Safety instructions for all Maximus Eco Models
Introduction
All pumps are intended for submersible use. To ensure optimum performance and safety
from you Maximus Eco pump please comply with the following instructions.
The pump comes complete with 10 mtrs of 3 core cable, however, should any additional cable be
required then the use of an approved waterproof cable connector is essential.
!The power supply must be earthed and fused at 3amps.
!Regularly inspect the cable for damage and deterioration
!Always use a residual circuit device (RCD) for additional safety
!For permanent installation to the mains supply, it is necessary to comply with the regulations of the
Local Electricity Authority.
!Consult a qualified electrician if in doubt about any aspects of wiring.
ELECTRICAL CONNECTIONS
NEUTR AL = BLUE N
EARTH = GREEN & YELLOW
LIVE = BROWN L
INSTALLATION
WINTER MONTHS
LOW FLOW TO WATERFALL /FILTER OR LOW FOUNTAIN JET
PUMP DOES NOTAPPEAR TO BE WORKINGAT ALL
WARNING: Always unplug or disconnect the pump from the electrical supply before putting your hands (or any part of your
body) in the water or whilst the pump is being installed, repaired, maintained or handled.
·All pumps are intended for submersible use and MUST BE under water at all times for proper operation and cooling.
·Never run a pump dry.
·The pump should be installed on a firm base in the pond so that the fountain jet is just above the surface of the water.
·If needed, the telescopic pipe can be adjusted in length (all models) and moved to find the vertical position (from model
1200).
During the winter months, when most decorative fountains are not required, the pump should either be removed from the pond
and thoroughly dried or operated for a few minutes every week to ensure that the rotating parts remain free.
During frosty periods, operation of the pump with the fountain jet removed will assist in preventing the pond from freezing
over.
·Check the power supply is properly connected and working.
·Check fuse.
·Disconnect electrical supply. Remove pump and follow maintenance instructions.
Check outer shell is clean. Check hose is not blocked or kinked.
Check impeller cover is clean. Check fountain jet is clean.
Check waterfall connection is not blocked Check pump flow adjuster is not set to minimum.
Check t-piece flow adjuster is not set too low.
Maintenance Maximus Eco 800/12000
Maintenance Maximus Eco 1700/2300/3000
1. Disconnect pump from the
mains/electrical supply.
2. Remove outer shell and clean
in water.
3. Remove impeller cover by
rotating anti-clockwise.
Inspect and clean if
necessary.
4. Withdraw the magnet/impeller
assembly: Inspect and clean it
if necessary. Check there is
no limescale built up on
magnet: If the impeller is
cracked - replace it.
5. Reassembly is a straight
forward reversal of the above
procedure.
1. Disconnect pump from
the mains/electrical
supply.
2. Remove outer shell and
clean in water.
3. Remove impeller cover
by rotating anti-
clockwise. Inspect and
clean if necessary.
4. Withdraw the magnet/
impeller assembly all
together with ceramic
shaft and rubber cups
CAUTION: Ceramic shaft is hard but brittle. Inspect and clean magnet, impeller, shaft
and rubber cups if necessary. Check there is no limescale built up on the magnet.
Check for hairline cracks on magnet: if cracked, replace it.
5. Reassembly is a straight forward reversal of the above procedure.
8001200
1700/2300/30004500/6000/8000
MAXIMUS PUMPS FOUNTAIN JETS
T Piece
Flow
Adjuster
T Piece
Flow
Adjuster
T Piece
Flow
Adjuster
Flow Adjuster/Water inlet
Impeller
Pump Body
Pump Outlet
Flow Adjuster/Water inlet
Impeller
Pump Outlet
Pump Body