NuTech 3000 User manual

Nutech 3000 Portable
THC & NMHC Analyzer
The Latest Generation of Portable
VOCs Analyzer for Stationary
Emission Source & Fence Line

VOCs Analysis Methods
VOCs Analysis
Lab Online Portable
VOCs can be analyzed by lab instruments, online instruments and portable instruments. Nutech
is the only company who can provide VOCs analysis solutions & products for lab, online and
portable applications.
Nutech 3000 Portable THC & NMHC Analyzer is the latest generation product for portable VOCs
analysis and we’ve made many improvements based on the existing products on the market.
The Necessity for a Portable VOC Analyzer
⚫The gas sample at emission source is hot and moisture. It is evitable to cause sample loss,
adsorption and deterioration during sample collection and transportation for lab analysis
and thus the test results will be affected.
⚫Lab analysis can’t deliver timely results and thus its is not applicable for emergency
monitoring.
⚫The lab analysis is labor intensive with samples to be collected, transported and analyzed.
⚫Online analyzers are permanently installed and need regular maintenance which doesn’t fit
for applications that only require occasional / periodical / emergency monitoring.
Occasional Monitoring Periodical Monitoring Emergency Monitoring

Why List NMHC as an Monitoring Target
•TVOC can be represented by THC (CH4+NMHC) or NMHC.
•CH4 is a non-toxic and unharmful gas and it accounts for the major part of THC. NMHC is the
harmful & hazardous part in THC. Thus, to analyze toxic VOCs, NMHC is a more precise target
than THC.
TVOC THC
CH4
NMHC
NMHC is a more precise representation of TVOC
Typical Applications
•Environmental inspection and law enforcement by government regulator
•VOCs testing by commercial testing companies
•Effectiveness evaluation of VOCs control measures
•Self-inspection of VOCs emissions from chemical, printing and dyeing, spray painting
companies
•On-site detection and supervision of kitchen oil fume
•On-site comparison with the results of online VOCs analyzer to determine whether the online
analyzer’s result is accurate.
•VOCs emission detection of combustion device exhaust

⚫Government environment protection regulators. They can bring this instrument to raid a
suspected over-emission site and do test on-site to see if there is an over-emission. If yes, they
can fine the owner. They can also use this instrument to do a before and after comparison to
evaluate the effectiveness of their VOC control measures .
⚫Polluters/factories. Some polluters are required to install online analyzers to deliver
continuous real-time test results all year long. But many polluters only need to perform
periodical (weekly, monthly, quarterly ect) or occasional VOC testing. In this situation, a
portable analyzer would be more applicable than an online analyzer.
⚫Commercial testing companies. They can use the portable VOCs analyzer to provide on-site
VOCs testing service.
⚫Research institutes. They can use this instrument on their VOCs research projects.
Typical Users
Technology Principle
TVOC can be represented by THC or NMHC. The Nutech 3000 adopts catalytic oxidation + double
FIDs technology to simultaneously analyzes THC & NMHC.
The sample gas is introduced to the analyzer by 2 channels. FID 1 analyzes the concentration of
THC (total hydrocarbon) of the gas sample in channel 1. And the catalytic oxidation module
oxidizes the NMHC (non-methane hydrocarbon) into CO2 and H2O in channel 2 and thus FID 2
only analyzes the concentration of methane. The concentration of NMHC can be calculated by
concentration of THC subtracts the concentration of methane.
Concentration of NMHC = Concentration of THC –Concentration of CH4
Analyzed by FID 1 Analyzed by FID 2

•Detection Method: Catalytic Oxidation + Double FID
•Measuring Range: 0~10/100/1000/10000 ppm (Automatic)
•Detection Limit: ≤50ppb (Calculated by Carbon)
•Zero Drift: ≤±1% Full Scale/8H
•Span Drift: ≤±1% Full Scale/8H
•Repeatability: ≤±0.1% Full Scale
•Indication Error: ≤±1% Full Scale
•Conversion Efficiency: ≥95%
•Warm-up Time ≤30min
•Data Resolution (T90): THC≤2s; NMHC≤2s
•Working Environment: temperature: -20 ℃~50 ℃; relative humidity: <95%; atmospheric
pressure: (80~106) kPa
•Power Supply: DC24V, AC (100-240±10%) V/(50±2%) Hz
•Dimensions: 370x260x397mm
•Weight: <12KG
Technical Data
Standard Configuration
Instrument main unit (including catalytic module, metal hydride cylinder), sampling tube
(including probe, filter device), Microsoft Surface GO tablet, backpack.
Lightweight & Integrated Design
•Highly integrated design to ensure the total weight within 12KG (including catalytic module,
metal hydride cylinder, battery, zero air generators, etc)
•Analyze THC & NMHC in one single unit.
•Equipped with a backpack and a handle, which can be easily transported and put into use by
one person.
Easy to Use
•Large-capacity battery (45Ah) power supply, which can run for a long time even without
utility power on site.
•Operated by a detachable touch screen tablet with Wi-Fi communication and a user-friendly
interface. Users can control the instrument and read test results within 50m (33ft) of the
site through the detachable tablet.
Features

