Nexxt Solutions Professional Series User manual

ProfessionalSeries
2-post, 19-inch open rack
Steel frame with square holes
25/45
RACK UNITS
NPO-2P25UB
NPO-2P45UB

User manual
Caution: this product is heavy, at least two qualified people should perform the
assembly procedure. Care must also be taken while moving or positioning the
equipment.
Do not exceed the recommended load capacity per shelf, and the maximum weight
supported by the rack, as specified by the manufacturer's specifications. Failure to
comply will void the warranty of this product.
Safety measures must be practiced at all times during the assembly of this product.
Caution: use the recommend tools to avoid damaging the parts.
RACK TIPPING HAZARD: ensure that the rack is properly anchored to the floor
before equipment is installed.
Nexxt solutions does not warrant against damage caused by the use of any Nexxt
Solutions structures for any purposes other than those for which it was designed or
damage caused by unauthorized attachments or modifications, and is not responsible
for any damages, claims, demands, suits, actions, or causes of action of whatever kind
resulting from, arising out of or in any manner relating to any such use, attachments or
modifications.
1. Introduction
Thank you for purchasing the two-post open rack from Nexxt Solutions. Available with
25 and 45 rack spaces, these units are constructed of heavy-duty steel, allowing the
safe integration of networking equipment and additional accessories in environments or
areas that do not require a lockable rack solution. Designed for easy deployment in
high-load and high-density infrastructures, this metalwork component is ideal for
housing diverse IT equipment and other voice/data devices where space is at a
premium. Easy to install and to assemble, our open racks offer a cost -eff effective
solution for applications requiring increased flexibility, accessibility, and cable
management capabilities.
Main features
• 2-post, floor-standing open frame rack
• Supports stationary loads of up to 992lb (450kg)
• Ample ventilation and unobstructed airflow keep your equipment at room temperature
• It provides a convenient solution with easy access to your cabling, IT and
communications components
• Front and rear equipment installation for larger networking systems
• Numbered square-hole mounting positions for faster attachment of 19-inch
components
• Powder coat finish prevents damage caused by rust and other external factors
For support and to find out more about our complete line of products and solutions,
we invite you to visit us at nexxtsolutions.com.
Carefully read and follow the safety
instructions included in this manual before
assembling and using the unit.
FAILURE TD FOLLOW THESE INSTRUCTIONS CAN LEAD TD
SERIOUS INJURY, DEATH, OR DAMAGE TO YOUR EQUIPMENT.
IMPORTANT SAFETY INFORMATION
2. Preliminary steps
• Prior to installing this product, you must read all instructions thoroughly.
• Keep these instructions handy in an easily accessible location for future reference. .
• A clean, flat, level, protected floor area should be provided for rack assembly to
prevent damage to parts.
• The installers may need to have the following items and tools available to assemble
and install the rack. They are not included in the box.
1. Phillips screwdriver
2. Power drill with the following bits:
M8 hexagonal-head tip
3. M8 hex to square socket adaptor
4. Pair of gloves
5. Long nose pliers
6. Cleaning towel
7. 3mx2m mat or padded surface
1 2 3 64 5
ELECTRICAL
SHOCK
HAZARD.
DANGER All parts of the unit must be properly grounded to the frame
of the rack and connected to the Common Bonding Network
[CBN) of your facility.
1 2

3. Product overview and components
Upon opening the box, make sure to inspect and account that all the items
listed below are included.
Part ID Item Quantity Image
Vertical rail
Top support bracket
Bottom support bracket
Base stand with holes for anchoring
Base extension plate
M8x16mm hexagon bolt
2
1
1
2
2
M8 flat metal washer
Combination wrench M8 (13mm)
M10x80mm anchoring bolt
Split-lock washer (anchoring)
Flat metal washer (anchoring)
M10 nut (anchoring)
M8 cage nut
M8 plastic flange washer
M8x12mm phillips-head screw
M4 philllips self-tapping screw
Cable management hook
User manual
16
1
4
4
4
4
40
40
40
14
14
1
16
1
4
4
4
4
20
20
20
8
8
1
1616
Rack assembly components
Rack assembly hardware (continued)
Equipment mounting hardware
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
Rack assembly hardware
25U 45U
Quantity
25U 45U
Quantity
3 4

