Nortek Security & Control 500 Series User manual

1
PS15EMZ5-1 PLUG-IN MODULE
The GoControl™ family of Z-Wave® certified wireless lighting products (smart LED
fixtures, bulbs, switches, dimmers, outlets, plug-in modules) Control Products (thermostats,
irrigation controller and garage door controller)and Sensors (flood, leak, alert sounder,
motion sensor and door/window sensor) bring a new level of intelligent wireless Home
Automation capability to commercial and residential environments.
The Z-Wave wireless protocol is an international wireless standard for remote home
automation, security and other applications. This product can be included and operated in
any Z-Wave network with other Z-Wave certified devices from other manufacturers and/or
other applications. All non-battery operated nodes within the network will act as repeaters
regardless of vendor to increase reliability of the network.
GoControl Z-Wave products are easy to install, are Z-Wave certified, and allow dealers to
create an integrated wireless network with nearly limitless expansion and interoperability
with security, energy management, home entertainment, appliances, and more.
The PS15EMZ5-1 is a simple Plug & Play Home Automation device that lets you control
any lighting or small appliance while monitoring the amount of energy being used.
Bright multi-colored LEDs provide an instant indication of the energy being used while
simultaneously reporting this information to your Z-Wave hub that may be used for energy
monitoring and analysis.
Z-WAVE PLUS FEATURES
The PS15EMZ5-1 contains a Z-Wave 500 Series Module that supports Z-Wave Plus®
features. A Z-Wave certified portable or stationary Controller can communicate with the
Z-Wave 500 Series Module.
Depending on the capability of the Controller or gateway software, the following operations
can be performed with the PS15EMZ5-1. Refer to the Controller or gateway manual for
details.
• Turn the load ON and OFF.
• Add or Remove the PS15EMZ5-1.
• Assign the PS15EMZ5-1 to a specific Group/Scene and/or to include the load as part of ALL ON or
ALL OFF system commands.
• Over-the-air firmware update by the gateway or static Controller.
• Lifeline function which automatically notifies the associated modules and the network that a
manually reset device is no longer in the network, thus, the corresponding association becomes
invalid.
• Monitors the amount of energy being used and reports the current usage to the Z-Wave controller
INSTALLATION
Adding to a network:
Refer to your Controller operating instructions to add this switch under the command of
the Wireless Controller.
1. With your Controller in Discovery or Add Mode, tap the button on the face of the outlet.
The LED will blink slowly when in ADD Mode.
2. You should see an indication on your Controller that the “device was added” to the
network and the LED will stop blinking.
3. The device will appear in the list of Switches. It should display as a switch.
If the Controller/Gateway shows the addition failed, repeat Steps 1-3.
✓NOTE: If you have trouble adding the PS15EMZ5-1 to a group it may be that the
Home ID and Node ID were not cleared from it after testing. You must first “RESET UNIT”
to remove it from the network. Although adding it to a group includes it in the network,
removing it from a group does not remove it from the network. If removed from a group,
it functions as a repeater (only). “RESET UNIT” removes it completely from the network.
To Reset Unit (If Required):
In the event that your primary Controller is lost or otherwise inoperable, to reset the
PS15EMZ5-1 and clear all network information, follow these steps:
1. Tap the button on the face of the outlet five (5) times.
2. Press and hold the button for 15 seconds. The LED will increasingly blink faster to
indicate that a Reset is taking place.
Removing from a network:
