NVR SYSTEMS DZE2 User manual

DZE2
DC Servo Barrier Gate
Manual
N o.2 0 1 9 .3
DZE2
Pictures for reference only, the product
prevails in kind
Servo Barrier Cont rol ler
Warning: When power oFF, there is still high voltage inside the control
board before the indicator light goes out. So please do not touch the
circuit inside or spare parts unless you are professional!

Contents
1. Brief Introduction...............................................................1
2. Functions and Features........................................................1
3. Technical Data....................................................................1
4. Mechanism Structure..................................................................2
5. Installation Direction Definition...........................................2
6. Mechanical Part Installation and Adjustment..............................3
6.1. Cabinet Installation.............................................................3
6.2. Spring Selection, Installation and Adjustment.......................3
6.3. Mechanism Installation Direction Change ............................4
7. Controller Explanations and Instructions .................................... 6
7.1. Controller Interface Explanations......................................... 7
7.2. Controller Auto-Detect after Power-On Description............... 8
8. Common Malfunctions and Solutions.......................................... 9
9. Warranty and Service Items.........................................................9
10. Maintenance...........................................................................10
11. Packing List............................................................................10
I. Spring Selection Table...............................................................11
II. Remote Control Coding............................................................12
III. Wiring Diagram for R&G Light Interface..................................13
IV. Drive Requirement for Main Control Board Wire Control......13
1. It is forbidden to open the barrier cabinet top cover or door when it
is working.
2. There must be a grounding connection for the barrier cabinet.
3. Make sure there is no person or any obstruction under the boom
when it is falling.
4. Before delivery, the barrier gate spring and the boom length are
well-balanced. It is not allowed to change the boom length randomly.
If needed, please check with the technician.
Warning!
For safety, please do follow the instruction strictly to manage this
product:
This is our newly-produced DC servo barrier gate, which utilizes
the updated electronic control technology and machinery processing
technology, no limit switch design, to realize non-adjust of
mechanism, adjustable speed, automatic speed reduction, ext. In
this way, make the barrier operate more steadily and more reliably.
This product is highlighted in frequency applications and longer
lifetime.
2.1. No clutch design: open the barrier gate by manual hand wheel
when power of.
2.2. No limit switch design: the motor can detect the boom position
automatically.
2.3. Bi-direction boom holder design: left-installation and right-
installation can be exchanged easily and quickly.
2.4. Self-detect after power-on, open/close speed is adjustable.
2.5. With auto-reversing on obstruction function.
2.6. Infrared photocell interface is available. (need to install
photocell device).
2.7. Loop detector interface is available, to avoid hitting the vehicle,
and control the boom falling down automatically after vehicle
passing. (need to install loop detector)
2.8. Built-in delay auto-closing function, coordinated with counting
function, if the numbers of vehicle passed less than the stored
numbers, the boom will fall down automatically by countdown, but
will be new countdown if there is up or loop detector signal.
2.9. With auto-aging test function.
2.10. NO/NC wire control signal input are optional.
3.1. Working temperature (motor): -35°C~ + 85°C
3.2. Working Power: 220V±10%, 110V ±10%
3.3. Motor Power: 120W MAX
3.4. Humidity: 90% RH
3.5. Distance of remote control: L≥30M
3.6. Insulation Grade: F
2. Functions and Features
3. Technical Data
1. Brief Introduction
1
. .
Appendix

4. Mechanism Structure
5. Installation Direction Definition
(Figure 2)
When placing the order, please confirm “left-installed” or “right-
installed”. Figures as below:
6. Mechanical Part Installation and Adjustment
6.1. Installation of cabinet
Please select the correct type of barrier gate according to the
specifications of the place, and then fix the barrier cabinet with
expansion bolts. (refer to Figure 3)
6.2. Spring selection, installation and adjustment
The barrier gate is well-adjusted before delivery. If need cut off the
boom, please re-set the menu “ Boom Length Selection” in the control
unit to ensure the smooth operation of the barrier.