High Test Efficiency
•New catalyst is used to achieve high conversion efficiency (≥95%)
•Double FID design and can measure both THC & NMHC continuously at the same time
without the need to switch gas flow. It can deliver NMHC test results as fast as every second.
•Fast gas path cleaning speed.
Most Accurate Test Result
•From the sampling tube to the FID detector, the whole process is high temperature heating
to avoid condensation loss of high temperature and high humidity gas samples.
•The sampling flow path is silanized (a special surface treatment technology to make the
surface utmost inert), resistant to high temperature and corrosion, and contains a filter
device to effectively filter particles to avoid sample contamination and adsorption.
•High precision EPC and FID are adopted to ensure accurate flow control and accurate
measurement.
•Support automatic & manual purge function to keep the system clean and thus deliver more
accurate test results.
Powerful & Easy Data Processing
•Data file automatic recording and storage, historical data query, reprocessing and printing
functions.
•Test data can be exported in Excel file.
Lowest Running Cost in Its Kind
•H2 is supplied by mini built-in metal hydride cylinder with very low pressure and thus is safe
and easy to handle and transport. The metal hydride cylinder is recyclable.
•Zero air is supplied by internal pump. No need disposable zero air bottle.
•Also support external gas cylinder
Wide Applications
•Applicable in VOCs measurement in stack (high concentration), inside the factory (medium
concentration), outside the factory/fence line (low concentration).

Version: 202008EN
User Manual
Nutech 3000
Analyzer for THC & NMHC

2
Notice
Thanks for choosing our products. Please read this manual carefully before using the product to
ensure the safe and correct use of the product and to obtain a good application experience.
Unless otherwise specified, this manual is only applicable to Nutech 3000 analyzer for THC & NMHC.
Due to product technology updates, Nutech reserves the right to change the product pictures and
texts listed in this manual without prior notice.
If you have any questions, please contact Nutech or Nutech’s authorized partner in your country
or region.

3
Content
SAFETY NOTICE................................................................................................................................................4
SAFETY PRECAUTIONS....................................................................................................................................4
INSTRUMENT INTRODUCTION ......................................................................................................................6
USER NOTICE ...................................................................................................................................................7
WARRANTY AND LIABILITY ............................................................................................................................7
TRANSPORT AND STORAGE ...........................................................................................................................8
DELIVERY CHECKLIST ......................................................................................................................................8
INTRODUCTION OF INSTRUMENT COMPONENTS.......................................................................................9
INSTALLATION AND COMMISSIONING ...................................................................................................... 10
METAL HYDRIDE HYDROGEN CYLINDER USAGE INTRODUCTION ........................................................... 11
INSTRUMENT FUNCTIONS .......................................................................................................................... 12
SIMPLE OPERATION PROCESS..................................................................................................................... 21
MAINTENANCE & TROUBLESHOOTING ..................................................................................................... 21
ACCESSORIES & CONSUMABLES................................................................................................................. 22
FEATURES & TECHNICAL DATA.................................................................................................................... 22

4
Safety Notice
The information identified by this symbol is essential to the health and safety
of the operator. Actions that violate this symbol may cause harm to your
health or personal safety.
The information identified by this symbol is very important to ensure the
normal operation of the instrument. Operators who violate this symbol may
cause damage to the instrument.
The information identified by this symbol is very important to ensure the
effective operation and use of the instrument. Operators who violate this
symbol may cause inaccurate results.
Safety Precautions
Before operating the instrument, please read the instructions carefully and follow the safe
operation norms.
Please keep the instructions carefully for future reference.
Please ensure that only personnel with relevant training can operate and use this instrument.
Please abide by relevant regulations such as safety regulations.
Electricity Safety
Make sure that the power supply socket and the power cable plug of the instrument match each
other.
Check the voltage of the power supply socket and confirm that the power
supply voltage is 220V/2V AC (110V/2V AC). Confirm the phase, neutral and
ground wires are connected correctly and the grounding is good.
In order to avoid the risk of electric shock and damage to the instrument,
disconnect the power supply before disassembling the instrument. It is
forbidden to disassemble or plug the internal cable plug of the instrument
while it is live. Without professional guidance, non-professional is not recommended to
disassemble the instrument.
This product includes a lithium battery module. Although the corresponding protection treatment
CAUTION
WARNING
DANGER
DANGER
WARNING