The PS15EMZ5-1 can be removed from the network by the Controller/Gateway. Refer to
the Controller operating instructions for details.
1. Set the Controller into Removal Mode and follow its instruction to delete the
PS15EMZ5-1 from the Controller.
2. Remove the switch by tapping the button on the face of the outlet 2 times. The LED will
begin blinking slowly for 10 seconds indicating that it has been removed.
3. You should see an indication on your Controller that the “device was removed” from
the network.
BASIC OPERATION
Local Control
The button on the PS15EMZ5-1 allows the user to:
• Turn the attached load on or off.
• Execute configuration and control features.
Night Light
To act as a night light, the LED on the PS15EMZ5-1 can be configured to turn ON when
the load attached is OFF. See “CONFIGURATION” section.
Energy Monitoring
PS15EMZ5-1 reports the total accumulated Kilowatt Hours (kWh) and the instantaneous Watts
being consumed by the load.
Parameter LLength Valid ValuesConfiguration Options
13 2 Byte
Decimal
0 Automatic reporting OFF
1-255 Number of minutes between automatic reporting
(Default = 6)
Configuration Parameter 13 configures the rate at which the energy readings are reported. If the
maximum kWh value that can be reported is reached (21,474 kWh), then it will remain at the
maximum level until reset to 0 using the Controller software.
To reset, the total accumulated kWh used by the PS15EMZ5-1 the Z-Wave controller needs to
send a reset command at the request of the user. It will also be reset if the PS15EMZ5-1 is
excluded from the Z-Wave network.
The Watts reading provides the immediate reading of the power being consumed by the load.The
Watts reading takes several seconds to settle so wait a few seconds before reading the energy
value when the state of the switch (on / off) has changed.
✓NOTE: If Power Monitoring, see Configuration Section below, is turned OFF the
PS15EMZ5-1 will not report any energy use.
Remote Control
The PS15EMZ5-1 will respond to BASIC and BINARY_SWITCH commands that are part of
the Z-Wave system. Refer to your Controller’s instructions as to whether your Controller
can transmit those commands.
Protection Mode
The PS15EMZ5-1 supports Protection Mode that is used to disable the button on the front
of the device. This eliminates inadvertent activation of the switch. To enable Protection
Mode, press the button on the PS15EMZ-1 three times quickly. The LED will blink Purple
twice showing that Protection Mode has been enabled. When Enabled the only way to turn
ON or OFF the PS15EMZ5-1 is through the Z-Wave controller or Mobile app. If the button
on the PS15EMZ5-1 is pressed, the LED will blink Purple twice and have no impact on the
attached device. To exit Protection Mode, press the button three times.
Associations
The PS15EMZ5-1 supports one Group with one (1) Node for lifeline communication. Group
1 must be assigned the Node ID of the Controller to which unsolicited notifications from the
PS15EMZ5-1 will be sent. The Z-Wave Controller should set this Association automatically
after inclusion. You can associate up to five Z-Wave devices to Group 1.
For instructions on how to “set Lifeline Association” please refer to your Controller
instructions.
PS15EMZ5-1
Z-Wave Radio Frequency (RF) Controlled, 120 VAC
15 Amp, Plug-In Switch Series 500
NOTE: This unit must be added to the Network only where it will be permanently installed. The proper operation of this node in the mesh
network is dependent on it knowing its location with respect to other nodes. You cannot “test bench” configure this unit, then install.
Bottom of Appliance Module
showing 3 prong plug-in
Copyright © 2018 Nortek Security & Control LLC
PRINTER’S INSTRUCTIONS:
INSTR,INSTL,PS15EMZ5-1 P/N 10008371 E, GO CONTROL ; INK: BLACK; MATERIAL: 20# MEAD BOND; SIZE: 8.500” x 11.000”; TOLERANCE ± .125”, SCALE: 1-1 - PAGE 1 OF 2

