Newco Bistro 1 Installation guide

BISTRO 1
By NEWCO Enterprises
Installation
And
Programming Guide

Bistro 1
NEWCO Enterprises Phone: 1.800.325.7867 Fax: 1.636.925.0029 12.09.10
- 2 -
Section 1 – Installation Instructions
Section 2 – Set-Up Programming Instructions
Section 3 – Service Level Programming Instructions
Section 1
Installation Instructions:
Place Machine on a Level Countertop Surface
Connect ¼ Inch Flare water Supply to the Water Inlet
located on lower Left Rear of the Machine.
(
(N
NE
EW
WC
CO
O
r
re
ec
co
om
mm
me
en
nd
ds
s
c
co
op
pp
pe
er
r
t
tu
ub
bi
in
ng
g
f
fo
or
r
u
us
se
e
a
as
s
w
wa
at
te
er
r
s
su
up
pp
pl
ly
y
t
to
o
a
al
ll
l
o
of
f
o
ou
ur
r
b
br
re
ew
wi
in
ng
g
e
eq
qu
ui
ip
pm
me
en
nt
t)
)
Turn water Supply On
Plug or wire brewer to the appropriate voltage circuit as
indicated on the serial tag.
Locate power switch on the lower left rear of the machine
and turn machine power on.
Machine will begin to fill.
If machine has not filled to probe level within 2 minutes it will enter an error
mode. Error code E-4 will appear on the display screen. To reset the error
and resume filling turn power switch off and then on.
When water in tank reaches probe level, heating cycle will
begin.
BY DEFAULT THE MACHINE IS SET FOR SINGLE,
DOUBLE, AND TRIPLE SHOT DISPENSES. TO CHANGE
THESE SETTINGS, SEE SET-UP PROGRAMMING
INSTRUCTIONS ON THE NEXT PAGE

Bistro 1
NEWCO Enterprises Phone: 1.800.325.7867 Fax: 1.636.925.0029 12.09.10
- 3 -
Section 2
Set-Up Programming Instructions:
Open machine cabinet door and locate the 3-switch control
panel w/lighted display screen. Three dashed lines will
appear on the display screen, as shown in figure 1.
Step 1. Enter a Programming Mode
Press and hold the center switch labeled “Enter”. Continue to
hold in the switch and the temperature will appear, (Release
the switch when temp. appears on the display.) as shown in
figure 2A.
Fig. 1
Fig. 2A
Fig. 2 - - - 185

Bistro 1
NEWCO Enterprises Phone: 1.800.325.7867 Fax: 1.636.925.0029 12.09.10
- 4 -
Step 2. Adjust Temperature
The machine features an adjustable temperature range of
170-190F. Use the +or – switch to scroll to the desired
temperature setting, as shown in figure 3.
Press the “Enter” switch to save and proceed to the next
programming option. Either the word “YES” or the word “NO”
will appear on the display screen. Proceed to Step 3.
Step 3. Beeper Selection ON or OFF
On or will appear on the display screen, as shown in figure
3A. Toggle the Beeper ON or OFF with the + or – switch, Fig
4. (Beeper signals when drink is ready, it can be turned on or
off) Press the SETTINGS button and screen will display SEL
as in Fig 5. Proceed to Step 4.
Fig. 3 Fig. 3A
Fig. 5
on
SEL
185
off
Fig. 4

Bistro 1
NEWCO Enterprises Phone: 1.800.325.7867 Fax: 1.636.925.0029 12.09.10
- 5 -
Step 4. Program Selector Switches
This machine features a 6-selector switch control panel.
These 6 switches can be programmed to deliver different
strength drinks or different sized drinks-See Programming
directions on page 6.
Changing the Gram Throw (Auger Speed):
To change the AUGER SPEED for the Augers using the
selector switch (Figure 9)
Gram Throw Speed (1-25)
Approx.
Gram Throw
Auger Speed
Setting
9 g/oz 11
8 g/oz 10
7 g /oz 9
6 g /oz 8
5 g /oz 7
4 g /oz 6
3 g /oz 5
THIS TABLE IS FOR REFERENCE, SET FINAL AUGER SPEED BY TASTE

Bistro 1
NEWCO Enterprises Phone: 1.800.325.7867 Fax: 1.636.925.0029 12.09.10
- 6 -
To Program the selector switch:
1. When the screen shows “SEL”, on the selector switch
control panel, press the switch labeled Single Shot. The
display will change to identify the switch that you have
chosen as in Fig 6.
2. 2. Press Enter. The number “1” and the current auger
speed will appear in the display, as shown in figure 7.
3. Using the +or –button to scroll, set Auger speed for
the desired speed.
Fig 9
Fig 7
BUTTON 6
b:06
1:5
BUTTON 5
BUTTON 3
Fig 6
BUTTON 4
BUTTON 2
BUTTON 1
NORMALLY NOT
USED

