No Bubbles from Diffuser
If bubbles do not come out of diffuser, try these steps:
• Make sure that the indicator LED is blinking. If the light is “ON,” but not blinking, the
unit is in standby. Wait for 10 minutes for another ozone cycle to occur.
• Clean the diffuser (see servicing for details)
• Confirm compressor is energized during an ozone cycle
• Check all tubing and fitting connections for possible leaks
• Confirm wired connection between compressor and control board is seated correctly
Service Run Time Indicator
Solid red light means service is required
When the unit has reached approximately 9,000 hours of runtime, a solid RED
service light should appear and remain on until service has been performed.
• Service light appears at 9,000 hours
• Service light will not stop ozone production
• Service light must be manually reset by user
Power Light Does Not Illuminate
If power indicator light does not illuminate on right side of unit, try these steps:
• Verify the unit has power
• Press the Mode Select button to see if the unit will cycle through different modes
• Unplug the unit, remove cover and confirm that the main power wires at the
control board are seated securely. If the connection is loose, disconnect the
wires fully and reseat the connection.
NOTE: Service will be required at 9,000 hours of runtime
NOTE: If no bubbles, wait 10 minutes for next ozone cycle
NOTE: Confirm power if no lights are present