NS TOUCH 80 Series User manual

NS TOUCH SWITCHES English
Installation Instruction!
Please read before installing
Electronic Outs
S80 - V08/H08
Series 80
S80 - V06/H06
S80 - 04
S80 - V02/H02
S90 - V08/H08
______________
S90 - 04
S90 - V02/H02
Use these instructions to install models listed above.
NS TOUCH recommends to install touch panels by a qualified electrician.
Do not connect power to the switches output terminals.
Incorrect connection may result in injury, damage of touch switches or any other
equipment.
Use conditions: operating ambient temperature from 5°to 40°C, humidity from 0 to
90%, no condensation. Indoor installation only.
Cleaning: Before cleaning turn off the power of switch! Use special glass washing
liquids, Apply the detergent to a dry cloth or sponge and wipe the surface of the
switch.
Series 85 Series 90
Installation box: to install switches of 80 and 85 series use round electric boxes
Schneider Electric with external diameter external diameter 68 mm.
to install switches of 90 series use GIRA square boxes (instruction for installation is in a
separate file).
Power supply specifications: 12-24 VDC 15 mA.
Specifications of switches outputs/inputs: open collector, voltage 30, maximum
current 50 мА.
open collector
Installation.
Series 90
4 mm
8 mm
Series 80
Series 85
Adapter
Adapter
d = 68 mm
Installation/back box GIRA
Installation/back box
1.
Put the installation box on the wall level exactly vertical. If the back box is installed
by a related contractor, please check the correctness of installation.
S85 - V08/H08
S85 - V06/H06
S85 - 04
S85 - V02/H02
Storage conditions: temperature: from - 30 to +70°С, humidity from 0 to 80%, no
condensation.
S80 - 01 S85 - 01 S90 - 01

2.
Set adapter into the installation box exactly vertical.
Tighten the screws until their surface is equal with the adapter surface.
After connecting the cable, insert the panel vertically into the adapter, press down
with your palm or two thumbs on switcher surface and snap it.
3.
а. The first position in which you will feel the
connection of the case and adapter.
b. Press down evenly on the panel and
click into place.
Note: In case the back box is not installed vertically,
rotate the adapter and set it straight. Possible tilt angle
of the adapter 15 degrees.
Adapter
Use the screws supplied with
the switch.
Adapter installation. Installation of the switch.
.

UP
UP
DC 12-24V
2
1
3
4
5
6
Outputs of
keys
7
8
9
10
UTP cable
CAT5E, CAT6E
5.
Connect a switch. The purpose of the terminals is presented in the table 1. Connect UTP
cable starting with terminal 1 and so on, the last connect a switch power terminals 9 and
10.
Purpose of connectors.
1
Output of 1 key
2
Output of 2 key
3
Output of 3 key
4
Output of 4 key
5
Output of 5 key
6
Output of 6 key
7
Thermistor (Option*)
8
Thermistor (Option*)
9
GND
10
+12 - 24 VDC
Table 1.
4.
Correspondence of keys and exits. Exit numbers 1 - 6 correspond to the keys of the
switches, as shown in the figures.
* Note: 8 sensors switch consists of 2 independent 4 sensors switches.
1 sensor
1
2 horizontal
sensors
1
2
4 sensors
1
2
3
4
8 vertical
sensors*
1
2
3
4
5
6
7
8
1
2
2 vertical
sensors
8 horizontal sensors*
1
2
3
4
5
6
7
8
Numbering of sensors of exits OUTs.

UP
UP
Recommended parameters are set up on commutator by default. Operating mode
"Impulse", Sensibility of keys «High", click – «On», level of finish backlight of icons -
"Minimal".
ON
DIP
1 2 3 4 5 6 7
DIP
Operating modes
1
2
OFF
OFF
Impulse
OFF
ON
Active
ON
OFF
Only one
ON
ON
DIP
Initial backlight
6
7
OFF
OFF
Off
OFF
ON
Minimal
ON
OFF
Optimal
ON
ON
Maximal
Operating modes
Only one. Available for 2, 4, 6 keys. After press of the key the output remains active
for 60 seconds, then turns off. If another key is pressed before the end of this time,
output of the first key turns off, output of the second one remains active for 60
seconds. Thus, only one output can be active at a time.
Recommended parameters
DIP commutator parameters.6.
Impulse. In this mode, the key outputs work like a pulse switch. So far, the finger on
the key - the output is active. Backlight and click in this time work cyclically with step
0.75 sec. Maximum number of cycles per press - 30.
Active. After press of the key output and backlight become active till the next press.
All outputs may be active in the same time.
Sensors sensibility. Then higher the sensibility level, then less the touch area needed
for key reaction.
DIP
Sensor sensitivity
3
4
OFF
OFF
Low
OFF
ON
Medium
ON
OFF
High
ON
ON
Very high
Touch clicking. In OFF position clicking is switched off. In ON position clicking is
switched on.
DIP
Touch clicking
5
OFF
Off
ON
On
Initial backlight. Level of icons backlight in rest mode.