Bistro 1
NEWCO Enterprises Phone: 1.800.325.7867 Fax: 1.636.925.0029 12.09.10
- 7 -
4. Press “Settings” to save and proceed with the set-up
program. A time value (min: sec) will appear in the
display. If the switch that you are programming has
been set in a portion control mode, the value will
represent the current dispense time for the switch in
seconds(Fig 8). If the switch is in a continuous flow
(push and hold) mode, the time value will be 0:00
Shown in figure 9.
5. Press and release the “settings button to store switch
settings. The display will return to “SEL”. To program
another switch, repeat the instructions for programming
the selector switch, above. Pressing the settings button
after all the switches have been programmed will return
normal operating mode and the display will change to “-
- -“ as in figure 1, above.
Rinsing Instructions: Rinse the mixing chamber by pressing and
holding the “Rinse “ button until the bowl is clean and the water
runs clear.
Fig 8
08.1
Fig 9
00.0

Bistro 1
NEWCO Enterprises Phone: 1.800.325.7867 Fax: 1.636.925.0029 12.09.10
- 8 -
Section 3
Service section
Error Messages:
Error
Number Description Cause What to Check
tHU/ tHL Thermistor warning –
immediately upon detection the
machine will beep twice and
show the warning message for
a minute as well as turn on the
right most upper dot on the
display. This dot will stay on to
signify there is a thermistor out.
Also upon power up the
machine will beep twice and
show the warning message for
a short period of time and turn
on the high dot if the warning
conditions are present
Resistance extremely high from
upper or lower thermistor will
cause or the resistance extremely
low from upper or lower
thermistor will cause a tHU or tHL
warning for the thermistor that
sees the condition and causes
the control board to switch from
watching the lower to the upper
thermistor. If both the upper and
lower resisters fail then we flag a
thermistor ErC error
This warns you that 1
thermistor has failed. Nothing
is required at this time as the
upper thermistor has taken
over but ordering a
replacement thermistor is
advisable
Er3 Heater Run Error Water did not heat within timeout
period. Timeout period is 120
seconds which is reloaded
whenever the heater is off or the
fill valve is on
Check element for short and
proper resistance. Check
heater relay. Check for
tripped button on Hi-Limit
Thermostat.
Er4 Tank Fill Error Water did not reach probe in
timeout period of 2 minutes for
initial fill and 20 seconds minute
during normal operation. The 2
minute fill time is reloaded if no
key is pressed within 24 hours
Check valve function and flow
rate. Replace valve or
increase flow rate. Check
probes for excess scale.
Er5 Comm Error Serial communication error
to/from non-volatile memory
(EEPROM).
Hold down the enter key to
enter Machine Set up mode
pressing the enter key to
cycle through all options then
exit mode. This resets all the
defaults. If the error still
occurs then replace main
board.
Er7 Open Motor Circuit - The motor
errors (Er7 and Er8) do not
cause a system error and will
not shut down the machine.
Immediately upon detection the
machine will beep twice and
show the error message. Every
time the key is pressed to
activate a auger motor it clears
the error and allow another
attempt to be made. If this error
occurs the dump valve still will
release water.
Open motor circuit, Auger Retry Auger if the error still
occurs then check
harness/motor continuity.
Replace if defective.
Note: Turn machine Off then back On to Clear Error Messages

Bistro 1
NEWCO Enterprises Phone: 1.800.325.7867 Fax: 1.636.925.0029 12.09.10
- 9 -
Error Messages Cont’d:
Er8 Bad (Open) Motor Driver - The
motor errors (Er7 and Er8) do
not cause a system error and
will not shut down the machine.
Immediately upon detection the
machine will beep twice and
show the error message. Every
time the key is pressed to
activate the auger motor it
clears the error and allows
another attempt to be made. If
this error occurs the dump
valve still will release water.
Bad/open motor driver. Product
Auger Retry auger if the error still
occurs then replace main
board.
Erb Dry Firing Tank – the tank is
empty but the heater is on. The control board has either seen
a rise in temperature of 1 degree
a second, for 5 seconds or has
seen the temperature rise to
215°F or above
The unit has been in the
intent to brew timeout for an
extended period of time,
allowing the tank to evaporate
to the point where there is
little water in the tank
ErC Thermistor Error Resistance extremely high from
upper or lower thermistor will
cause or the resistance extremely
low from upper or lower
thermistor will cause a tHU or tHL
warning for the thermistor that
sees the condition and causes
the control board to switch from
watching the lower to the upper
thermistor. If both the upper and
lower resisters fail then we flag a
thermistor error
Check/replace thermistor.
Note: Turn machine Off then back On to Clear Error Messages

