Nomadic NC-X2 Manual

NC-X2Install Manual
16680 N 51st Ave Units 4 & 5
Glendale, AZ 85306
(480) 576-2489
www.NomadicCooling.com/Support
Version 24013048V | 24V | 12V

NC-X2Instalation Manual Ver. 240130 2 Nomadic Cooling Co
TABLE OF CONTENTS
INTRODUCTION ..........................2
ITEMIZED PARTS LIST .....................3
IMPORTANT SAFETY INSTRUCTIONS......5
NC-X2SPECIFICATIONS ...................6
INSTALLATION INSTRUCTIONS............7
ELECTRICAL WIRING DIAGRAMS .........12
CONTROL PANEL WIRING PHOTOS ......15
TROUBLESHOOT COMMON ISSUES......17
WARRANTY INFORMATION ..............18
RETURNS, CANCELLATIONS, and
MISSING PARTS.........................19
INTRODUCTION
The NC-X2Air Conditioner (“AC unit”) is de-
signed and intended for instalation on the
roof of a recreational vehicle during or after
the vehicle is manufactured.
The NC-X2can be installed by one person with
brief help from one additional person. Reading
this instalation manual in its entirety first will
ensure the proper instalation and function of
the NC-X2.
Nomadic Cooling reserves the right to modify
appearance and specifications without notice.
Always bench test AC unit
before installing.
Check to ensure all required
parts are included (see page 3).
16680 N 51st Ave Units 4 & 5
Glendale, AZ 85306
(480) 576-2489
www.NomadicCooling.com/Support
Keep a record of the following information:
Model
Serial No.
Date Purchased
Installed By
NC-X2Rooftop AC Unit |
48V
24V
12V

Nomadic Cooling Co 3 NC-X2Instalation Manual Ver. 240130
ITEMIZED PARTS LIST

NC-X2Instalation Manual Ver. 240130 4 Nomadic Cooling Co
AC Base Plate
AC Unit / Shroud
Foam Gasket
Vehicle Roof
Crossbars
Optional X2 Trim
Ring (DIY Kit)

Nomadic Cooling Co 5 NC-X2Instalation Manual Ver. 240130
This manual contains safety guidelines and
instructions that can aid in reducing or elim-
inating the risk of accidents and injuries.
A. Recognizing Safety Information
The safety alert symbol is utilized to notify
potential physical injury hazards. To avoid
possible injury or death, follow all safety
messages that come after this symbol.
B. Understanding Signal Words
Signal words identify safety and property
damage messages and indicate the degree
of hazard seriousness.
WARNING is used for hazardous situ-
ations that could result injury (includ-
ing death, severe, moderate or minor
injury if not avoided.
NOTICE is used for situations that
could result in AC unit or vehicle
damage or unnecessary complications
in the instalation process.
HELPFUL TIP is used for useful
information or best practices.
C. Supplemental Directives
To avoid potential injury and even death,
read and follow all of the safety information
and instructions.
Read and comprehend these instructions
before installing, using, servicing, or maintain-
ing this AC unit. Poor instalation, operation,
servicing, or maintenance of this AC unit can
result in severe injury. Follow all instructions.
The instalation must comply with all appli-
cable local and national codes, including the
atest edition of the following standards:
USA
• ANSI/NFPA70, National Electrical
Code (NEC)
• ANSI/NFPA1192, Recreational
Vehicle Code
CANADA
• CSA C22 1. Parts I & II,
Canadian Electrical Code
• CSA Z240 RV Series,
Recreational Vehicles
D. General Safety Messages
WARNING - Failure to follow the subsequent
warnings could lead to death or serious injury.
• A qualified service technician MUST
install or service this product.
• Do NOT modify this product in any
way. Modifications can be extremely
dangerous and void any warranties.
• Do NOT add any devices or accessories
to the AC unit unless specifically
authorized in writing by Nomadic
Cooling Co.
IMPORTANT SAFETY INSTRUCTIONS

