NTS
Narzędzia i Technika Serwisowa
NTS Sp. z o.o. tel.: +22 7520600
Sales Office: fax: +22 7520592
ul. Warszawska 749 www.nts.com.pl
Borzęcin DuŜy e-mail: nts@nts.com.pl
05-083 Zaborów
5. DESCRIPTION
5.1 Correct use
5.1.1 The pumping of chemical bonding products (silicone-polyurethane-cement-adhesives-etc.) provided in special
containers, 310ml aluminium or plastic cartouches, and 400ml sachets.
5.1.2 Always work in conditions suitable for certain products.
5.2 Wrong use
5.2.1 The pumping of any other products than those listed in item 5.1.1 above.
5.2.2 Any other use than specified in item 5.1.1 above.
Use the product MSDS to verify if it really matches your equipment, operating conditions, and that the personal protective
equipment used by the operator is suitable for the treated material.
Wile using the spray gun, hold it a minimum of 30 cm away from your face when you release the trigger because
compressed air escaping from the discharge valve may seriously harm your face (eyes, ears, etc.).
5.2.3 Use of loose products.
5.2.4 Use of the spray gun without complete sealing of the front nut (2).
6. NOISE LEVEL
When trigger (3) is released, the acoustic pressure level corresponds to scale a, measured horizontally at a distance of
50 cm while gluing.
7. SPRAY GUN OPERATION
7.1 Air flow and product pumping is possible when the following conditions are met:
The main pressure reducing valve and supply valve are open (fig. 2).
The air gun pressure regulator is open (fig. 1, par. 5).
The release trigger (3) is operated manually.
7.2 Sachet loading (into pumping chamber) - see par. 4.2.
7.3 Cartouche loading (into pumping chamber) - see par. 4.3.
7.4 Packaging removal and loading - see par. 4.4.
7.5 Compressed air connection - see par. 4.1.
7.6 Always cut off the pressure supply after finishing working with the spray gun. If the cartouche or sachet are not
empty yet, close them tightly to ensure that they may be reused later.
8. ADJUSTMENT OF OPERATING PARAMETERS
In order to adjust the pressure with the pressure regulator (fig. 1, par. 5), pull out theplastic knob and turn it anticlockwise
to obtain a gradual increase of pressure and force, with which the product is being pumped. As soon as the parameters
are set, we recommend to push the knob back to block it.
Never exceed maximum allowable pressure (10 bar).
Read the product instructions for use and check the minimum working temperature.
9. IGNITION HAZARD
A fire hazard may occur depending on the type of product being used. It is prohibited to smoke and use open fire during
work with the spray gun.
10. IF YOU HAVE PROBLEMS WITH THE EQUIPMENT
The product does not come out of
the spray gun when you release the
trigger (fig. 3, par. 1).
No compressed air supply.
Check the supply hoses. Open the pressure regulator (see
par. 8 - adjustment of pressure parameters).
Poor and irregular product outflow.
The product is too thick, or pressure
is too low.
Adjust the pressure using the regulator (fig. 1, par. 5).
Increase the pressure if needed. Check if the product and
working temperature are suitable.
The pumping chamber is soiled
after finishing work.
The container has been opened
incorrectly or damaged.
Carefully clean all elements and replace the container. Cut
off the sachet end immediately after the closing metal tape
(see par. 4.2 - sachet insertion).