NKE 90-60-450 User manual

Zi de Kerandré – Rue Gutemberg – 56700 – HENNEBONT – FRANCE
www.nke-marine-electronics.com
+33 297 365 685
INSTALLATION GUIDE
Loch Sounder Interface
Product reference : 90-60-450

- 2 - Loch_Sounder_Interface_um_EN_17_21
TABLE OF CONTENTS
1 PRESENTATION .................................................................................................................. 3
2 TECHNICAL SPECIFICATIONS ........................................................................................... 4
3 DIAGNOSTIC FOR 1ST LEVEL TROUBLESHOOTING. ....................................................... 4
4 INSTALLATION .................................................................................................................... 5
4.1 LIST OF ACCESSORIES ........................................................................................................... 5
4.2 INSTALLATION PRECAUTIONS .................................................................................................. 5
4.3 INSTALLATION OF THE LOCH SOUNDER INTERFACE HOUSING ..................................................... 5
4.4 CONNECTION TO THE TOPLINE BUS......................................................................................... 6
4.5 CONNECTION OF THE SENSORS .............................................................................................. 6

- 3 - Loch_Sounder_Interface_um_EN_17_21
1 PRESENTATION
The loch sounder interface allows the connection of the speedometer log sensor and the
depth-finder sensor to the TOPLINE Bus of your installation. This measurement instrument
provides on the one hand the information on speed and distance covered by the ship, and on
the other, the depth, the water temperature and the voltage of the power supply bus.
Depending on your performance requirements, you can use two types of log sensor :
- The speedometer log sensor with paddlewheel.
- The electromagnetic speedometer log sensor.
Architecture of the installation
IMPORTANT
- Read this user guide entirely before starting the installation.
- Any electrical connection on the TOPLINE bus must be carried out with the terminal box 90-
60-121. Only use TOPLINE bus cable of the type 20-61-001.
- Any intervention on the TOPLINE bus must be carried out with the installation power
switched off.
- For channel settings, please refer to your TOPLINE display guide.
Cable TOPLINE
20-61-001
GND
DATA black
12VDC white
Figure 1
log depth interface
90-60-450
log
speedomètre depth
connecting box
90-60-417
NMEA -
NMEA +
input NMEA
nke
TL 25
16.85
BOAT SPEED
APP WIND A
105-
KNOTS
DEGRES
10.50
DEPTH
METERS

- 4 - Loch_Sounder_Interface_um_EN_17_21
2 TECHNICAL SPECIFICATIONS
- Power supply : 10 to 16VDC
- Consumption : 60mA
- Tightness :IP54
- Weight : 160 g
- Operating temperature : -10°C to +50°C
- Storage temperature : -20°C to +60°C
3 DIAGNOSTIC FOR 1ST LEVEL TROUBLESHOOTING.
This chapter can help you rapidly resolve minor problems which do not require the intervention
of a specialist. Before contacting technical support, please check the troubleshooting table
below.
Problem Possible causes and solutions
The Topline installation does not detect the Loch sounder
interface The bus cable is not or is badly connected to the terminal box : check the
plugging and the connection inside the terminal box. Check the state of
the cables : they must not show any sign of wear or cut.
The surface speed displayed is 0.00, no matter what the speed
of the ship is. Check that the vaned rotor is not clogged (algae, seashells).
Check that the calibration coefficient is not set to 0.00 : see chapter 3.
The surface speed displayed is 0.00 and the water temperature
channel displays « Pan ». It may be that the log sensor is badly connected or broken. Check the
state of the cable and the connection to the box.
The depth-finder displays depth but the display flickers
intermittently.
Your depth-finder is struggling to detect the seabed ; clean the surface of
the depth-finder sensor.
The depth-finder continuously displays a constant depth :
example 2.10 It may be that the depth-finder is detecting the keel and not the seabed.
Please refer to the installation guide of the depth-finder sensor.
Your display indicates battery fault. Check the voltage of your battery with a voltmeter : the operating voltage
must be above 10VDC. Check that the battery maintains the load.
If you do not manage to solve the problem, please contact your distributor.

- 5 - Loch_Sounder_Interface_um_EN_17_21
4 INSTALLATION
4.1 List of accessories
- 15 meter bus cable fitted with a connector : 90-60-460
- TOPLINE Terminal box : 90-60-121
- Cable adapter for old version of depth-finder sensor 90-60-453.
- Cable adapter for old version of vaned rotor log sensor : 90-60-454
- TOPLINE bus connector : 90-60-465.
4.2 Installation precautions
It is recommended to mount this housing towards the bow of the ship and at a certain height, in
a location that is unlikely to get flooded.
4.3 Installation of the loch sounder interface housing
The housing of the loch sounder interface is splash-proof. It is fitted with three connector
sockets for the connection of the depth-finder sensor, the log sensor and the TOPLINE bus
cable. The housing will be mounted using four M4 screws (not included).
Figure 2
CAUTION :
- To guarantee the watertightness of the loch sounder interface, make sure the connectors
are firmly screwed onto the connector sockets.
- The connection of the sensors must be performed with the installation power switched off.

- 6 - Loch_Sounder_Interface_um_EN_17_21
4.4 Connection to the Topline bus
1. Make the bus cable run from the loch sounder interface to the TOPLINE terminal box of
your installation.
2. Connect the bus cable inside the terminal box.
If you reduce the length of the bus cable 90-60-460, strip and galvanise the wires before
connecting them inside the terminal box.
4.5 Connection of the sensors
The sensors are equipped with a 6 meter cable and a moulded waterproof connector. You will
connect the speedometer log sensor, vaned rotor or electromagnetic, onto the connector socket
marked speed sensor and the depth-finder sensor onto the depth sensor connector socket
(see figure 2).
BLANC
GND
NOIR
BLANC
GND
NOIR
12V
GND
Supply voltage 12Vdc
+
connecting box90-60-121
Figure 3 : connection to bus TOPLINE
Depth log interface
90-60-450
-
GND
DATA black
12VDC white
Ent
Esc
BOAT
SPEED
DEPTH
23.4
m
1.20
kn

- 7 - Loch_Sounder_Interface_um_EN_17_21
NOTES
_________________________________________________________________
_________________________________________________________________
_________________________________________________________________
_________________________________________________________________
_________________________________________________________________
_________________________________________________________________
_________________________________________________________________
_________________________________________________________________
_________________________________________________________________
_________________________________________________________________
_________________________________________________________________
_________________________________________________________________
_________________________________________________________________
_________________________________________________________________
_________________________________________________________________
_________________________________________________________________
_________________________________________________________________
______________________________________________________

- 8 - Loch_Sounder_Interface_um_EN_17_21
NOTES
_________________________________________________________________
_________________________________________________________________
_________________________________________________________________
_________________________________________________________________
_________________________________________________________________
_________________________________________________________________
_________________________________________________________________
_________________________________________________________________
_________________________________________________________________
_________________________________________________________________
_________________________________________________________________
_________________________________________________________________
_________________________________________________________________
_________________________________________________________________
_________________________________________________________________
_________________________________________________________________
_________________________________________________________________
_____________________________________________________
Table of contents
Other NKE Recording Equipment manuals