6.2.1. Spring selection
The length of spring prevails in kind, designing change without notice.
The spring selection please refer to the spring selection table in the
Appendix I of the Manual or which sticks on the door of the barrier
cabinet.
6.2.2. Spring installation, disassembly and replacement
Dismantlement steps: Keep the boom at vertical position, see figure 1,
loosen the spring fastening nuts, unscrew the M8*140 spring adjusting
screws by a hexagonal spanner, then take off the spring.The steps for
installation and disassembly the spring are the opposite.
6.2.3. Spring force adjustment
When power oFF, please turn the motor hand wheel to make the boom
move towards the closing direction, when the boom gets close to the
horizontal position, if the hand wheel can not be turned smoothly,
which means that the spring force is small, users need to tighten the
spring; and then please turn the motor hand wheel to make the boom
move towards the opening direction, when the boom gets close to the
vertical position, if the hand wheel can not be turned smoothly, which
means that the spring force is big, users need to loose the spring. Repeat
the below operations and adjustment until the hand wheel can be turned
smoothly, which mean the spring force is at balance status.
Left-(installed) Right-(installed)
Cabinet fixed
at the left of
entrance
Cabinet fixed
at the right of
entrance
(Figure 1)
Motor Hand-wheel
Brushless DC Servo
Motor
Boom
Balance Spring
Initiative Crank
Spring Strength
Regulating
Screw
Spring
Lock-nut
Boom Holder
2
. .3
. .
Expansion Bolts
Reference Size
Cabinet Fixing Bar
(According to the supplementary size)
(Figure 3)

6.3. Mechanism installation direction change
This barrier mechanism can be both left-installed and right-installed.
The users can change the installation direction according to the actual
situation. We will take the left-installed barrier mechanism as an
example. The below description is telling you how to change from
left-installed to right-installed:
6.3.1. Disassemble boom holder: take out the 10MM screw by turning
8MM Allen wrench counterclockwise; And then push out the boom
holder by turning wrench clockwise with a 14MM* 150 screw.
6.3.2. Change the mechanism installation direction: disassemble 6
sets 8MM screws for fixing the mechanism panel, turn the mechanism
180 degrees vertically and put back into the cabinet. And then fix it
with the 6 sets screws.
6.3.3. Assemble boom holder: assemble the boom holder back, and fix
the l0MM screw by turning 8MM Allen wrench clockwise. And then
the mechanism installation direction change is finished.
Take out the 10MM screw by turning
8MM Allen wrench counterclockwise
Push out the boom holder by turning wrench
clockwise with a 14MM* 150 screw
Disassemble
6 sets 8MM
screws
Turn the mechanism 180
degrees vertically
Put the mechanism into
the cabinet Ass e mbl e the boom hold e r
back, and fix the l0M M screw
by turning 8MM Allen wrench
clockwise
(step 3) (step 4)
(step 1) (step 2)
(step 5)
4
. .5
. .

7. Controller Explanations and Instructions
Wire Diagram
Motor Interface
220V/110V
Switch Jumper
Cap 1
UP/D OWN Limit
Signal Output
Interface and
Indicators
Fuse
R & G L i g h t
Interface
P o w e r I n p u t
Interface
MotorEncoder
Interface
MotorSensorIn
terface
RemoteControll
erInterface
DIP Switch 2
Function Indicator
Boom Up Angle Adjustment
Knob
SET
+-
DC12V
<0.2A
L N
Signal Input Indicator
Photocell and Loop Detector
Interface
J1 DIP Switch 1 and Jumper 1
Wire Control Interface
STOP
DOWN
UP
COM
COM Interface
Loop Detector Signal Input
Photocell Signal Input
Photocell Power
Red Light
Green Light
COM
DI P Switch Setting
DIP Switch 1: Speed setting
ON/O N: 3S; OFF/ON: 4S;
ON/O F F: 5S; OFF/OFF: High
intensity of auto-reversing
DIP Switch 2:
DIP 1: Signal type
O F F : No r m a l Op e n , O N :
Normal Close
DIP 2: Learning mode after
power-on
OFF: Boom up and down; ON:
Boom up only
Jumper 1: Auto-aging test
Left: close; Right: open.
