9
Installation
F) Positioning, installation and connection
F.1) Position and connection of floor sensor
Position of oor sensor in the room.
Position the oor sensor about 0.5 m from the wall.
Position the oor sensor near the HC10B. This gives the simplest installation.
If desired, the oor sensor cable can be extended.
Optional extension of oor sensor cable
Use ordinary doorbell cable to extend the oor sensor cable. Maximum extension 9m.
Position of oor sensor in oor.
Position the oor sensor in a pipe approximately half-way between two heating
cables.
If necessary, the sensor may be placed in a grouting gap, without the use of a pipe.
Note: When positioning in a grouting gap, any regrouting should be undertaken with
care in order not to damage the sensor.
Connection of oor sensor.
Connect the oor sensor to the HC10B as shown on the diagram.
F.2) Position and mounting of HC10B
Important! HC10B must not be covered.
PIf the oor sensor (FL) is used, any position may be used.
PIf the room sensor (RO) or combined room and oor sensor (CO) are used,
HC10B must be positioned approximately 1.2 m above the oor.
Avoid:
PHeat from radiators, wood-burning stoves and other heaters
PCold outer walls
PConcealed pipes or chimneys which give off heat
PDirect sunlight or positioning behind curtains
Installation can be carried out in two different ways:
PFlush-mounted in the wall
PSurface-mounted on the wall
Selection of installation box for ush mounting
For walls of wood, plasterboard etc, use ush-mounting box (53000003)
For walls of brick, concrete etc. use ush-mounting box (53000002)
Selection of installation box for surface mounting
When mounting on the surface of a wall, use surface-mounting box (53000001).
Installation and connection of HC10B
Remove the front cover from the display by inserting a small screwdriver in the
square hole on top of the thermostat. At the same time, carefully lift the front cover
outwards. Then remove the frame.
Connect wires and sensors to HC10B in accordance with the diagram.
Connection must be made by an authorised electrician.
Important! See section, Starting up underoor heating with HC10B, before turning
on the power.
Replace the frame and press on the cover. Activate the lock with a click.