Nomadic NC-X3 User manual

Rooftop Air Conditioner
Operation Manual
Nomadic Cooling NC-X3

Improper operation or maintenance of the rooftop parking air conditioner may
cause adverse consequences which in turn may cause damage to vehicle
components To install and maintain rooftop parking cooler Nomadic training
courses corresponding technical documents professional tools and special
equipments are required Only Nomadic’s original accessories are allowed
It is not suggested to conduct operation and maintenance of the product without
completion of Nomadic training lacking of corresponding qualification for working
on air conditioning system or necessary technical documents tools and outfits
Read and comply with warnings and notes in these installation and operation
instructions of this product
Reminder :
To guarantee better comfort effect it is preferable to cool down cabin via the
original air conditioning system in vehicle before starting parking air conditioner
only for stationary use

Contents Included
# Items Quantity
11V or V Air Conditioning Unit
2Interior Control Panel
3Remote
4Metal Washers Large
5Metal Lock Washers
6Mounting Bolts Large
# Items (cont) Quantity
Mounting Nuts
814 x 14 Waterproof Gasket
914 x 14 Interior Mounting Brace (Metal
Powder Coat)
10 Interior Vent Screws Small in Black Finish
11 600g R134a Refrigerant (Pre Filled)
R134A
C C
H
F F
H
F
F

Control Panel Legend
ON-OFF: Press this button to switch the device ON or OFF
Mode: Push this button to switch between the modes; Auto
Eco and Power
Airflow: Each push on this button corresponds to a cycle
through 5 different airflow levels
Auto 78 ºF: Pressing this button enables automat-
ic management towards ºF
Temperature “+”: Each push of this button corre-
sponds to the increase of ºF of temperature
Temperature “-”: Each push of this button corre-
sponds to the decrease of ºF
of temperature
Display Window: Display temperature airflow
voltage error codes and ambient temperature
Infrared Signal: Acceptance of infrared signal
from remote controller by users
Low-Voltage Protection Function
Settings: Long press on “ºF” button until screen
starts blinking adjust low-voltage cutoff value (de-
fault value is 11V ranging 9 -11V) via Temp “+”
or “-” button and then long press on “ ºF” button
again for 5 seconds
In order to ensure the usage time it is
recommended to use the battery after it is fully
charged
1.
2.
3.
4.
5.
6.
7.
8.
7. Display
2. Mode
3. Airflow
8. Infrared
5. Temp “+”
1. ON-OFF
4. Auto 78ºF
6. Temp “-”

Remote Control Description
. ON-OFF: Turns unit on and off
Power Mode is used for fast cooling
Eco Mode is used when resting or reading
is preferred
In Power Mode the default airflow is the biggest with the
manual adjustment
In Eco Mode compressor is running in low frequency air-
flow is defaulted as smallest with manual adjustment
Note: Strong recommendation for Power Mode less than
20 minutes Long time operation will significantly shorten
the duration of use
When cabin temperature is below ºC Auto Mode
is preferred
In different modes users can adjust the air volume
according to their needs
Please set it according to your own needs Above notes are
only for reference
Timer: After timing Temp “+” Temp “-” set the time 05
hour one level up to 10 hours press the timer key again
timer cancellation
Temp Query: Cycle switching between ambient
temperature and evaporator surface temperature
Voltage Query:Displays Voltage Reading
Temp “+” : Temperature Increase
Temp “-” : Temperature Decrease
Airflow “+” : Increased Air Speed
Airflow “-”: Decreased Air Speed
1 Auto Mode:Automatically sets thermostat to 78º
Mode:Eco Normal Powerful
(The current product status is in the selected heating and
ventilation mode only the indoor blower works)
Error Codes and Trouble Shooting
Failure analysis of no cooling or poor effect:
() The power cord connected is too long and too thin
Poor connection at connector
() No refrigerant or insufficient refrigerant
() Eco mode is used when the temperature is
too high
() Compressor or condensing fan does not work
() The evaporator or condenser is dirty or blocked
A
S
E
ON-OFF Timer
Mode
Temp “-”
Airflow “-”
1 Auto Mode
Temp Query
Airflow “+”
Temp “+”
Power Mode
Eco Mode
Voltage Query

