Neurtek ATX User manual

ATX Automatic Applicator
Instruction Manual
NEURTEK S.A.
your supplier of instruments for quality control
Maintenance and Calibration Services
www.neurtek.com
Tel.: 943 820 790
Rev. 01 / Page 1 of 12
NEURTEK S.A. RESERVES THE RIGHT TO CHANGE WITHOUT PRIOR NOTICE.
Read this manual carefully before using the equipment.

ATX Automatic Applicator
Instruction Manual
NEURTEK S.A.
your supplier of instruments for quality control
Maintenance and Calibration Services
www.neurtek.com
Tel.: 943 820 790
Rev. 01 / Page 2 of 12
NEURTEK S.A. RESERVES THE RIGHT TO CHANGE WITHOUT PRIOR NOTICE.
1 Description of the product
S
The device must be connected to 220 V with the provided power supply.

ATX Automatic Applicator
Instruction Manual
NEURTEK S.A.
your supplier of instruments for quality control
Maintenance and Calibration Services
www.neurtek.com
Tel.: 943 820 790
Rev. 01 / Page 3 of 12
NEURTEK S.A. RESERVES THE RIGHT TO CHANGE WITHOUT PRIOR NOTICE.
2 Operation
The device has a button at the back on the right for switching it on/off.
When turning on the device, after the initial screen, you will see the main screen which displays the
current test parameters.
Bear in mind that when switching off the device, the last test parameters used are kept.
Current parameters:
Travel length: 120 mm
Speed: 150 mm/s
To start press

ATX Automatic Applicator
Instruction Manual
NEURTEK S.A.
your supplier of instruments for quality control
Maintenance and Calibration Services
www.neurtek.com
Tel.: 943 820 790
Rev. 01 / Page 4 of 12
NEURTEK S.A. RESERVES THE RIGHT TO CHANGE WITHOUT PRIOR NOTICE.
Attaching the contrast card:
Centre the contrast card on the base, lift the lever of the fastening system and insert the contrast card
as far as it will go.
Once it is properly positioned, release the lever so that the contrast card is secured.

ATX Automatic Applicator
Instruction Manual
NEURTEK S.A.
your supplier of instruments for quality control
Maintenance and Calibration Services
www.neurtek.com
Tel.: 943 820 790
Rev. 01 / Page 5 of 12
NEURTEK S.A. RESERVES THE RIGHT TO CHANGE WITHOUT PRIOR NOTICE.
For use with quadrangular applicator:
Position the slide bar, sliding it over the pins until it is secured.

ATX Automatic Applicator
Instruction Manual
NEURTEK S.A.
your supplier of instruments for quality control
Maintenance and Calibration Services
www.neurtek.com
Tel.: 943 820 790
Rev. 01 / Page 6 of 12
NEURTEK S.A. RESERVES THE RIGHT TO CHANGE WITHOUT PRIOR NOTICE.
Place the quadrangular applicator in the centre, touching the slide bar

ATX Automatic Applicator
Instruction Manual
NEURTEK S.A.
your supplier of instruments for quality control
Maintenance and Calibration Services
www.neurtek.com
Tel.: 943 820 790
Rev. 01 / Page 7 of 12
NEURTEK S.A. RESERVES THE RIGHT TO CHANGE WITHOUT PRIOR NOTICE.
Performing the test:
If the current parameters are the desired ones:
Press the key
For safety, the device will ask if everything is OK.
Press the key again and the test will start:
Current parameters:
Travel length: 120 mm
Speed: 150 mm/s
To start press
IS EVERYTHING CORRECTLY
POSITIONED?
To start press
TEST IN ACTION
Current parameters:
Travel length: 120 mm
Speed: 150 mm/s
If you want to interrupt press

ATX Automatic Applicator
Instruction Manual
NEURTEK S.A.
your supplier of instruments for quality control
Maintenance and Calibration Services
www.neurtek.com
Tel.: 943 820 790
Rev. 01 / Page 8 of 12
NEURTEK S.A. RESERVES THE RIGHT TO CHANGE WITHOUT PRIOR NOTICE.
When the travel length has been reached the device remains in standby:
To return to the start position press the key. The device stops at the start position,
ready for another test:
TEST COMPLETED
To start again press
Current parameters:
Travel length: 120 mm
Speed: 150 mm/s
To start press

ATX Automatic Applicator
Instruction Manual
NEURTEK S.A.
your supplier of instruments for quality control
Maintenance and Calibration Services
www.neurtek.com
Tel.: 943 820 790
Rev. 01 / Page 9 of 12
NEURTEK S.A. RESERVES THE RIGHT TO CHANGE WITHOUT PRIOR NOTICE.
During the test:
If you need to interrupt the test, you can press the key and the device will stop at its current
position.
If you want to stop the test, press the key and the device will return to the starting
point.
If you want to continue the test from the point where it has stopped, press the key
and the test will continue using the programmed speed and length.
TEST INTERRUPTED
To continue press
To stop and return to
the start press

ATX Automatic Applicator
Instruction Manual
NEURTEK S.A.
your supplier of instruments for quality control
Maintenance and Calibration Services
www.neurtek.com
Tel.: 943 820 790
Rev. 01 / Page 10 of 12
NEURTEK S.A. RESERVES THE RIGHT TO CHANGE WITHOUT PRIOR NOTICE.
Change of test parameters:
To change the test parameters, the device must be in the standby position and the runner must be in
the initial working position.
To enter the submenu for changing the parameters hold down the key for about 3 seconds
and the following screen will appear:
Which provides a quick indication on how to change the parameters.
Press to start changing the parameters. The following screen will appear:
The value to be changed will flash. To switch between the travel length and speed values press the
keys
To increase or decrease the value press
Once you have adjusted the parameters press to return to the main screen and the test can
be started.
Change of test parameters
Press -/+ to decrease/increase
the value
Press the arrows to change the
parameter
Press START to begin making the changes
Change of test parameters
Travel length: 120 mm
Speed: 150 mm/s
To confirm press

ATX Automatic Applicator
Instruction Manual
NEURTEK S.A.
your supplier of instruments for quality control
Maintenance and Calibration Services
www.neurtek.com
Tel.: 943 820 790
Rev. 01 / Page 11 of 12
NEURTEK S.A. RESERVES THE RIGHT TO CHANGE WITHOUT PRIOR NOTICE.
Changing the language:
To change the language, the device must be in the standby position and the runner must be in the
initial working position.
To enter the submenu for changing the parameters hold down the key for about 3
seconds and the following screen will appear:
The current language will flash. To switch to the desired language press the
keys and once selected, confirm by pressing to return to the main screen.
Spanish
French
German
English
Select using up/down arrow
Confirm with START/STOP
LANGUAGE

ATX Automatic Applicator
Instruction Manual
NEURTEK S.A.
your supplier of instruments for quality control
Maintenance and Calibration Services
www.neurtek.com
Tel.: 943 820 790
Rev. 01 / Page 12 of 12
NEURTEK S.A. RESERVES THE RIGHT TO CHANGE WITHOUT PRIOR NOTICE.
If the runner is not in the initial position when the device is turned on, the following screen appears:
The device must be position itself correctly, so make sure that the workspace is free of obstacles and
press , the runner will go back to the initial position, the main screen will appear and you can
start the test
POSITION CONTROL
ATTENTION:
The device must position itself
correctly
Clear the space and press
Table of contents
Other Neurtek Test Equipment manuals