4. Assembly procedure (recommended)
Upon opening the box, inspect the contents to ensure that all the items listed above
are included:
• The illustration provides a view of all the rack
components you are about to put together.
• Open the boxes and verify that all parts, hardware
and accessories are included in the package.
• Inspect the rack components and identify each
individual part to ensure proper assembly of the unit.
M8 combination wrench (13mm)
1
Top frame subassembly
1. Align the top bracket with the holes on the left vertical rail and
secure it using the M8 bolts and washers.
Note:
If necessary, lay the subassembly down on a flat surface to attach
the top bracket.
Make sure not to fully-tighten the bolts until all fasteners have been
installed.
2. Repeat the same instruction to complete the right side.
Phase Required parts Step
Top support bracket (1)
Vertical rails (2)
M8x16mm hexagonal bolts (8)
M8 metal washers (8)
2
2
4
1
11
7
8
6
3
5 6

2
Note: In this stage, firmly tighten all the bolts to properly secure,
align and square off the unit. You can use the supplied self-tapping
screws to further stabilize the unit.
4
Bottom frame assembly
1. Using the top bracket subassembly, align the vertical rail with the
bottom bracket, base extension plate and base stand.
2. The mounting hole of the extension plate must be placed upward.
3. Next, install the M8 bolts and washers to secure all parts together.
4. Repeat the same step for the other side.
Top bracket subassembly
Bottom support bracket (1)
Base horizontal plates (2)
M8 hexagonal bolts (8)
Base stand with holes for anchoring (2)
3
5
4
6
3
Rack frame assembly Installation of the cable management hooks
1. At this point, place the rack in the upright position.
Note: at least two people are required for lifting up the structure, for
safety reasons.
2. Align the cable management hooks with the cable management
screw holes along the side of the rack in the preset mounting
locations, while keeping the hook openings pointing sideways. Refer
to the image below.
Anchoring of the structure
1. At this point, we highly recommend securing the base stand with
the pre-drilled holes to the floor, in order to comply with safety
requirements.
2. Use the provided anchoring bolts which are specifically designed
to stabilize and secure the unit upright to a concrete or hard surface
in your workspace.
3. Use the self-tapping screws to fasten the hooks to the rails.
16
17
M4 phillips self-tapping screws (8 or 14)
Cable management hooks (8 or 14)
16
17
9
10
11
12
M8 flat metal washers (8)
7
5
4
6
7
Anchoring bolts (4)
Split-lock washers (4)
Metal washers (4)
M10 nuts (4)
7 8
1
5
5
3

Note: the square holes on the vertical rails are numbered to easily
identify each mounting location.
8. Run your cables through the hooks to keep them accessible and
organized.
13
14
15
Equipment installation
The rack is now assembled and ready for equipment installation.
1. Do not install any equipment until you have stabilized the
structure.
2. Always load the heavier items at the bottom first, followed by the
lighter equipment at the top of the rack, for safety reasons.
3. On the already installed vertical rails, count up the square holes
and insert an M8 cage nut in each square hole, with the tabs facing
inward.
4. Repeat this procedure until all M8 cage nuts are installed in the
square holes of the front and back rails.
5. Align the equipment or component that will be mounted on the
square location where the cage nut has been inserted.
6. Proceed to insert the M8 phillips-head screws and plastic flange
washers from the inside through the vertical mounting rails and into
the nuts you installed in the previous step.
7. Tighten the screws to secure the equipment to the vertical rails.
M8 cage nuts (20 or 40)
M8 plastic flange washers (20 or 40)
M8x12mm phillips-head
screws (20 or 40)
LIGHT
HEAVY
LAST
FIRST
9 10

NotesNotes
11 12

Other manuals for Professional Series
3
This manual suits for next models
2
Table of contents
Other Nexxt Solutions Rack & Stand manuals
Popular Rack & Stand manuals by other brands

SIIG
SIIG CE-MT2P12-S1 quick start guide

Whelen Engineering Company
Whelen Engineering Company SABKT9 installation guide

Würth
Würth ZB-STAENDER-SE-F.MKS 2400 Translation of the original operating instructions

Bakker Elkhuizen
Bakker Elkhuizen BS207 installation manual

NavePoint
NavePoint 00402225 Assembly instructions

Dipol
Dipol PRB-1 installation instructions