NC-X2Instalation Manual Ver. 240130 6 Nomadic Cooling Co
NC-X2SPECIFICATIONS
OFF-GRID AIR CONDITIONING SYSTEMS FOR VANS, RVS & RIGS
Engineered
to fit 14"x14"
industry-standard
rooftop opening.
Powerful cooling,
and 40% smaller
than comparable
units on the market!
Shroud available
in Arctic White
or Obsidian Black.
User Installation and Operation Guide
available at NomadicCooling.com
X2Spec Sheet | Ver. 231218
Remote control
included
Flush-mounted, powder coated
Obsidian Black interior faceplate.
Modern, crisp
LCD panel
22.5"
28"
Our quietest, lowest profile AC unit yet!
48V, 24V and 12V systems available
6.9"
14 "4" 4"
8.6"3.125"
14 "10 .75"
13.5"
Allow 1/8" to 1/4" placement variance
Current ECO Mode 8A 17A 27A
Current MAX Mode 15A 35A 55A
Rated Power 1,070W 900W 720W
Fuse Size 30A 50A 70A
Rated Cooling Capacity (BTU) 12,150 10,280 8,188
Power Cord Specification 10 AWG 8 AWG 4 AWG
Refrigerant R134a @ 450g ± 30g
Refrigerant Oil POE68
Speed Range 1,000 to 3,000 RPM
Weight 44 lbs
Interior Facepate Dimension 16¼" x 16¼" (flush mount)
Noise (Decibels) ≤ 60 dBa
Operation Modes Auto/ECO/MAX/Fan
Min-Max Temp Settings 54°F to 89°F
Warranty
One (1) Year + Extension Option
48V 24V 12V
MODEL
Temp Settings
pg
NC-X2Rooftop AC Unit
48V/24V/12V AW/OBS
PRODUCT:
MODEL:

Nomadic Cooling Co 7 NC-X2Instalation Manual Ver. 240130
INSTALLATION STEPS
1. The NC-X2 is designed to fit an industry
standard 14"x14" opening. If you need to
cut a rooftop opening, mark the interi-
or ceiling using the cardboard tempate
provided in the host box.
Never cover AC top fan. Do not cut
into structural beams.
When determining AC unit location,
be sure to allow for the 22.5" x 28"
shroud when positioned on the roof.
Make sure there are no electrical or
other encumbrances in the way.
2. Make sure the panned opening is
centered from all four sides. This gives
the best chance for easy instalation.
Center the opening between the ribs of the
interior ceiling.
Using the 14"x14" tempate provided, mark
the four corners with a permanent marker.
3. Drill each corner of your markings
through the interior roof using a 1/8” bit.
On the exterior rooftop, use painter’s
tape and a permanent marker to draw
your 14"x14" cutlines from hole to
hole. Make multiple passes with the
permanent marker.
If you make a mistake repace the
tape and try again. Measure repeat-
edly to make sure your lines create a
perfect 14"x14" square.
4. Cut on your lines on the rooftop using a
jig saw, nibbler or cutting wheel.
Use a sander or file to smooth out the
rough edges after cutting.
14”
14”
14”14”
Interior Ceiling
Ceiling Ribs
14"x14" opening
centered between ribs
Vehicle Front
Interior Ceiling
Front of Vehicl
e

NC-X2Instalation Manual Ver. 240130 8 Nomadic Cooling Co
5. Paint around the edges of the cut roof
opening to prevent rust. You can use any
color rust-preventative paint.
6. Remove tape and clean surface.
7. Remove waterproof gasket from box.
Make sure area/paint is clean, dry and
clear of all debris.
Use alcohol wipes or PrepSol to
remove oil or wax from vehicle roof.
If pacing gasket over a high or uneven
roof surface, remove small amounts of the
14"x14" gasket to match roof contours.
Use bade to cut away gasket
if needed.
Remove gasket adhesive only after
making any necessary cuts. Pace the
gasket sticky side down.
8. Apply polyurethane adhesive seaant (in-
cluded in DIY kit) around 14"x14" gasket.
9. Gently pace AC unit on roof over gasket.
Inner gasket dimension is 14"x14", outer
dimension is 16.25"x16.25". Measure side-
to-side until centered on all four sides.
Be careful not to puncture, rip
or tear the gasket with AC unit’s
mounting bolts.
Do not put adhesive on top of gasket.
Do not damage electrical components
when pacing AC unit.
10. Adhere optional leveling strip behind the
foam gasket.
Exterior Roof
Exterior Roof
URETHANE ADHESIVE
CUTAWAYS FOR ROOF RIDGES
Leveling strip
14” x 14” gasket
Adhesive side