Delay Auto-closing Setting
Pressing and holding SET button then power on,
if the Function Indicator constant lighting means
delay auto-closing function is of f if twinkling,
the twinkling times is the seconds of the delay
auto-closing.
Opening method: Press UP button (of the remote
controller) to open this function, after open, the
delay auto-closing time is 3 seconds, each
pressing of the UP button increases by 1 second,
the max is 60 seconds.
Closing method: Press S T O P button, the
Function Indicator constant lighting means close.
Read seconds: Press DOWN button, the Function
Indicator twinkling times is the seconds of the
delay auto-closing.
Release the SET button to save and start
working.
Boom Up Angle
Setting
Counterclockwise
to the end is 60°
Clockwise to the
end is 90°
Middle is end is
60°~85°
Horizontal and vertical fine adjustment
Horizontal adjustment: In U P limit status, pressing
and holding SET button, then press U P button (of the
remote controller) (if angle over 90°) or DO W N
button (if angle less than 90°) to adjust the value
(0~25). Release the SET button, the adjustment is
done when the boom open to the UP limit status next
time.
Vertical adjustment: In DOWN limit status, pressing
and holding SET button, then press O P E N button (of
the remote controller) (if angle less than 0°) or
DOWN button (if angle over 0°) to adjust the value
(0~40). Release the SET button, the adjustment is
done when the boom close to the DOWN limit status
next time.
Note: During adjusting, when press S TOP button, the
twinkling times of the Function Indicator means the
current adjusted value.
7.1. Controller interface explanations
All the electrical connections are done before delivery. The necessity is to
connect the power and grounding connection. Explanations and instructions
for the main function interfaces and indicator light is as following:
7.1.1. 220V/110V switch jumper cap:
This barrier motor and controller support AC220V/110V power input, the
jumper cap is plugged in before delivery, if need to change the input voltage,
please plug the jumper cap into correct position before power on (plug on the
left is 220V, plug on the right is 110V).
7.1.2. R&G light interface:
This function is no power, same as switch, MCOM ” need to connect with
corresponding power of the R&G light. When boom falling down to
horizontal position, red light will keep lighting; when boom lifting up to
vertical position, green light will keep lighting. During the boom falling down
or lifting up, the red light will keep lighting. (Please refer to Appendix II for
wire diagram)
7.1.3. Wire control signal input interface:
This interface is dry contact input signal, UP/ DOWN / STOP connect with
MCOM ”, the control board will respond accordingly. User can use this
interface to connect with parking system, and it can also connect button
switch to control the barrier. (Please refer to Appendix III for drive
requirement for main control board wire control)
7.1.4. Photocell and loop detector interface:
This interface is dry contact input signal, only for responding opening when
shorts circuit MPhotocell” and“ COMH during closing, responding closing
when shorts circuit “ LoopHand MCOMH if opening to up limit position,
responding opening when shorts circuit “ LoopHand MCOMH during
3S 4S 5S Hig h intensity of
auto-reversing
7.1.7. Jumper 1:
This Jumper is for closing (insert left) or opening (insert right) auto-
aging test function; Opening this function can realize barrier gate auto-
open, close, and open during closing process for auto-aging test.
7.1.8. DIP Switch 2:
DIP 1 for setting signal input type, means the wire signal input type of
“STOPH, MLOOP DETECTOR” and “PHOTOCELL”. DIP set to be
OFF, means the barrier responses action when short circuited signal interface
and COM interface; DIP set to be ON, means the barrier responses action
when disconnected signal interface and COM interface.
DIP 2 for learning mode after power-on: set to be OFF, means the
barrier will open and close slowly one time after power-on; set to be
6
. .7
. .