5
has been carried out in accordance with IEC62133-2012 during the design and manufacturing
process, users are obligated to comply with the relevant regulations for the transportation and safe
use of lithium batteries in their country or region.
Please use the original AC adapter to avoid overheating or other problems
that may be caused by using adapters with different specifications
Do not charge in direct sunlight or other high-temperature environments
(60°C) to avoid accidents; Prevent possible circuit breakage when charging
the battery and avoid applying abnormal current or voltage during charging,
otherwise it may cause overheating, explosion or fire.
If the battery exhibits peculiar smell, overheating, change of color or other
abnormalities during use, charging or storage, please stop using it
immediately. Continued use of such batteries may cause overheating,
explosion or fire.
Gas Safety
Gas cylinders must be handled, stored and used in accordance with the relevant safety regulations.
The marking of the gas cylinder should be clear.
Cylinders should be stored in a well-ventilated area, away from heat sources,
and should be securely fastened to ensure safety.
Gas cylinders, single-stage pressure regulators, gas pipelines and joints must
not leak.
Hydrogen is also used during the operation of this product. The protective measure adopted during
the design and manufacture of the product cannot replace the user's obligation to comply with the
relevant regulations about hydrogen safety in their countries or regions.
The gas line should be connected correctly. Do not connect the hydrogen
gas line to the air inlet of the instrument, otherwise the hydrogen gas will
leak out in large quantities and cause danger.
The valve of the hydrogen source (cylinder or generator) must be closed
when the instrument is not in use, and it must always be ensured that there
is no leakage from the hydrogen source itself.
DANGER
DANGER
WARNING
DANGER
DANGER
CAUTION
CAUTION
DANGER

6
To prevent explosion accidents caused by hydrogen leakage, the room where
the instrument is placed must be well ventilated and comply with the fire
protection regulations.
Shutdown Steps in Emergency
When there is an emergency and need to shut down immediately, please follow the steps below:
1. Turn off the power switch of the main unit.
2. Turn off the power switches of all auxiliary equipment.
3. Close the valve of all gas sources.
4. Unplug the power plug of the instrument.
Instrument Introduction
The Nutech 3000 is an instrument for portable monitoring of total hydrocarbons, methane and
non-methane hydrocarbons in stationary emission sources. The instrument is controlled by
computer software and communicated through WiFi connection.
It is appliable in:
⚫Environmental inspection and law enforcement in stationary emission source and fence line
(perimeter of industrial site)
⚫Non-methane hydrocarbon testing by third-party testing companies
⚫Effectiveness evaluation of VOCs control measures
⚫Self-inspection of VOCs emissions from chemical, printing and dyeing, spray painting
companies
⚫On-site detection and supervision of kitchen oil fume
⚫On-site comparison and acceptance of the automatic monitoring system for VOCs
⚫VOCs emission detection of combustion device exhaust
To adapt to various experimental requirements, please use Nutech original
consumables and accessories.
CAUTION
DANGER

7
User Notice
This chapter describes how to use the manual more effectively so that you can operate the
instrument more safely and reliably.
Be sure to comply with the provisions in the Safety Precautions chapter.
The content of the chapter Transport and Storage is related to the reliability of the instrument.
Only correct operation can guarantee the accuracy of the measurement and the service life of the
instrument.
The chapter Introduction of Instrument Components describe the hardware components for easy
identification.
Please note that the operation steps indicated in the following chapters of
this manual must be carried out as specified.
Warranty and Liability
According to the Nutech’s warranty, this instrument is guaranteed for 1 year. If there are any
problems during the warranty period, please contact your supplier. You may also send the
instrument directly to us with an invoice and problem descriptions and the freight is borne by you.
The warranty does not cover natural wear and tear of parts and does not apply to damage caused
by negligence, improper handling or failure to use and maintain the product in accordance with
the operating instructions.
Please read these instructions carefully. Nutech is only responsible for the safety, reliability and
performance of the instrument under the following conditions:
⚫Operate in strict accordance with the instruction
⚫Only our authorized personnel will perform maintenance on the instrument.
⚫Use only original parts and accessories for repairs
The Nutech 3000 can only be opened by authorized maintenance facility or customer service
center personnel. If maintenance is required, please contact Nutech’s Customer Service
Department. In addition, please comply with the safety regulations and accident prevention
guidelines for the operation of the instrument. Nutech cannot be held responsible for damage
CAUTION