Bistro 1
NEWCO Enterprises Phone: 1.800.325.7867 Fax: 1.636.925.0029 12.09.10
- 10 -
Dimensions & Electrical Specifications:
**Electrical Specs**
Bistro 1 Machine
120V 1600W
15 Amps
IDQ HOT CHOCOLATE DISPENSER
18.07
21.34 7.36

Bistro 1
NEWCO Enterprises Phone: 1.800.325.7867 Fax: 1.636.925.0029 12.09.10
- 11 -
NEWCO PRODUCT WARRANTY
NEWCO warrants equipment manufactured by it for 1-year parts and labor.
These warranty periods run from the date of purchase. NEWCO warrants that the
equipment manufactured by it will be commercially free of defects in material and
workmanship existing at the time of manufacture and appearing within the
applicable warranty period. This warranty does not apply to any equipment,
component, or part that was not manufactured by NEWCO or that, in NEWCO’S
judgment, has been affected by misuse, neglect, alteration, improper installation
or operation, improper maintenance or repair, damage or casualty. This warranty
is conditioned on the Buyer: 1) Giving NEWCO prompt notice of any claim to be
made under this warranty by telephone at (800) 556-3926 or by writing to PO
Box 852, Saint Charles, MO 63302 2) If requested by NEWCO, shipping the
defective equipment prepaid to an authorized NEWCO service location 3)
Receiving prior authorization, from NEWCO, that the defective equipment is
under warranty.
THE FOREGOING WARRANTY IS EXCLUSIVE AND IS IN LIEU OF ANY
OTHER WARRANTY, WRITTEN OR ORAL, EXPRESS OR IMPLIED,
INCLUDING, BUT NOT LIMITED TO, ANY IMPLIED WARRANTY OF EITHER
MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. The
agents, dealers, or employees of NEWCO are not authorized to make
modifications to this warranty or to make additional warranties that are binding on
NEWCO. Accordingly, statements by such individuals, whether oral or written, do
not constitute warranties and should not be relied upon.
If NEWCO determines in its sole discretion that the equipment does not conform
to the warranty, NEWCO, at its exclusive option while the equipment is under
warranty, shall either: 1) Provide at no charge replacement parts and/or labor
(during the applicable parts and labor warranty periods specified above) to repair
the defective components, provided that this repair is done by a NEWCO
Authorized Service Representative or 2) Shall replace the equipment or refund
the purchase price for the equipment.
THE BUYER’S REMEDY AGAINST NEWCO FOR BREACH OF ANY
OBLIGATION ARISING OUT OF THE SALE OF THIS EQUIPMENT,
WHETHER DERIVED FROM WARRANTY OR OTHERWISE, SHALL BE
LIMITED, AT NEWCO’S SOLE OPTION AS SPECIFIED HEREIN, TO REPAIR,
REPLACEMENT OR REFUND.
In no event shall NEWCO be liable for any other damage or loss, including, but not
limited to, lost profits, lost sales, loss of use of equipment, claim’s of BUYER’S
customers, cost of capital, cost of downtime, cost of substitute equipment, facilities or
services, or any other special, incidental, or consequential damages.

Bistro 1
NEWCO Enterprises Phone: 1.800.325.7867 Fax: 1.636.925.0029 12.09.10
- 12 -
Wiring diagram
Table of contents
Other Newco Coffee Maker manuals

Newco
Newco B-10-T Instruction Manual

Newco
Newco GXF-8D User manual

Newco
Newco FKP-3 User manual

Newco
Newco ACE-S Setup guide

Newco
Newco IA AP User manual

Newco
Newco OCS-8 User manual

Newco
Newco FC Series Installation instructions

Newco
Newco LCD-TCH Instruction Manual

Newco
Newco DUAL 20:1 Series Quick start guide

Newco
Newco Cafe Espresso 2.0 User manual

Newco
Newco Bistro Touch Instruction Manual

Newco
Newco GKDF2-30 Setup guide

Newco
Newco Moo-Cafe User manual

Newco
Newco KMA User manual

Newco
Newco AKH AP Technical manual

Newco
Newco CT-2A Instruction and safety manual

Newco
Newco NKLDAF User manual

Newco
Newco WonderBrew User manual

Newco
Newco Smart Cup User manual

Newco
Newco KP-1 Instruction and safety manual