2
Removing Associations
To remove the Associations, if the Controller has recognized the Associations, refer to the Z-Wave
Controller’s instructions on how to remove Associations. If the Controller has not recognized the
Associations, removing the PS15EMZ5-1 from the Z-Wave network will eliminate the Associations.
ADVANCED OPERATION
All On/All Off
The PS15EMZ5-1 supports the ALL ON / ALL OFF commands. The PS15EMZ5-1 can be set to
respond to ALL ON and ALL OFF commands four different ways.
Refer to your Controller for information on how to set the PS15EMZ5-1 to operate in the manner
you desire. Some Controllers may be only able to set certain settings of ALL ON/ALL OFF response.
The four different ways the PS15EMZ5-1 can be setup to respond to ALL ON and ALL OFF
commands are:
1. Responds to ALL ON or the ALL OFF command.
2. Responds to ALL OFF command but will not respond to ALL ON command.
3. Responds to ALL ON command but will not respond to ALL OFF command.
4. Responds to ALL ON and the ALL OFF command.
CONFIGURATION
The PS15EMZ5-1 supports the Configuration command. Each unit can be configured to
operate slightly differently than how it works when you first install it.
Using the Configuration command you can configure the following:
LED Intensity
You can set the intensity of the LED to fit the environment the PS15EMZ5-1 is being used
in from OFF to full brightness. This is done by changing Parameter 2
Parameter Length Valid Values Configuration Option
21 Byte
Decimal 0 - 100 0 = OFF
1 = Very dim
100 = Full Brightness (default)
Power Monitoring
The PS15EMZ5-1 provides a visual display of the amount of energy being consumed when
the switch is turned ON by illuminating the LEDs in one of 5 different colors.
Energy Use LED Color
0 to 0.02 Amps White
0.02 to 2 Amps Green
2 to 5 Amps Blue
5 to 10 Amps Yellow
Over 10 Amps Red
The Power monitoring can be turned OFF utilizing Parameter 11. When turned OFF, the
PS15EMZ5-1 will no longer illuminate the LED to indicate any energy use and periodic
reports to the hub on energy use will also be turned OFF.
Parameter Length Valid Values Configuration Option
11 1 Byte
Decimal
0 Power monitoring OFF
1 Power monitoring ON (Default)
The duration the LED will change color to indicate the amount of energy being used can
be set using Parameter 12. After displaying the “energy used” color, the LED will revert to
OFF or ON (white) as determined by configuration parameter #3
Parameter Length Valid Values Configuration Option
12 2 Byte
Decimal
1 - 254 Number of seconds LED displays
power level usage. Default = 60
255 Power level usage continuous ON
Night Light
Parameter Length Valid Values Configuration Option
31 Byte
Decimal
0LED ON when the load is ON, and OFF when the load
is OFF
1LED OFF when the load is on, and ON when the load
is OFF
2 LED is always ON
3 LED is always off (default mode)
Local Device Configuration
The PS15EMZ5 features a button driven method to turn the nightlight feature ON/OFF. To
enter this mode, tap the button four times in a row. The LED will blink Red and White and
then switch to a blinking blue pattern to signify the user may change the nightlight mode.
While in this local configuration mode, a single tap will toggle (turn ON or OFF) the Nightlight
feature of the device. A blinking White/Blue pattern denotes the Nightlight feature is ON. A
blinking White/Black pattern denotes the Nightlight feature is OFF. Once the desired setting
is set; tapping the button four times again will exit the mode. Alternatively, waiting 10
seconds without pressing the button will automatically exit this local configuration mode
feature. The LED will blink Red/White again to signify exiting the mode.
Over-The-Air (OTA) Update
A compatible Z-Wave Hub may initiate an over the air firmware update. The device will pause
operation and blink an alternating pattern of blue and green. When the OTA is complete, the
device will reboot and continue operation. Operation will continue with all previously configured
parameters..
Resetting to Defaults
Each configuration Parameter can be set back to its default setting by setting the default
bit in the Configuration Set command. See your Controller’s instructions on how to do this
(and if it supports it). All configuration commands will be reset to their default state when
the PS15EMZ5-1 is excluded from the Z-Wave network by using the Controller to reset
the node.
SPECIFICATIONS
Power: 120 VAC, 60 Hz
Signal (Frequency): 908.42 MHz / 916 MHz
Maximum Load: Resistive: 15 amps (1800 watts) maximum, 120 VAC
Range: Up to 130 feet (line of sight)
NOTICES
Z-Wave®and Z-Wave Plus®are registered trademarks of Silicon Labs and its subsidiaries in the United States and
other countries.
Terms and Conditions pertaining to the sale of this Nortek Security & Control wireless mesh network product are available
at http://nortekcontrol.com/terms_conditions.php
REGULATORY INFORMATION
We, Nortek Security & Control, LLC of 1950 Camino Vida Roble STE 150, Carlsbad, CA 92008,declare under our sole
responsibility that the device, PS15EMZ5-1 complies with Part 15 of FCC rules.
This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device
may not cause harmful interference, and (2) This device must accept any interference received, including interference
that may cause undesired operation.
FCC Notice
This equipment has been tested and found to comply with the limits for a ClassB digital device, pursuant to Part 15 of