Vendercode. Example 2 key switch of 85 series and 3 posts combo.
8.
Incrustation
AL = aluminum
BR = brass
Series
80, 85, 90
Product surface
7 = gloss
3 = matte
Interface
0 = Electronic Outs
2 = Electronic Outs/Inps
Location of sensors
V = vertical
H = horizontal
-
S85
V02
-
DE
BR
3
S = stone
W = wood
H = hpl
Number of sensors
1,2,4,6,8 = сенсорів
Stone color
DW = Designer White
WO = White Onyx
RC = Rain Cloud
AI = Arctic Ice
GO = Gray Onyx
AG = Athena Gray
CC = Carbon Concrete
CA = Carbon Aggregate
EP = Evening Prima
DT = Deep Titanium
DE = Deep Espresso
DN = Deep Nocturne
-
Combo 3HS90
H02
GO
AL
CH2ac
R1
-
7
Location of combo
V = вертикальная
H = горизонтальная
Number of posts
2,3,4,5 = поста
Premium Design
Premium Technologies
/90/
** Sockets can be created with the same design as switches of each series and can be equipped with JUNG and GIRA mechanisms.
*may also be located horizontally
S90-0810G/V
161x90x4mm
R90-02
R90-04
R90-03
161x90x8mm
303x90x4mm
232x90x4mm
-
SL
Socket color
WG = White gloss
BG = Black gloss
SL = Silver
CH = Champagne
MO = Mocco
WM = White matte
BM = Black matte
AM = Anthracite matte
Material
7. Example of connection.
Consider an example of connecting a device RSi8 and NS TOUCH switch.
Connect bouth devices to the one power unit, combining their minus. Then connect
outputs of the switch to the discrete inputs of the relay station.
Note that the connection of two or more keys of different switches to the input of the
station is carried out in parallel.

Opening the switch housing voids the warranty. Before connecting the switch, make
sure that all wires connected to it are de-energized!
Do not apply voltage to the discrete input terminals of the switch. Failure to follow
the instructions in this manual may result in damage to the switch, other equipment,
or other hazards. In this case, the manufacturer disclaims all liability for damage to
people and property (direct, indirect and any other).
Warranty obligations9.
The manufacturer guarantees the normal operation of the product for 24 months from the
date of purchase of the device from the dealer, provided that the Buyer complies with the
operating conditions.
The manufacturer's warranty obligations apply only to damage to the device caused by
defects in the manufacture of both the product itself and the components used. If during
the warranty period the manufacturer receives a notification of the presence of such
defects, he may perform repairs or replace it at its discretion.
The manufacturer provides a limited warranty on the firmware. This warranty does not
apply to defects due to improper use, any modifications made by the user, opening of the
device (absence or a damaged warranty seal on the device housing), repair by
unauthorized specialist, use of the device or its storage outside the permissible limits of
temperature, humidity, pressure, software modifications made by the user, as well as the
following cases:
- The device has failed due to a problem in the public power supply network (voltage
fluctuations and surges, overload, etc.);
- The device has failed due to the ingress of liquid;
- The device has failed due to extreme temperatures;
- The device has failed due to a natural disaster or natural phenomenon (lightning strikes,
forest fires, floods, etc.);
- The device has failed due to mechanical damage (falling from a height, etc.);
- The device has failed due to the connection of a power supply with an invalid output
voltage or a faulty power supply;
- Inside the body of the device are founded extraneous objects, insects and more;
- Physical tampering with the device - opening the device, absence of warranty seals.
The information contained in this document is subject to change by the manufacturer
without notice. Although every effort has been made to ensure that the information
contained in this document is accurate and free from errors and typographical errors, the
manufacturer assumes no responsibility for their possible existence or for any
consequences to which may be caused by errors in this document.
The manufacturer is not responsible for the illegal use of this device and for the fact that
this manual, hardware and software supplied do not meet the expectations of the user
and his opinion on where and how to use the above. All copyrights for the supplied
equipment described in this manual, the software installed in the equipment and (or)
supplied with it, and the manual itself belong to the company“NS TOUCH LLC”.
Copying, reproduction, translation into other languages of this manual is not allowed.
Copying, duplication, modification, disassembly of software and / or device is not
allowed.

Manufacturer:
NS TOUCH LLC
Contact our official distributor in Ukraine for purchasing and support:
Smarttech Group LLC
Phone: +393703382554
NOTES
ns-touch.com
This manual suits for next models
24
Table of contents