EthernetoverCoaxEoCTransceiver
Model NV-EC1701
6 Watt IP Camera
Monitor
Condensed Installation Guide
View the complete guide at www.nvtphybridge.com
NV-EC1701
NV-EC1701 Hybrid
DVRorNVR
Cat5
≤328ft
(≤100m)
Ethernet over
Coax EoC
Transceiver
RG-59/U
20 AWG
Ethernet over
Coax EoC
Transceiver
Cat5
≤328ft
(≤100m)
LAN/WAN
1) Readtheseinstructions.
2) Keep these instructions.
3) Heedallwarnings.
4) Follow all instructions.
1,800 ft(600 m) 55VDC Power Supply
This installation should be made by a qualified service
person and should conform to all local codes.
WARNING - Do not install the unit in an environment
where the operating ambient temperature exceeds
185° F (85° C). The ventilation should not be impeded
by covering the unit with items, such as newspapers,
table-cloths, curtains, etc. No naked flame sources,
5) Do not usethis apparatus near water.
6) Clean only with a dry cloth.
7) Install in accordance with the manufacturer’s instructions.
8) Do not install near any heat sources such as radiators,
heatregisters, stoves or other apparatus (including DVRs)
that produce heat.
9) Do not defeat the safety purpose of the polarized or
grounding-type plug. A polarized plug has two blades with
one wider than the other. A grounding type plug has two
blades and a third grounding prong. The wider blade or the
third prong are provided for your safety. If the provided plug
does not fit into your outlet, consult an electrician for replace-
ment of the obsolete outlet.
10) Protect the power cord from being walked on or pinched
particularly at plugs, convenience receptacles, and the point
wheretheyexit from the apparatus.
11) Only use attachments/accessories specified by the
manufacturer.
12) Refer all servicing to qualified service personnel.
Servicing is required when the apparatushas been damaged
in any way, such as a power supply cord or plug is damaged,
liquid has been spilled, or objects have fallen into the
appara-tus, the apparatus has been exposed to rain or
moisture, does not operate normally, or has been dropped.
This installation should be made by a qualified service person
and should conform to all local codes.
13) BNC Connection: the installation shall be in accordance
with the applicable provisions of the National Electrical Code
ANSI/NFPA 70, Article 800.90 and Canadial Electrical Code
Part 1, Section60-504.
14) RJ45 PoE connection: to be connected only to networks
or circuits that are not routed to outside plant or building.
Page 1 of 2
such as lighted candles should be placed on the
apparatus.
WARNING - Do not interconnect multiple
power supply outputs. Never use more than two
power supplies within a network system. Do not
connect additional loads which would exceed the
marked output current rating of the power supply.
WARNING - The apparatus shall not be exposed to
dripping or splashing and no objects filled with liquids,
such as vases, shall be placed on the apparatus.
WARNING - Use only a Certified power cord and plug
(coupler/ mains) assemblies for location installed.
WARNING - Power cord is regarded as main
disconnect.
WARNING - The appliance coupler (power cord/
mains) shall remain readily operable.
WARNING - For safety, never put NVT Phybridge
signals in the same conduit as high-voltage wiring.
This product is intended to be supplied by a certified power
source marked “Class 2” or “LPS” and rated 48-55 VDC,
30mA minimum, 1,600mA maximum, which may or may not
be provided with the product.
Power supplies, when provided, are external inline, with an
IEC380-C14 power inlet and 6 ft (1.8 m) line-cord. Input
Voltage is 100 ~240 VAC 50-60 Hz. A molded P1J 5.5
mm barrel connector provides a Class 2 (SELV) 48-55
VDC regulated output. Line cord UL approved type SPT-2,
SVT, or SJT, 18/3 AWG Min. 300VAC, 60° C Max. 15 ft
(4.5 m) long. One end with IEC380-C13 appliance coupler
and the other end with NEMA 1015P or equivalent for
country.
Compliance and environmental information
All the compliance and environmental information is
available on our website www.nvtphybridge.com
NVT Phybridge
888.901.3633 | +44 (0) 208 977 6614
www.nvtphybridge.com
The NVT Phybridge Model NV-EC1701 Ethernet over Coax
EoC Transceiver is a compact media converter that allows
10/100BaseTEthernet and PoE,PoE+,or high-power PoE to
be transmitted using coax cable. These EoC devices are
typically used in legacy installations where existing coax is
redeployed as part of an upgrade to IP cameras. 48-55VDC
class2 poweris deliveredtoonetransceiver,which distributes
it to multiple remote transceivers, and theirPoE cameras.
Thesetransceivers are extremely simple to use, with no IP or
MACaddress configuration required.Status LEDs indicate
power and link connectivity/activity for RJ45 and BNC ports.
The NV-EC1701 is backed by NVT Phybridge’s award
winning customer support and limited lifetime warranty.
Before installing, NVT Phybridge recommends
downloading and reading thecomplete installation
manual from www.NVTPhybridge.com.
Transceiversmustbeconfiguredpriortouse. Seepage2.
Use one NV-EC1701transceiverat each end of the coax. Up
to four remote transceivers and coax runs may be connected
to a fifth transceiver at the control room using the
NV-EC4BNC adaptor/splitter. Multiple splitters may be used
for larger systems.
Set the NV-EC1701 PoE toggle switch (located near the BNC
connector) to ON if the connected IP device requires PoE to
be delivered by the NV-EC1701 and to OFF if PoE should not
be delivered by NV-EC1701. This setting relates to power
delivery at the Ethernet RJ45 connection.
Connecta 55VDCpowersupplyinto one ofthetransceiversto
provide power to the entire system, including the cameras.
Data signalsoverthe coax are capable ofextendeddistances,
however voltage-drop in the 55V power distribution will often
reduce this maximum, depending on the camera’s current
drawandwire resistance.
Note: Within one network, up to two power supplies may
bedeployed to supportextended wire distances or higher
camera loads.
Copyright © 2016 NVT Phybridge
451-1701-1-H1
2016/12
INSTALLATION INSTRUCTIONS
TO REDUCE THE RISK OF ELECTRICAL
DO NOT EXPOSE THIS APPARATUS TO RAIN OR
REDUCE THE RISK OF ELECTRICAL SHOCK, DO
REMOVE COVER OR BACK. NO USER
PARTS INSIDE. REFER SERVICING
QUALIFIED SERVICE PERSONNEL.
IMPORTANT SAFETY INSTRUCTIONS
PRODUCT DESCRIPTION