Nomadic Cooling Co 9 NC-X2Instalation Manual Ver. 240130
11. From inside the vehicle add the crossbars
to attach AC unit to the roof. Locate the
mounting bolts, washers and nuts.
Do not use electric drill on crossbars.
12. If possible with your particuar build, we
recommend using a trim ring to provide ad-
ditional support around the rooftop open-
ing. The DIY kit includes a Nomadic Cooling
X2trim ring. Professional upfitters typically
create their own custom trim rings.
13. Add the nut, washer and lock washer to
each of the four bolts that screw into the AC
unit base pate through the crossbar.
Hand-tighten all four bolts to the AC unit.
Do not over tighten! Once all four bolts are
hand-tight, torque the lock nuts to 3.7 lb to
secure the crossbars to the AC unit, and the
AC unit to the roof.
With optional Trim Ring:
If NOT using a trim ring, you may use
the optional pastic spacer for the two
rear bolts, between the crossbars and
the AC unit base.
Without Trim Ring showing optional spacer:
During the instalation process, if the
locking nut is installed too tightly, it
may cause deformation of the AC unit
base pate. The spacer can pay a limit-
ing role, with any excess locking force
acting on the spacer instead of the AC
unit base pate.
A sticker found on the bag
of bolts may say to tighten
to 5.0 lbs. of torque, please
disregard and use the rec-
ommended 3.7 lbs.
AC unit will help to create pressure.
When securing AC unit to the vehicle,
increased compression of the gasket
will level the unit against the roof. No
light should be visible.
Do not over-tighten mounting bolts.
Bolts will rotate if over-torqued,
and may break from AC base pate.
Over-tightening will void warranty.
FrontRear
Trim Ring
Crossbar
Gasket
Spacer
Back of AC unit
Hand tighten all 4
bolts to crossbars,
then torque the
nuts to 3.7lbs (~5nm).
Crossbar
Washer
Lock Washer
Nut (fat side up)
Bolt
Pastic Spacer
(optional if not
using Trim Ring)
Vehicle Roof (cutout)
Gasket
Trim Ring (Optional)
AC Base Pate
FrontRear

NC-X2Instalation Manual Ver. 240130 10 Nomadic Cooling Co
Our gaskets are used for vibration
absorption. It is very high density and
can’t be compressed more than 10%.
Use gasket tension to control AC unit’s
distance from roof surface.
AC unit should be resting on foam gasket
and not on the vehicle’s roof.
Over compression of the unit to the
roof may cause the internal fan to rub
against the fan housing.
Be sure the fan bades rotate freely
prior to starting the unit.
12. Install and connect LCD control panel
before connecting to power to avoid
blowing internal fuse.
An appropriately-sized fuse must be
paced between your power source
and the AC unit:
48V = 30A fuse
24V = 50A fuse
12V = 70A fuse
13. Connect DC power wires to unit. “Quick
Connection to DC Wiring Harness” included.
12V systems use an Anderson connector,
24V and 48V systems use a simiar Ander-
son style connector.
Make sure wiring is appropriately
sized and is no smaller than 4AWG.
14. Attach LCD control panel and AC
wiring harnesses.
15. Attach thermostat wires to control panel
wiring harness.
Details of control panel connections are
shown in electrical diagram on page 12.
Condenser is always to the left of the
back wire. Be careful not to break
these wires.
16. Use the foam separator to properly sepa-
rate hot air from cold air as it enters and
exits the AC unit.
AC unit centered
on foam gasket
Foam separator
AIR IN AIR OUT
To AIR-OUT sensor
To Control Panel

Nomadic Cooling Co 11 NC-X2Instalation Manual Ver. 240130
17. Use heat resistant tape to secure the air
separator in pace. Use your best judg-
ment on how much tape to use and
where to adhere it, as every instalation is
different. The tape helps the air separator
keep the warm and cool air separated.
18. Test all connections between the
power source and the unit for excessive
heat during normal operations.
19. Install facepate. Line up the facepate
vents with the air-out fan openings in the
AC base pate. Use 8 screws (back screws
were included in instalation kit) that will
match your vehicle interior to secure the
facepate to the ceiling.
The facepate does not screw into the
AC unit base. It attaches (flush mount-
ed) to the vehicle’s ceiling directly.
Congratulations!
Your Nomadic Cooling X2AC unit rooftop
instalation is complete. Now...
Exploded NC-X2Components
Vehicle Ceiling

NC-X2Instalation Manual Ver. 240130 12 Nomadic Cooling Co

Nomadic Cooling Co 13 NC-X2Instalation Manual Ver. 240130

NC-X2Instalation Manual Ver. 240130 14 Nomadic Cooling Co

Nomadic Cooling Co 15 NC-X2Instalation Manual Ver. 240130
Shown below is a properly wired LED Control Panel for X2 (12V and 24V) models.
Red
Red White
Back Green
Back and
Back wires to
Thermistor
Sensor (Air In)
Back and
Back/White Striped
wires to Thermistor
Connector (Air Out)
24V | 12V
Yellow Blue

