WARRANTY
For 36 months (3 years) from the date of purchase OAL will repair or replace this pump, free of charge, if
defective in material or workmanship. The ceramic bearings and shaft contained within this pump are
guaranteed for the life of the pump. The maintenance schedule must be followed. This warranty will be invalid
if the pump is not maintained in accordance with the instructions within this manual.- To claim please see
below.
LIMITATION OF WARRANTY
OAL will not be liable for normal "wear and tear'' items as indicated in this owners manual. No liability is
assumed with regard to loss or damage of livestock or property irrespective of the cause thereof. This warranty
does not affect your statutory rights. Failure caused by misuse is not covered by this warranty.
This warranty is invalid if the product fails as the result of accidental damage, improper installation, or failure to
maintain as directed in this owners manual. Neglect, misuse, modification or use with any liquid other than
fresh, clean water (above freezing point, but below +35C) will invalidate this warranty. The use of this pump
below the rated depth (2 metres) will invalidate this warranty. Running this pump dry or without the pump
body/base cover will invalidate this warranty.
HOW TO CLAIM
DO NOT return the pump to the retailer. Either contact us by telephone/email or send the pump, securely
packed With your name and address. Enclose a brief note advising the nature of the fault. If repair is
claimed under warranty, proof of purchase receipt MUST be returned with the pump.
1. Disconnect pump from
the mains electrical
supply.
2. Remove outer shell and
clean in water.
3. Remove the 3 Screws
4. Remove impeller housing
Inspect and clean if
necessary.
5. Inspect site of impellor
housing and o-ring. Clean
if necessary.
6. Check impeller for any
debris. Clean if
necessary.
7. Check if impeller runs
freely: if not, rotate
several times until
impeller is free to rotate.
8. There are no other consumer maintenance items in these pumps.
9. Reassembly is a straightforward reversal of the above procedure.
Maintenance Maximus Eco 4500-6000-8000
800, 1200, 1700, 2300, 3000, 4500,
6000 & 8000
800, 1200, 1700, 2300, 3000, 4500,
6000 & 8000
INSTALLATION
AND
MAINTENANCE
INSTRUCTIONS
INSTALLATION
AND
MAINTENANCE
INSTRUCTIONS
Water Inlet
Pump Outlet
Impeller
Pump Body
* Depending on model - Compared to previous Maximus Pump Models
Safety instructions for all Maximus Eco Models
Introduction
All pumps are intended for submersible use. To ensure optimum performance and safety
from you Maximus Eco pump please comply with the following instructions.
The pump comes complete with 10 mtrs of 3 core cable, however, should any additional cable be
required then the use of an approved waterproof cable connector is essential.
!The power supply must be earthed and fused at 3amps.
!Regularly inspect the cable for damage and deterioration
!Always use a residual circuit device (RCD) for additional safety
!For permanent installation to the mains supply, it is necessary to comply with the regulations of the
Local Electricity Authority.
!Consult a qualified electrician if in doubt about any aspects of wiring.
ELECTRICAL CONNECTIONS
NEUTR AL = BLUE N
EARTH = GREEN & YELLOW
LIVE = BROWN L
INSTALLATION
WINTER MONTHS
LOW FLOW TO WATERFALL /FILTER OR LOW FOUNTAIN JET
PUMP DOES NOTAPPEAR TO BE WORKINGAT ALL
WARNING: Always unplug or disconnect the pump from the electrical supply before putting your hands (or any part of your
body) in the water or whilst the pump is being installed, repaired, maintained or handled.
·All pumps are intended for submersible use and MUST BE under water at all times for proper operation and cooling.
·Never run a pump dry.
·The pump should be installed on a firm base in the pond so that the fountain jet is just above the surface of the water.
·If needed, the telescopic pipe can be adjusted in length (all models) and moved to find the vertical position (from model
1200).
During the winter months, when most decorative fountains are not required, the pump should either be removed from the pond
and thoroughly dried or operated for a few minutes every week to ensure that the rotating parts remain free.
During frosty periods, operation of the pump with the fountain jet removed will assist in preventing the pond from freezing
over.
·Check the power supply is properly connected and working.
·Check fuse.
·Disconnect electrical supply. Remove pump and follow maintenance instructions.
Check outer shell is clean. Check hose is not blocked or kinked.
Check impeller cover is clean. Check fountain jet is clean.
Check waterfall connection is not blocked Check pump flow adjuster is not set to minimum.
Check t-piece flow adjuster is not set too low.
Maintenance Maximus Eco 800/12000
Maintenance Maximus Eco 1700/2300/3000
1. Disconnect pump from the
mains/electrical supply.
2. Remove outer shell and clean
in water.
3. Remove impeller cover by
rotating anti-clockwise.
Inspect and clean if
necessary.
4. Withdraw the magnet/impeller
assembly: Inspect and clean it
if necessary. Check there is
no limescale built up on
magnet: If the impeller is
cracked - replace it.
5. Reassembly is a straight
forward reversal of the above
procedure.
1. Disconnect pump from
the mains/electrical
supply.
2. Remove outer shell and
clean in water.
3. Remove impeller cover
by rotating anti-
clockwise. Inspect and
clean if necessary.
4. Withdraw the magnet/
impeller assembly all
together with ceramic
shaft and rubber cups
CAUTION: Ceramic shaft is hard but brittle. Inspect and clean magnet, impeller, shaft
and rubber cups if necessary. Check there is no limescale built up on the magnet.
Check for hairline cracks on magnet: if cracked, replace it.
5. Reassembly is a straight forward reversal of the above procedure.
8001200
1700/2300/30004500/6000/8000
MAXIMUS PUMPS FOUNTAIN JETS
T Piece
Flow
Adjuster
T Piece
Flow
Adjuster
T Piece
Flow
Adjuster
Flow Adjuster/Water inlet
Impeller
Pump Body
Pump Outlet
Flow Adjuster/Water inlet
Impeller
Pump Outlet
Pump Body

