4Series EPC-30 DC-Converter Board Replacement Kit
E1999 Nordson Corporation
All rights reserved
237 546A
Issued 4/99
Manual 66--EPC30--IS--04 (formerly 46-422)
Follow this procedure to reinstall the operator panel assembly and the
terminal block cover.
1. Hold the operator panel assembly above the main control unit while
you connect the serial port cable to X5 on the main control board and
the wiring harness to X3 on the new dc-converter board.
2. Secure the operator panel assembly to the mounting plate using the
screws you removed earlier.
3. Restore power to the system and resume normal operation.
To order parts, contact the Nordson Customer Service Center or your
local Nordson representative. Use the following parts list to describe and
locate parts correctly. See Figure 3.
Item Part Description Quantity Note
—772 031 Service kit, dc-converter board —
1982 017 SScrew, pan-head, recessed, M3 x 8 mm 4
2------ SDC-converter board 1
3182 300 SPlug-in connector, 20-pin 1
4182 301 SPlug-in connector, 4-pin 1
5983 426 SLock washer, M, external, M3 1
5742111A
2
1
3
4
5
Fig. 3 DC-Converter Board Service Kit Parts
Original copyright date 1999. Nordson and the Nordson logo are registered trademarks of Nordson Corporation.