Shown below is a properly wired prototype Control Panel for X2 48V model.
48V
Red Blue Blue
Green
Back
48V Power Supply Brushless Fan Condensor Fan
Compressor
Voltage Monitoring
White White
Red
Back & Back
to thermistor
sensor (Air IN)
White & White
to thermistor
connector (Air OUT)
Red
PROTOTYPE ONLY

Nomadic Cooling Co 17 NC-X2Instalation Manual Ver. 240130
Troubleshoot Common Issues
All of our AC units are bench tested before
leaving the Nomadic Cooling warehouse. In
the unfortunate event that your AC unit is
not working properly, you should consider
some of these more common problems that
our technical support team encounter.
1. Power issues. Using a voltmeter, measure
the voltage the AC unit is receiving from
the power source. A drop in expected
power will cause a drop in cooling capac-
ity for the AC unit, just as it would cause
a light bulb to not glow as brightly.
A. If the voltage getting to the AC unit is
low, the first thing to consider is the dis-
tance from the power source to the AC
unit. Voltage loss in wires increases as the
distance grows. Our AC unit power cord
specifications are conservative, but if the
distance is greater than 15-20 feet, it may
be necessary to use a thicker gauge wire.
If the wiring distance is not an issue, you can
check the following:
B. Check the fuse or breaker, and any other
inline components between your power
source and the AC unit. Check the wiring
connections to and from these compo-
nents. Ensure that your fuse or breaker
are properly set, inspect the wiring in and
around such components for any cracks
or looseness.
C. Check the wires from your power source
to your AC unit. While running these
wires through a vehicle’s framework,
it can be necessary to twist and wrap
around obstacles, or feed them through
narrow spaces, often with sharp edges
exposed. This can result in damage to
the wires or insuation, which will cause a
grounding or short, and a drop in amper-
age to the AC unit.
2. Are the Crossbar Bolts are too long for
your build? Every build is different, and
if you find that the crossbar bolts are too
long, you can use a cold saw, bandsaw,
grinder or hacksaw to trim them down to
the length you need.
Remember to wear safety goggles!
Thread the nut before cutting the bolt
and then use it to re-form the thread
after cutting.
If you need to contact technical support...
Every system is different, so it is extremely
helpful (if not necessary) for our support
team to have photos of your setup to help
troubleshoot a problem. Please be prepared
to take any requested photos and send
You can initiate support requests by sending
Or you can call (480) 576-2489. Our support
team attempts to respond as soon as possi-
ble and we strive to always respond within
24 hours Monday through Friday.

NC-X2Instalation Manual Ver. 240130 18 Nomadic Cooling Co
Nomadic Cooling is dedicated to delivering top-quality
products coupled with outstanding customer service. We
provide an industry-leading warranty for our products to
ensure your satisfaction and peace of mind. Technical
support is avaiable for the lifetime of any X Series AC
unit. Please review the following warranty policy.
1. Warranty Period
All X Series AC units are covered by a one year war-
ranty period which begins on date of purchase. An
optional one-year extended warranty is avaiable if
purchased prior to initial warranty period expiration.
Note: X3AC units purchased prior to December 1, 2023
are covered by an initial two-year warranty.
2. Warranty Coverage
During the warranty period, the Nomadic Cooling Co
Warranty will cover all X Series AC units that experi-
ence any defects due to manufacturing or workman-
ship issues. The customer shall be responsible for all
shipping costs to get the X Series AC unit to and from
Nomadic Cooling for inspection, repair, repacement
or upgrade.
3. Optional Extended Warranty (X2 and X3)
You may purchase a one-year extended warranty for
any X Series AC unit which provides the same cover-
age as described above (#2).
4.Optional Refundable Core Charge
If you wish to have a repacement X Series AC unit
shipped prior to Nomadic Cooling receiving the warran-
tied unit, a core charge of up to 50% of the Manufactur-
er’s Suggested Retail Price (MSRP) may apply. This core
charge is intended to ensure the return of the warran-
tied unit to Nomadic Cooling. The core charge will be
added to the purchase price of the repacement unit
and is refunded upon Nomadic Cooling’s receipt and
evaluation of the returned unit. If the warranty depart-
ment determines that a defect was due to Nomadic
Cooling’s fault, the core charge will be refunded in full.
5. Exclusions and Limitations
The following are not covered by the warranty:
• Damage caused by misuse, negligence, accidents,
or unauthorized modifications.
• Damage resulting from improper instalation, main-
tenance, or storage.
• Damage caused by natural disasters, fire, water, or
any other external factors beyond our control.
• Normal wear and tear, cosmetic damages, or minor
imperfections that do not affect the functionality
of the product.
• Warranty, including an optional extended warranty,
is non-transferable.
6. Labor Exclusion
Nomadic Cooling’s warranty policy does not cover any
abor costs associated with the inspection, repair, or
repacement of an X Series AC unit. Any additional ex-
penses reated to abor, including but not limited to
instalation, removal, or troubleshooting, shall be the
sole responsibility of the customer.
7. Warranty Caims
To initiate a warranty caim, please e-mail or call us.
Our representatives will guide you through the neces-
sary steps and provide instructions on how to proceed
with the warranty caim.
Please note that this warranty policy is subject to the
terms and conditions stated herein and may be sub-
ject to change without prior notice. Nomadic Cooling
reserves the right to determine the validity of all war-
ranty caims and to make the final decision regarding
repairs, repacements, or refunds.
For warranty caims, additional information
or any questions, please contact us at:
Support@NomadicCooling.com
or call us at (480) 576-2489.
SERIES
DC-Powered Rooftop AC Units
WARRANTY POLICY
For X Series DC-Powered Rooftop AC Units