7.1.10. SET button:
This button can set delay auto-closing time and boom horizontal and
vertical fine adjustment.
Power-oFFfirstly, pressing and holding SET button then power on, if the
Function Indicator constant lighting means delay auto-closing function is
oFF; if twinkling, the twinkling times is the seconds of the delay auto-
closing.
Opening method: Press UP button (of the remote controller) to open this
function, after open, the delay auto-closing time is 3 seconds, each pre
ssing of the UP button increases by 1 second,
the max is 60 seconds.
Closing method: Press STOP button, the Function
Indicator constant lighting means close.
Read seconds: Press DOWN button, the Function
Indicator twinkling times is the seconds of the
delay auto-closing.
Release the SET button to save and start working.
(Note: During setting, please don't release SET button)
Boom vertical
adjustment
8. Common Malfunctions and Solutions
8.1. When power-on, press “UP” or “DOWN” button, there is no reaction
on the boom.
8.1.1. Check up the power supply and the fuse.
8.1.2. Check if the remote controller matches the radio receiver; or check up
the battery inside and then change it if it is lack of power.
8.1.3. Check whether there is co-channel interference, and press the buttons
on the control board to check if can work.
8.1.4. Check up if the external protection circuit is failure or in protection
status. Check up the condition of photocell and loop detector are lighting.
8.2. The barrier gate closes half, and then stop learning, during controller
self-test after power-on.
8.2.1. Check up if the boom is installed, the barrier gate need to work with
boom if springs installed.
8.3. Fence boom or 6m boom lifts up automatically when closing.
8.4.1. Set DIP Switch 1 to be OFF position.
9.1. Free service is oFFered for component parts in one year warranty time.
(not includes the barrier boom or remote)
9.2. Lifetime service with charge accordingly.
9.3. Technical questions are supported.
9.4. The below items and situations are not included in the range of free
service:
9.4.1. The user does not follow the instruction and cause any damage of the
product.
9.4.2. The power supply is not stable, over the range of permitted voltage or
not accordant to safety electric using standard.
9.4.3. The user installs or uses the product in wrong methods, cause damage to
the appearance of product.
9.4.4. Natural disaster causes damage to the product.
9.4.5. Warranty time is over.
9.4.6. Service items are out of our promises.
9. Warranty and Service Items
ON, means the barrier will only open slowly (for longer fence boom).
7.1.9. Boom up angle setting:
Counterclockwise to the end is 60°, clockwise to the end is 90°, mid
dle is end is 60°~85°.
Boom horizontal and vertical fine adjustment
Horizontal adjustment: In UP limit status, pressing
and holding SET button, then press UP button
(of the remote controller) (if angle over 90°) or
DOWN button (if angle less than 90°) to adjust
the value (0~25). Release the SET button, the adjustment I
s done when the boom open to the UP limit status next time.
Vertical adjustment: In DOWN limit status, pressing and
holding SET button, then press OPEN button (of the remote
controller) (if angle less than 0°) or DOWN button (if angle over 0°)
to adjust the value (0~40). Release the SET button, the adjustment is
done when the boom close to the DOWN limit status next.
(Note: During adjusting, when press STOP button, the twinkling times
of the Function Indicator means the current adjusted value.)
7.2. Controller auto-detect after power-on description.
The controller should be learning the position of boom after power-on: The
barrier gate will open and then close slowly one time by default. During
learning process, it detects all open and anti-bumping signal interface, and it
Boom horizontal
adjustment
will stop learning if there is signal. After finish leaning, the boom stays at the
down limit position.
The buzzer will sound 1 long and 5 short error, if the barrier installed spring
but no boom, or there is obstruction on the boom during up or down process,
or the spring and boom in serious imbalance, need to remove the obstruction
or adjust the spring, then power-on again.
If learning mode is MBoom up only”, the barrier gate will open to up limit
position, and not close; during learning process of opening, if the barrier can't
open to up limit position due to obstruction, and can't close normally, need to
power on learning again.
8
. .9
. .
