  9. NEXTIVITY CEL-FI GO G41 User manual

NEXTIVITY CEL-FI GO G41 User manual

CEL-FI GO G41
Quick Start Guide
Included In the Box
Screws (4)
Drywall Anchors (4)�
AC Adapter
Main Unit
Donor Antenna*
Server Antenna*
Cable*
G41-JE-001
G41-JE-002
G41-JE-003
G41-NE-001
KIT#:
G41-NE-002
G41-NE-003
G41-9E-001
G41-9E-002
G41-9E-003
G41-TE-003
G41-DE-003
G41-LE-003
G41-TE-00A
G41-DE-00A
G41-LE-00A
G41-PE-003
*Included with certain kits only.
Quick Installation IMPORTANT: Your CEL-FI GO G41 is electronic equipment. The CEL-FI GO G41
must be kept indoors and in a dry, cool, well ventilated area.
11
3344
22
Dene Coverage Problem
Attach Server and Donor Antennas Plug In CEL-FI GO G41
Place Main Unit
Use your phone to nd where coverage
is needed. This is where the Server Antenna
should be installed on a wall.
Attach the cable from the Donor Antenna to the Donor
Port on Main Unit.
Must mount the server
antenna horizontally.
Place the main unit as far away from the
server antenna as the cable will allow, close
to a window where there is coverage.
Plug in the Main Unit to power with the included AC adapter.
The LED on the front will blink during set up and turn green when
the device is ready. After powering on the device, connect the
Power Cable Clamp.
Donor
Antenna
55Congure with the WAVE App
Download the WAVE App to monitor your
system status. Connect the Main Unit us-
ing category cable to your ISP modem LAN
port or external LTE modem to manage via
web interface WAVE Portal.
WAVE app smart phone connects to
the CEL-FI GO G41 via Bluetooth LE:
Frequency: 2402-2480 MHz
Power: 0 dBm
1 2
3 4
NOTE: This package comes equipped with Mounting Screws and Drywall Anchors for mounting to standard drywall.
Before installing, ensure there are no wires, other objects, or metal plates behind the drywall that may interfere with the inserts,
screws , or mounted units.
REQUIRED HARDWARE
In each marked spot, use a
3/16” drill bit to drill guide
holes for the Drywall Anchors,
and then Install the anchors.
www.nextivityinc.com/antennas
For best results, separate the Donor and Server
Antenna(s) as much as possible. Antenna
separation (isolation) can be achieved with either
physical distance or walls and oors between the
antennas.
Make sure any cables, splitters, and antennas used
in the system are properly matched. (CEL-FI GO G41
is rated for 50 Ω)
Recommended:
• > 20 dB port-to-port isolation for any splitter
Downlink power should be:
• > 0 dBm to use a two-way splitter
• > 3 dBm to use a four-way splitter
Mount the Main Unit and then attach
the Donor and Server Antennas.
Mark the four mounting
hole locations with a pencil
based on where you’ll
position the Main Unit.
Determine Cel-Fi GO G41 location.
(Refer to Installation section).
Determine mounting hole locations.
Mounting Instructions (Optional)
Antenna Options
Exernal Antenna
Splitting Server Antenna Multi-Story
Advanced Install
Review the latest authorized antennas at:
Copyright © 2023 by Nextivity, Inc., U.S. Patents pending. All rights reserved. The Nextivity and CEL-FI logos are registered trademarks of Nextivity,
Inc. All other trademarks or registered trademarks listed belong to their respective owners. Designed by Nextivity, Inc. in California.
qsg-go-g41_1-3-5-28L_eng_23-0919
band link Output
Power EIRP*
1Downlink 20 (dbm) 25.1 (dbm)
Uplink 22 (dbm) 27.1 (dbm)
3Downlink 20 (dbm) 25.1 (dbm)
Uplink 22 (dbm) 27.1 (dbm)
5Downlink 20 (dbm) 25.4 (dbm)
Uplink 20 (dbm) 25.4 (dbm)
7Downlink 20 (dbm) 25.4 (dbm)
Uplink 22 (dbm) 27.4 (dbm)
8Downlink 20 (dbm) 25.1 (dbm)
Uplink 20 (dbm) 25.1 (dbm)
20 Downlink 20 (dbm) 25.1 (dbm)
Uplink 20 (dbm) 25.1 (dbm)
28L Downlink 20 (dbm) 25.1 (dbm)
Uplink 20 (dbm) 25.1 (dbm)
28U Downlink 20 (dbm) 25.1 (dbm)
Uplink 20 (dbm) 25.1 (dbm)
40 Down link 20 (dbm) 25.4 (dbm)
Uplink 22 (dbm) 25.4 (dbm)
41 Down link 20 (dbm) 25.4 (dbm)
Uplink 22 (dbm) 25.4 (dbm)
Model Number Bands Supported
G41–JE 1, 3, 5, 7, 8, 28L, 40
G41–9E 1, 3, 7, 8, 20
G41–NE 1, 3, 5, 7, 28U, 40
G41–PE 1, 3, 5, 7, 8, 28L, 41
G41–TE 1, 3, 41
G41–DE 1, 3, 28L
G41–LE 1, 3
*Tested with donor antenna (A21-ML3-601) & server
antenna (A41-NL3-101)