Nomadic Cooling Co 19 NC-X2Instalation Manual Ver. 240130
Returns
Nomadic Cooling will gadly accept returns
within 30 days of acceptance of order. Please
e-mail Info@NomadicCooling.com or call
(480) 576-2489. Any returns after 30 days are
subject to prior approval.
Only items in their original condition with all
packaging, accessories, instruction manuals,
warranty cards, and UPC codes will be accept-
ed for return.
A 15% restocking fee will be assessed for all
return orders. Customers are responsible for
the cost of shipping of any product returned
to Nomadic Cooling. We are happy to arrange
for return shipping using our provider rates,
or shipping can be arranged independently.
Returns must include a tracking number.
If a returned product arrives at Nomadic
Cooling with damage due to mishandling,
poor packaging, or in otherwise unusable con-
dition for resale, then an additional fee may
be assessed.
Products should be returned to:
Nomadic Cooling Co
16680 N 51st Ave Unit 4-5
Glendale, AZ 85306
Due to some products being shipped direct-
ly from the manufacturer, please check with a
Nomadic Cooling employee where to send all
other returns.
Returned products will be assessed for dam-
age upon receiving at Nomadic Cooling.
Refunds will not be processed until the
product is received, inspected, and/or tested
by Nomadic Cooling.
All refunds will be processed back to the
original payment method and/or store credit.
Order Cancelations
If you wish to cancel your order for any rea-
son, please let us know as soon as possible.
Please e-mail Info@NomadicCooling.com or
call (480) 576-2489.
If you are canceling before the order has
been shipped, then we will process a refund
back to the original payment method. If you
are canceling after the order has been ful-
filled, then the cancelation will be processed
as a return and is subject the restocking fee
and shipping costs. If applicable, you will be
responsible for any “stop and return” fees.
Missing Items
Upon receiving your order from Nomadic
Cooling, please immediately open the pack-
age and inspect the contents to ensure all
items from the order have been included. If
you suspect that an item is missing or the in-
correct item was sent, please notify a Nomad-
ic Cooling employee ASAP so we can assess
the order. If you fail to notify Nomadic Cool-
ing within 14 days of accepting an order with
missing or incorrect items, then you will be
responsible for shipping costs for the missing
or incorrect item(s).
To better prevent orders with missing or
duplicate items, and for ease of tracking,
Nomadic Cooling will only be shipping orders
once all items in the order are ready for ship-
ping. Nomadic Cooling will not send partial
shipments. Exceptions may occur when spe-
cifically requested by the customer and/or
item(s) in the order are on backorder. Prod-
ucts are shipped the same day they are pack-
aged and ready, unless requested otherwise.
RETURNS, CANCELLATIONS AND MISSING ITEMS
Other manuals for NC-X2
1
Table of contents
Other Nomadic Air Conditioner manuals
Popular Air Conditioner manuals by other brands

Gree
Gree GWH09AB-D3DNA1D/I Service manual

Carrier
Carrier ROOM AIR CONDITIONER operating manual

Fujitsu
Fujitsu AGYG09LVCB Service manual

Sharp
Sharp CVP12PX - Ha Sh 11500 Btu Portable Air... Installation and operation manual

Frigidaire
Frigidaire 220218A007 use and care manual

Mitsubishi
Mitsubishi Mr.Slim PKA-A-GA installation manual