LCD
Instructions
1. Press the “FUNCTION” button to view the detection results, the pages
are displayed as follows:
1 Time display bar;
2 V / A / W / KWh value;
3 POWER FACTOR / HZ / COST / KWh value;
4 V: Voltage;
A: Current;
(KWh) kilowatt hour: Electricity consumption;
W: Power;
OVERLOAD: Power overload reminder
5 POWER FACTOR: Active power and apparent
power ratio;
HZ: AC Frequency;
DAY: Cumulative electricity consumption days;
COST: Cumulative amounts of electricity
consumption;
KWh: Cumulative Electricity consumption;
COST/KWh: Unit price of electricity.
Page 1:
1 Running time: Cumulative running time of
electrical appliances.
Below 1 hour: min. : sec. / above 1 hour: h : min.
After 24 hours: DAY+ 1;
2 Current Power: The actual power of the
electrical appliance connected to it, Unit: W;
3 Cumulative electricity bill - costs consumed to
date, Unit: Cost.
Page 2:
1 Running time
2 Cumulative electricity consumption:
Cumulative electricity consumption up to now,
Unit is KWh;
3 Accumulated time: the cumulative number of
days the appliance has been running,
Unit: DAY.
Page 3:
1 Running time
2 Grid Voltage: current real-time voltage
of the grid, Unit: V;
3 Grid frequency: Grid AC frequency, Unit: Hz.
Page 4:
1 Running time
2 Real-time current: the real-time current of the
lectrical appliance connected to it, Unit A;
3 Power Factor: the power factor of the Electrical
appliance connected to it.
Page 5:
1 Running time
2 Minimum power: the minimum value of power
recorded during the operation, Unit: W
3 Lo: Symbol, meaning “Low”
Page 6:
1 Running time
2 Maximum power: the maximum value of power
recorded during the operation, Unit: W
3 Symbol, meaning “High”
Page 7:
1 Running time
2 Empty display
3 Unit price of electricity: set unit price,
Unit COST/KWh
Unit price quick view
Press the "COST" button to check the current unit price of electricity bill
Unit price setting
Long press "COST" button to enter unit price setting,
Press the "FUNCTION" key to select the setting position,
Press "UP key" or "DOWN key" to adjust the value,
Press the "COST" key to confirm and exit the setting.