manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. NVT Phybridge
  6. •
  7. Transceiver
  8. •
  9. NVT Phybridge NV-EC1701 User manual

NVT Phybridge NV-EC1701 User manual

NEW FEATURE
!
!
!
!
!
!
!
EthernetoverCoaxEoCTransceiver
Model NV-EC1701
6 Watt IP Camera
Monitor
Condensed Installation Guide
View the complete guide at www.nvtphybridge.com
NV-EC1701
NV-EC1701 Hybrid
DVRorNVR
Cat5
≤328ft
(≤100m)
Ethernet over
Coax EoC
Transceiver
RG-59/U
20 AWG
Ethernet over
Coax EoC
Transceiver
Cat5
≤328ft
(≤100m)
LAN/WAN
1) Readtheseinstructions.
2) Keep these instructions.
3) Heedallwarnings.
4) Follow all instructions.
1,800 ft(600 m) 55VDC Power Supply
This installation should be made by a qualified service
person and should conform to all local codes.
WARNING - Do not install the unit in an environment
where the operating ambient temperature exceeds
185° F (85° C). The ventilation should not be impeded
by covering the unit with items, such as newspapers,
table-cloths, curtains, etc. No naked flame sources,
5) Do not usethis apparatus near water.
6) Clean only with a dry cloth.
7) Install in accordance with the manufacturer’s instructions.
8) Do not install near any heat sources such as radiators,
heatregisters, stoves or other apparatus (including DVRs)
that produce heat.
9) Do not defeat the safety purpose of the polarized or
grounding-type plug. A polarized plug has two blades with
one wider than the other. A grounding type plug has two
blades and a third grounding prong. The wider blade or the
third prong are provided for your safety. If the provided plug
does not fit into your outlet, consult an electrician for replace-
ment of the obsolete outlet.
10) Protect the power cord from being walked on or pinched
particularly at plugs, convenience receptacles, and the point
wheretheyexit from the apparatus.
11) Only use attachments/accessories specified by the
manufacturer.
12) Refer all servicing to qualified service personnel.
Servicing is required when the apparatushas been damaged
in any way, such as a power supply cord or plug is damaged,
liquid has been spilled, or objects have fallen into the
appara-tus, the apparatus has been exposed to rain or
moisture, does not operate normally, or has been dropped.
This installation should be made by a qualified service person
and should conform to all local codes.
13) BNC Connection: the installation shall be in accordance
with the applicable provisions of the National Electrical Code
ANSI/NFPA 70, Article 800.90 and Canadial Electrical Code
Part 1, Section60-504.
14) RJ45 PoE connection: to be connected only to networks
or circuits that are not routed to outside plant or building.
Page 1 of 2
such as lighted candles should be placed on the
apparatus.
WARNING - Do not interconnect multiple
power supply outputs. Never use more than two
power supplies within a network system. Do not
connect additional loads which would exceed the
marked output current rating of the power supply.
WARNING - The apparatus shall not be exposed to
dripping or splashing and no objects filled with liquids,
such as vases, shall be placed on the apparatus.
WARNING - Use only a Certified power cord and plug
(coupler/ mains) assemblies for location installed.
WARNING - Power cord is regarded as main
disconnect.
WARNING - The appliance coupler (power cord/
mains) shall remain readily operable.
WARNING - For safety, never put NVT Phybridge
signals in the same conduit as high-voltage wiring.
This product is intended to be supplied by a certified power
source marked “Class 2” or “LPS” and rated 48-55 VDC,
30mA minimum, 1,600mA maximum, which may or may not
be provided with the product.
Power supplies, when provided, are external inline, with an
IEC380-C14 power inlet and 6 ft (1.8 m) line-cord. Input
Voltage is 100 ~240 VAC 50-60 Hz. A molded P1J 5.5
mm barrel connector provides a Class 2 (SELV) 48-55
VDC regulated output. Line cord UL approved type SPT-2,
SVT, or SJT, 18/3 AWG Min. 300VAC, 60° C Max. 15 ft
(4.5 m) long. One end with IEC380-C13 appliance coupler
and the other end with NEMA 1015P or equivalent for
country.
Compliance and environmental information
All the compliance and environmental information is
available on our website www.nvtphybridge.com
NVT Phybridge
888.901.3633 | +44 (0) 208 977 6614
www.nvtphybridge.com
The NVT Phybridge Model NV-EC1701 Ethernet over Coax
EoC Transceiver is a compact media converter that allows
10/100BaseTEthernet and PoE,PoE+,or high-power PoE to
be transmitted using coax cable. These EoC devices are
typically used in legacy installations where existing coax is
redeployed as part of an upgrade to IP cameras. 48-55VDC
class2 poweris deliveredtoonetransceiver,which distributes
it to multiple remote transceivers, and theirPoE cameras.
Thesetransceivers are extremely simple to use, with no IP or
MACaddress configuration required.Status LEDs indicate
power and link connectivity/activity for RJ45 and BNC ports.
The NV-EC1701 is backed by NVT Phybridge’s award
winning customer support and limited lifetime warranty.
Before installing, NVT Phybridge recommends
downloading and reading thecomplete installation
manual from www.NVTPhybridge.com.
Transceiversmustbeconfiguredpriortouse. Seepage2.
Use one NV-EC1701transceiverat each end of the coax. Up
to four remote transceivers and coax runs may be connected
to a fifth transceiver at the control room using the
NV-EC4BNC adaptor/splitter. Multiple splitters may be used
for larger systems.