the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential
installation.
This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance
with the instructions may cause harmful interference to radio communications. However, there is no guarantee that
interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or
television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to
correct the interference by one or more of the following measures:
• Reorient or relocate the receiving antenna.
• Increase the separation between the equipment and receiver
• Connect the equipment into an outlet on a circuit different from that to which the receiver is
connected
• Consult the dealer or an experienced radio/TV technician to help.
Changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority
to operate the equipment
IC Notice
This Class B digital apparatus complies with Canadian ICES-003
Cet appareil numérique de la classe B est conforme à la norme NMB-003 du Canada. Le présent appareil est conforme
aux CNR d’Industrie Canada applicables aux appareils radio exempts de licence. L’exploitation est autorisée aux deux
conditions suivantes : (1) l’appareil ne doit pas produire de brouillage, et (2) l’utilisateur de l’appareil doit accepter tout
brouillage radioélectrique subi, même si le brouillage est susceptible d’en compromettre le fonctionnement.
This device complies with the Industry Canada license exempt RSS standard(s). Operation is subject to the following
two conditions: (1) this device may not cause interference, and (2) this device must accept any interference, including
interference that may cause undesired operation of the device.
WARRANTY
What is Covered?
Nortek Security & Control (“NS&C”) warrants to consumers who purchase this product for personal, family or household
purposes new from NS&C directly or from an authorized NS&C dealer, that the product will be free from defects in
materials and workmanship for a period of (1) year from the date of purchase. This warranty only applies if the product is
installed at a residence in the 50 United States or District of Columbia, and only at the site of the original installation. It is
not transferable. This warranty is not extended to resellers.
If a defect exists, NS&C will have you ship the defective part or product to us and we will, at our option, either repair or
replace it. This warranty does not cover the cost of labor to remove a defective part or product or to reinstall any repaired
or replacement part or product
This warranty does not cover defects or damages caused by improper handling, maintenance, storage, installation,
removal or re-installation, misuse, non-factory authorized modification or alteration, use of incompatible accessories,
electrical power problems or surges, impact by foreign objects, accident, fire, acts of God, normal wear and tear or
shipping damage other than a shipment from NS&C. Note that all NS&C products are designed to be installed, removed
and serviced by trained individuals or professionals.
Keep your original sales receipt as it will be required to obtain warranty service.
This warranty shall not be extended or restarted upon receipt of any repaired or replacement part or product under this
warranty. No person is authorized to extend or otherwise modify this warranty.
How do I Obtain Warranty Service?
To obtain warranty service, email our Returns Department at [email protected]. Include your name, address, telephone
number, the model number of your product, a copy of your original sales receipt, and a description of the problem.
Unless we need to discuss the situation further with you, you will be emailed a Return Authorization Number and
shipping instructions. If we need to discuss the situation further with you, we will call or email you. NS&C may require
troubleshooting on installed product before a Return Authorization Number is issued. Anything shipped to us without a
Return Authorization Number will be automatically returned unopened. You are responsible for the charges for shipment
to us, unless you are a California resident.
Limitations
THE DURATION OF ANY IMPLIED WARRANTY, INCLUDING THE WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A
PARTICULAR PURPOSE, SHALL NOT EXCEED THE WARRANTY PERIOD PROVIDED HEREIN.
Some states do not allow limitations on how long an implied warranty lasts, so the above limitation may not apply to you.
NS&C SHALL NOT BE LIABLE FOR ANY INCIDENTAL OR CONSEQUENTIAL DAMAGES RESULTING FROM THE BREACH OF
ANY WRITTEN OR IMPLIED WARRANTY.
Some states do not allow the exclusion or limitation of incidental or consequential damages, so the above limitation or
exclusion may not apply to you.
This warranty gives you specific legal rights, and you may also have other legal rights which vary from State to State.
PRINTER’S INSTRUCTIONS:
INSTR,INSTL,PS15EMZ5-1 P/N 10008371 E, GO CONTROL ; INK: BLACK; MATERIAL: 20# MEAD BOND; SIZE: 8.500” x 11.000”; TOLERANCE ± .125”, SCALE: 1-1 - PAGE 2 OF 2
Copyright © 2018 Nortek Security & Control LLC 10008371 E
This manual suits for next models
1
Popular Accessories manuals by other brands

TC Electronic
TC Electronic Digital Konnekt x32 user manual

aquilar
aquilar AquiTron AT-OPSEN installation instructions

Aromasound
Aromasound LILYCHERRY operating instructions

Lightolier
Lightolier Lytespan 8111 specification

KlikAanKlikUit
KlikAanKlikUit Trust SMART Home ZCT5-808 user manual

molex
molex Advanced Sensor installation guide