on/offa 5V -> 12V transformation.
A terminal 5V is an output of UPS+5V. Thereisalwaysavoltageonthisterminalduringadeviceoperationregardless a position of a 5V – 12V switch.
A terminal 12V is an output of UPS+12V. There is a voltage on this terminal only when a 5V-12V switch is at a 12V position.
Important!Keep a switch 5V – 12V in a position 5V, if you do not plan to use a terminal 12V. This will increase a battery life time.
DC INPUT Block
A DC INPUT block (picture 8), which is an UPS input, consists of a socket DJK02 for 2.1 mm dowel and +DC/GND terminals.
ADJK02 socketfora2.1 mm dowelisusedtopower amini-UPS device with the help of a power supply unit, for example, Power adaptor NetPing.
+DC/GND terminalsareusedtopower a mini-UPS device with the help of other Netping devices, for example, Uniping v3, Uniping Server Solution
v3/SMS. For these purposes, a 12V relay, built into a body of devices, is used.
Important!It is prohibited to power a mini-UPS device simultaneously from two different power supply units through the socket
DJK02 and the terminals +DC/GND.
BATSwitch
A BAT switch is used to unplug a battery before a transportation or a long-term storage of a device. A device supplies a voltage to outputs, when there
is an external power supply, even if a switch is in an OFF position.
Important!Switching to the OFF position puts a device into a standby power mode, when there is no external power supply. A device
exits this mode when a power is supplied. Switching to the ON position will not put a device out of a standby power mode. In a
standby mode a voltage is not supplied to UPS outputs.

Copyright © NetPing east Co., Ltd E-mail: Phone:+886-2-23121582[email protected]
[mini-UPS] Warranty
The manufacturer guarantees normal operating of the product within 24 months from the date specified on the warranty sticker if a buyer follows
operating and storage conditions. Manufacturer warranty applies only to failure of a device, which occurred because of defects in manufacturing
process of products and components used. If during a warranty period, the manufacturer receives a notice of such defects, it will repair or exchange a
product (by its own discretion). If the manufacturer is unable to repair or replace a flawed item during a period of time determined by the current
legislation, the manufacturer according to a customer’s wish can return the amount paid for the product at the time of purchase. The manufacturer
provides a limited warranty on firmware and device configuration software. In case of detecting any errors in software, which became known to the
manufacturer on its own or from a customer, the manufacturer will fix these errors within a reasonable time and provide an update for the
customer.Only the errors that block normal use of the device at conditions and for performing functions, described in this User Guide, are subject to
mandatory fix.This warranty does not apply to cases, when defects appear because of: a misuse of a device, any modifications of a device without a
written permission of the manufacturer, opening up a device, except cases, foreseen by this description, repairing by unauthorized personnel, using or
storing a device out of the range of allowable temperature and humidity, pressure, a software modification, and the reasons, listed below:
A device failed because of the problems in a public electric network, plugging a device into power supply networks with invalid parameters,
absence of grounding, etc. (power fluctuations and surges, overloading, etc.);
A device failed because of a liquid inside;
A device failed as a result of extreme temperatures;
A device failed because of mechanical damage;
A device failed because of connecting a power supply unit with invalid output voltage or a defective power supply unit;
There are foreign objects, insects, etc inside the enclosure;
During operation, a voltage bigger than an allowable voltage range by the Ethernet standard has been supplied to the ports of a device.