Delay auto-closing setting

Name Specification Quantity Unit Application
Screws, Nuts, Flat Pad
Boom Fixing Bar
Boom Holder Plastic Cover
Cabinet Fixing Bar
ExpansionScrews
Support Post
RadioEmitter
Keys
RemoteController
Manual
M12*70
M16*150
2
1
1
2
4
1
1
2
2
1
sets
pcs
sets
pcs
sets
pc
pcs
pcs
pcs
pcs
Fixing theboom
Fixing the boom
Optional
Fixing the cabinet
Fixing the cabinet
Optional
Optional
For cabinet door
10.1. Keep the barrier gate clean.
10.2. Check the joints ever month in case of any loose parts.
10.3. Check the balance status of spring after the barrier gate running 1
million times; change new springs after running 3 million times, to avoid
spring breaking due to excessive fatigue.
10.4. Check the easily worn-out parts every half year and renew it.
10.5. Remote control distance will be shortened or not work in cases like
big object screening, battery exhausting, extreme weathers.
10. Maintenance
11. Packing List
Appendix I. Spring Selection Table
This mechanism comes standard with 1pcs 3.5mm and 1pcs 4.5mm springs.
If the standard springs don't meet the actual boom length requirement,
please replace or add the corresponding spring.
10
. .11
. .
Boom Length(Meter: M)
Straight Boom/Articulated Boom
4≥L≥3
4.5≥L>4
6≥L>4.5
Fence Boom, Two-levels
4>L≥3
4.5≥L≥4
Fence Boom, Three-levels
3≥L≥2
4≥L>3
Spring DiameterΦ (mm)
Link Hole Selection
empty 4.5
3.5 4.5
4.5 4.5
4.5 4.5
5.5 5.5
4.5 4.5
5.5 5.5
DIP switch 1 speed
option in the controller
3.0/4.0/5.0
3.0/4.0/5.0
5.0
4.0/5.0
5.0
4.0/5.0
5.0

Appendix III: Wiring Diagram for R&G Light Interface
Appendix IV. Drive Requirement for Main Control Board
Wire Control
Red & Green light
interface
Red light
Green light
Com wire
Red light wire
Green light wire
Connect R&G light power
Red Com Green
Two types of remote control, multi frequencies for choice. If need to
add or change remote control, methods as following:
1. Learning type
Learning method 1: Before connect power to the barrier gate, keep
pressing button “STOP”, then connect to power, after about 6
seconds, indicator of the receiver from lighting to flashing 4 times
then oFF. That means learning well. (Note: during learning, please
don't loose the button, or you need to relearn).
Learning method 2: Press button “UP” and “STOP” of the well
learning remote controller at the same time for 4 seconds, indictor of
the receiver keep lighting means entering to learning status; during 3
seconds, press button “STOP” of the not learning remote controller
for 2 seconds (or press 2 times continuously), indicator of receiver
flashes 4 times. That means learning well. If the remote controller
doesn't receive any eFFective signal, it will quit learning status.
Clear the code of remote controller: take out the cover of the radio
receiver, and power on, then make short circuit of the left 2 dial plate
on the receiver mould, until the indicator goes out. Then the code of
remote controller is cleared.
2. Fixing type:
The code of remote controller and receiver should be the same.
Coding method: open the remote controller, take out the battery, there
is dial plate, the direction is from right to left. The solder between
middle port and top port is state “1”. The solder between middle port
and bottom port is state “0”. Empty is state “X”. The code as below is
10XX0X1X (Warning: please take out the battery before coding!).
Appendix II: Remote Control Coding
Top “1”is connected with
the18th DIP of the ic
Right
“0”connects with
Bottom the 9th DIP ofthe IC
Left
H
L
18
Line length<5m
Main control
board
Optocoupler PC817
CO M
Optocoupler control mode
Relay control mode
Main control
board
UP
CO M
Drive time>=200ms
Drive time>=200ms
Line length<=10m
12
. .13
. .
Table of contents