8
caused by accident, improper use or illegal modifications or maintenance.
Transport and Storage
Transport and Storage Requirements
During transport and storage, it must be ensured that the instrument is not subjected to
considerable vibration, crushing, dust or corrosive gases. The ambient humidity should not exceed
80%. Clean it properly first before transporting or storing.
If you need to return to the supplier for repair service, please clean the instrument and make sure
that it is free of any materials that are harmful to human health. Send the instrument back properly
packed in its original box. If the original packaging does not exist, please use other suitable
packaging (please contact Nutech for details).
Unpack
Please carefully unpack and inspect the instrument. When unpacking the instrument, check the
instrument to see if there are damages caused by transportation.
If any damage is found, please fill in the damage report and notify the shipping company
immediately.
Delivery Checklist
The standard configuration contains:
Item Number
Item Name
Quantity
1
Nutech 3000
1
2
Custom backpack
1
3
Instrument power adapter
1
4
Hydrogen cylinder
1
5
Sampling extension tube
1
6
Sample filter
1
7
USB Disk (User Manual, Control Software)
1
8
Certificate of conformity
1
9
7/16 wrench
1
10
9/16 wrench
1
11
Tablet computer
1
12
Tablet power adapter
1

9
Introduction of Instrument Components
A
Logo
B
Power button
C
Tablet computer
D
Tablet computer holder
E
Handle
F
Sample extension tube
G
Hydrogen cylinder switch knob
H
Hydrogen inlet
I
External cylinder air inlet
J
Standard gas inlet
K
Sample filter device
M
heating tube
L
Power jack

10
Installation and Commissioning
Please read the relevant operating instructions carefully. Nutech will be responsible for the safety,
reliability and performance of the instrument only if the following tasks are done:
⚫Operate the instrument according to the instructions
⚫The operating place and hardware requirements are met
Operating Place
Environment Requirements
⚫No direct sunlight
⚫The instrument should be kept away from heat sources
⚫Keep away from areas with strong wind
⚫Avoid direct rain
Space Requirements
⚫Size: 370x260x397mm
⚫Weight:around 12KG according to configurations
Power Supply Requirements
Power supply voltage: 220V ± 10%; or 110V ± 10%.
Gas Requirements
H2: combustion gas, purity> 99.999%; input pressure: 100psi.
Air: Built-in air pump (default) or external air cylinder
Note: If there is no cylinder gas on site, a gas generator can be used.
Hardware Requirement
Connection Tube

11
⚫2 to 3 meters of 1/8" clean Teflon tube or copper tube for air source
⚫0.5 to 1 meter of 1/16" clean silanized tube for standard gas
Connector
Inlet
Connector Specifications
H2
1/8″ Swagelok connector
AIR
1/8″ Swagelok connector
Standard
1/8″ Swagelok connector
Other Requirements
⚫Standard gas for calibration: methane standard gas with known concentration, inlet pressure
4-10psi
⚫Standard gas for quality assurance: propane standard gas with known concentration, inlet
pressure 4-10psi
Air Line Connection
AIR: The high-pressure cylinder is connected to it by a pressure reducing valve or by using a zero
air generator or by using the built-in air pump.
H2: The high-pressure gas cylinder is connected to it via a pressure reducing valve or by using a
metal hydrogen storage cylinder.
Sample: 1/4″ Inlet tube and filter.
Standard: A 1/16″ silanized tube is recommended for connection.
Metal Hydride Hydrogen Cylinder Usage Introduction

12
Filling Hydrogen into Metal Hydride H2 Cylinder
1. Put the metal hydride hydrogen cylinder in ice water and connect it with the hydrogen tank.
2. Set the output pressure of the hydrogen tank to be 0.6Mpa.
3. Open the valve to introduce hydrogen into the metal hydride hydrogen cylinder. The cylinder
will become hot shortly. The H2 filling process will compete in about 1 hour.
Instrument Functions
Start the Instrument
1. Open the hydrogen cylinder and press the "Power" switch of the instrument
2. Turn on the tablet and enter into below interface. The software has self-started function and
connects with the instruments automatically.
0.6Mpa

13
3. When the instrument is turned on, it will automatically ignite. Wait for the device status to be
idle which signify that the device is successfully warmed up.
When the small circle of hydrogen status is red, it means that the pressure
of the hydrogen cylinder is insufficient. It needs to be filled with hydrogen
before use.
Parameters Setting
Click the Setting button on the left side of the software interface to enter the parameters setting
interface as shown in the figure below. The gases flow rate parameters on this interface are factory
settings and cannot be changed. After the setting is completed, click "OK" to complete the setting.
CAUTION

14
Sampling Mode
1. Single
Click the small circle on the left of Single to select this mode. After setting the sampling time and
cleaning time, the instrument will only take in one sample and analyze the data once.
2. Multiple
Table of contents
Other NuTech Measuring Instrument manuals