Common Fault Code Processing Method:
1 The battery power is insufficient and under voltage E2
() Check the battery for aging and replace it
() If the battery is not fully charged it needs to be
charged
() Connect the negative pole of the power line to
the metal or the generator reconnect the wirings
or harness
2 Pressure Fault (System leakage) E4:
-Refrigerant leakage or poor heat dissipation
3 Sensor Fault E0 or E1:
() Check whether the plug-in is loose and re-insert
it tightly
() Sensor quality problem replace the sensor
4 High current protection F6 electronic fan fault F7
() Check the condenser heat dissipation whether
the surface is dirty and blocked
() Check whether the terminal or plug-in of the
power line is loose
() Check if the plug-in of the fan is loose and plug it
in again
() Condenser fan failure replace the fan

Code Description Troubleshooting
E0 Inlet temp sensor fault Check sensor connector
E1 Outlet temp sensor fault Check sensor connector
E2 Low Voltage Check battery or harness
E3 High Voltage Check battery or power
E4 Pressure (system leakage) Check R134a leakage
F0 Disconnected/Blocked compressor Check cooling fan working or not / R134a overcharge
F1 Compressor driver overheat Check cooling fan working or not / ambient>55ºC
F2 Compressor driver wire low-voltage Check harness false connection or not
F3 Compressor driver over voltage Check wire false connection
F4 Compressor driver phase absence Check wire false connection
F5 Driver output overload Check wire false connection
F6 Driver output over current Check cooling fan working or not / ambient>55ºC
F7 Cooling fan fault Check cooling fan working
Ways to deal with the above code: Turn off the power and turn on the machine in 5 minutes If the fault is not
solved please refer to the maintenance manual or contact the local dealer

Maintenance
In order to ensure the normal operation of the air
conditioner please pay attention to the
routine maintenance:
() When idle for a long time please remove the positive
and negative power lines at the battery end and pay
attention to the sealing and to avoid negative connection
direct to ground so as to avoid battery damage caused by
long-term electrification (the power line must be connected
to the battery and it is strictly forbidden to connect negative
direct to ground or connect the generator)
() The air conditioner needs to be maintained every 3
months (cleaning evaporator and condenser checking
internal and external circuits); the maintenance cycle
should be shortened appropriately in special working
conditions such as dusty and high temperature
environment Refer to table 7 of the maintenance manual
for product maintenance
() It is not recommended to install generators solar
energy and other external charging equipment
Discaimer
() We provide installation videos and installation
Instruction users must install strictly in accordance with
the video and instructions If the user fails to install in
accordance with the installation video and instructions
provided human failure or damage and other accidents
occur the user shall bear the responsibility the
maintenance and material costs caused by the user shall
be paid separately and our company will not bear
any responsibility
() The user must pay attention to safety issues during
the installation process in case personal safety issues
occur the user must bear the responsibility
() If the user changes the air conditioning privately or
the replacement of parts and components that are not
the original happens the user shall bear the
responsibility of the caused damage to the air
equipment and personal safety issues our company will
not bear any responsibility

TOP
BOTTOM
FRONT
SIDE
Nomadic AC Dimensions

Contact Information
Nomadic Cooling Co.
Address: 6680 N 51st Ave Unit 4&5 Glendale AZ 85306
Hours: Monday 9AM-5PM
Tuesday 9AM-5PM
Wednesday 9AM-5PM
Thursday 9AM-5PM
Friday 9AM-5PM
Saturday CLOSED
Sunday CLOSED
Phone: (480) 576-2489
Email: info@nomadiccooling.com
Website: Nomadiccooling.com
YouTube: NomadicCooling
Instagram: @NomadicCooling
Other manuals for NC-X3
3
Table of contents
Other Nomadic Air Conditioner manuals
Popular Air Conditioner manuals by other brands

Midea
Midea BREEZELESS Technical manual

Nordyne
Nordyne WARRCOIL01 quick start guide

Carrier
Carrier 50VL-D installation instructions

Frigidaire
Frigidaire FAA063P7A16 Use & care manual

Mitsubishi Electric
Mitsubishi Electric Mr. SLIM PKA-M-LAL Series installation manual

Defy
Defy 059 044 installation instructions