This manual suits for next models

16

Other NEXTIVITY Network Hardware manuals

NEXTIVITY ROAM R41 User manual

NEXTIVITY

NEXTIVITY ROAM R41 User manual

NEXTIVITY SHIELD MegaFi User manual

NEXTIVITY

NEXTIVITY SHIELD MegaFi User manual

NEXTIVITY CEL-FI GO G51 User manual

NEXTIVITY

NEXTIVITY CEL-FI GO G51 User manual

NEXTIVITY SHIELD MegaFi User manual

NEXTIVITY

NEXTIVITY SHIELD MegaFi User manual

NEXTIVITY CEL-FI CONNECT C41 User manual

NEXTIVITY

NEXTIVITY CEL-FI CONNECT C41 User manual

Popular Network Hardware manuals by other brands

Perle IOLAN SCG Series Hardware installation guide

Perle

Perle IOLAN SCG Series Hardware installation guide

EARDATEK EWN-8720CMN1AA Getting started guide

EARDATEK

EARDATEK EWN-8720CMN1AA Getting started guide

ADTRAN Total Access SHDSL LTU Installation and maintenance practice

ADTRAN

ADTRAN Total Access SHDSL LTU Installation and maintenance practice

GAPOSA linkIT-Control4 manual

GAPOSA

GAPOSA linkIT-Control4 manual

BT NTU6 operating guide

BT

BT NTU6 operating guide

NetComm Freshtel NB9W Upgrade instructions

NetComm

NetComm Freshtel NB9W Upgrade instructions

Thinklogical SCS80 product manual

Thinklogical

Thinklogical SCS80 product manual

Creator PGMIII user manual

Creator

Creator PGMIII user manual

dallmeier IPS 2400 II Commissioning

dallmeier

dallmeier IPS 2400 II Commissioning

Extron electronics MAAP Active Modules VCM 100 MAAP Specification sheet

Extron electronics

Extron electronics MAAP Active Modules VCM 100 MAAP Specification sheet

TYANO S7126 manual

TYANO

TYANO S7126 manual

ADTRAN SFP+ quick start

ADTRAN

ADTRAN SFP+ quick start

Advantech FWA-T011 user manual

Advantech

Advantech FWA-T011 user manual

Oracle Acme Packet 4500 Hardware installation guide

Oracle

Oracle Acme Packet 4500 Hardware installation guide

Dell VxRail P670F Installation and service manual

Dell

Dell VxRail P670F Installation and service manual

Paradyne ACCULINK 336x E1 Operator's guide

Paradyne

Paradyne ACCULINK 336x E1 Operator's guide

BlueNet Video BB01 instruction manual

BlueNet Video

BlueNet Video BB01 instruction manual

Acumen AiS installation manual

Acumen

Acumen AiS installation manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.