Set the NV-EC1701 PoE toggle switch (located near the BNC
connector) to ON if the connected IP device requires PoE to
be delivered by the NV-EC1701 and to OFF if PoE should not
be delivered by NV-EC1701. This setting relates to power
delivery at the Ethernet RJ45 connection.
Connecta 55VDCpowersupplyinto one ofthetransceiversto
provide power to the entire system, including the cameras.
Data signalsoverthe coax are capable ofextendeddistances,
however voltage-drop in the 55V power distribution will often
reduce this maximum, depending on the camera’s current
drawandwire resistance.
Note: Within one network, up to two power supplies may
bedeployed to supportextended wire distances or higher
camera loads.
Copyright © 2016 NVT Phybridge
451-1701-1-H1
2016/12
INSTALLATION INSTRUCTIONS
WARNING:
TO REDUCE THE RISK OF ELECTRICAL
SHOCK,
DO NOT EXPOSE THIS APPARATUS TO RAIN OR
MOISTURE.
TO
REDUCE THE RISK OF ELECTRICAL SHOCK, DO
NOT
REMOVE COVER OR BACK. NO USER
SERVICEABLE
PARTS INSIDE. REFER SERVICING
TO
QUALIFIED SERVICE PERSONNEL.
IMPORTANT SAFETY INSTRUCTIONS
PRODUCT DESCRIPTION
Condensed Installation Guide
View the complete guide at www.nvtphybridge.com
NV-EC1701 EoC transceivers transmit high bandwidth encrypted Ethernet signals over conventional coax cables. To provide utmost signal integrity and security, the
NV-
EC1701 transceivers must be configured to communicate exclusively with other transceivers within their Network Group. This group typically consists of one
NV-EC1701
located at the control room (usually connected to an Ethernet switch or router), and multiple remote NV-EC1701 transceivers (usually connected to IP cameras).
The NV-EC1701 now comes in auto join mode for easy and quick deployments. The joining process is now only required when deploying more than 1 group of NV-EC1701 units.
When deploying more than 1 group (max 4 end points and 1 head end) you are required to factory default the groups after the first group. You must first factory default the units
in the next group so they can be joined together into a group. Follow the un-joining method listed below and once factory defaulted you can then move to Step 3 to join the newly
factory defaulted units together.
Step One: Gather Materials
●
NV-EC1701 transceivers
●
55V power supply & line-cord (NV-PS55-60W)
●
Coax jumper
●
Small paper-clip, partially straightened:
●
Device labels
Coaxjumper
Step One: Gather Materials
55V power supply
●
IP Network Documentation Log
Step Two: Connect Hardware
●
Remove and discard the “Configure Before Use”labels.
●
Connect two NV-EC1701 transceivers using a coax jumper.
●
Connect a 55V power supply to transceiver #1; Apply power.
●
Verify that the blue POWER LED on each transceiver illuminates.
●
Beforeproceedingtonextstep,waitforanygreenBNCLEDthatcameon
duringstartuptogooff,approximately10seconds.
Step Three: Joining
●
On transceiver #1, using the straightened paper-clip to access the small
push-button located behind and slightly above the RJ45 LED.
Firmly press and release this button.
The blue Power LED will begin blinking.
●
Then firmly pressand release the same push-button on transceiver #2.
The blue Power LED willbegin blinking.
Paper-clip (slightly straightened)
NV-EC1701 transceivers
Step Two: Connect Hardware
55V power supply
& line-cord (NV-PS55-60W)
& line-cord (NV-PS55-60W)
Coaxjumper
●
Both transceivers have now entered
Join Mode.
They will find each other and establish encrypted communication.
In about 10 seconds, the blue Power LEDs on both transceivers will return
to a steady on condition, 'and the green BNC LEDs willilluminate indicating
a successful join.
Step Four: Adding Transceivers
(ifrequired)
●
Disconnect transceiver #2 andreplace it with a new un-joined transceiver (#3, or #4,or #5).
●
Repeat steps two and three to addadditional transceivers to the same Network Group.
StepFive: Documentation
●
Label the configured transceivers with a unique Network Group ID of your choice.
This will help you identify them after they have been deployed.
●
Record this Network Group information in your IP Network Documentation Log.
This log may include essential documentation which will help you identify all
system devices during and after deployment:
Transceiver #1 Transceiver #2
StepThree:
Transparent view of push-button location
●CameraNumber
●CameraPosition/Location
●Camera Make & Model
●CameraMAC & IP Address
●CameraLogin & Password
Un-JoiningaTransceiver
●Camera-end NVTPhybridgeTransceiverMAC Address
●NVTPhybridge TransceiverNetwork Group Name
●Control Room NVT PhybridgeTransceiver MAC Address
●Control Room RouterPort Number
If you need to move a transceiver from one Network Group to another, it must first un-learn its
previous Network Group and be returned to an un-joined state. Do this by performing these
steps:
●
Disconnect the transceiver from the old network.
●
Connect a 55 VDC power supply to a transceiver.
●
Wait until its green BNC LED is lit.
●
Using the straightened paper-clip to accessthe small push-button located behind
and slightly above the RJ45.
Press and hold this button for 10-12 seconds until all of the LEDs flash.
●
Release the paperclip.
●
Observe that the green BNC LED goes on for ten seconds and then goes off.
Un-joining is now complete. If you are not sure that un-joining has been successful,
remove and then re-apply power, and repeat.
Page 2 of 2
NVT Phybridge
888.901.3633 | +44 (0) 208 977 6614
www.nvtphybridge.com
Copyright © 2016 NVT Phybridge
451-1701-1-H1
2016/12
CONFIGURATION INSTRUCTIONS

Other NVT Phybridge Transceiver manuals

NVT Phybridge NV-EC1701U User manual

NVT Phybridge

NVT Phybridge NV-EC1701U User manual

NVT Phybridge NV-EC1701 User manual

NVT Phybridge

NVT Phybridge NV-EC1701 User manual

NVT Phybridge NV-EC1701U User manual

NVT Phybridge

NVT Phybridge NV-EC1701U User manual

Popular Transceiver manuals by other brands

Midland BASE CAMP446 Service manual

Midland

Midland BASE CAMP446 Service manual

Cobalt Digital Inc 9450GT Series product manual

Cobalt Digital Inc

Cobalt Digital Inc 9450GT Series product manual

AHHA-Tech EZBee S100 manual

AHHA-Tech

AHHA-Tech EZBee S100 manual

Alcatel-Lucent OmniSwitch 6800 Series user guide

Alcatel-Lucent

Alcatel-Lucent OmniSwitch 6800 Series user guide

Delta Electronics LCP-155B4MSRx Series Specification sheet

Delta Electronics

Delta Electronics LCP-155B4MSRx Series Specification sheet

Kenwood TM-3530A instruction manual

Kenwood

Kenwood TM-3530A instruction manual

LYNXTechnik yellobrik OTR 1240 quick reference

LYNXTechnik

LYNXTechnik yellobrik OTR 1240 quick reference

Cypress WiFi3309701 user manual

Cypress

Cypress WiFi3309701 user manual

XIEGU G90 Operation manual

XIEGU

XIEGU G90 Operation manual

Yaesu FTDX10 Reference manual

Yaesu

Yaesu FTDX10 Reference manual

Ten-Tec 555 Operator's manual

Ten-Tec

Ten-Tec 555 Operator's manual

Craig L232 Service manual

Craig

Craig L232 Service manual

Kenwood TK-2402 instruction manual

Kenwood

Kenwood TK-2402 instruction manual

WattMaster CommLink IV Technical guide

WattMaster

WattMaster CommLink IV Technical guide

Hirschmann Mini-OTDE Description and operating instructions

Hirschmann

Hirschmann Mini-OTDE Description and operating instructions

COP EA-EOU101K instructions

COP

COP EA-EOU101K instructions

Philips IntelliVue TRx Instructions for use

Philips

Philips IntelliVue TRx Instructions for use

Tsuen Shing WT-555 user manual

Tsuen Shing

Tsuen Shing WT-555 user manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.