This manual suits for next models

7

Popular Water Pump manuals by other brands

Xylem Bell & Gossett 60 Series instruction manual

Xylem

Xylem Bell & Gossett 60 Series instruction manual

DanPumps S-IP installation manual

DanPumps

DanPumps S-IP installation manual

Liberty Pumps 2LE Series installation manual

Liberty Pumps

Liberty Pumps 2LE Series installation manual

Liberty Pumps Pro370 Series installation manual

Liberty Pumps

Liberty Pumps Pro370 Series installation manual

Watson-Marlow qdos H-FLO Reference manual

Watson-Marlow

Watson-Marlow qdos H-FLO Reference manual

BUSCH COBRA NC 0600 C instruction manual

BUSCH

BUSCH COBRA NC 0600 C instruction manual

Wright Flow Technologies TR-IS Series Installation, operation and maintenance manual

Wright Flow Technologies

Wright Flow Technologies TR-IS Series Installation, operation and maintenance manual

Pumpex K 82 Service instruction

Pumpex

Pumpex K 82 Service instruction

SAMES KREMLIN AZUR 52C225 user manual

SAMES KREMLIN

SAMES KREMLIN AZUR 52C225 user manual

FLORABEST FTP 400 B2 translation of original operation manual

FLORABEST

FLORABEST FTP 400 B2 translation of original operation manual

Concentric 4F649 Operating instructions & parts manual

Concentric

Concentric 4F649 Operating instructions & parts manual

Weq CFW700 Series Applications manual

Weq

Weq CFW700 Series Applications manual

Ashland EPH30 OPERATION, PERFORMANCE, SPECIFICATIONS and PARTS MANUAL

Ashland

Ashland EPH30 OPERATION, PERFORMANCE, SPECIFICATIONS and PARTS MANUAL

JABSCO 36600-0000 Product guide

JABSCO

JABSCO 36600-0000 Product guide

Neptun Classic NCTP-O 300i operating instructions

Neptun

Neptun Classic NCTP-O 300i operating instructions

DÖRR EcoPUC MC Operation manual

DÖRR

DÖRR EcoPUC MC Operation manual

BorMann PRO BGB1000 user manual

BorMann

BorMann PRO BGB1000 user manual

Danfoss Series 42 Service manual

Danfoss

Danfoss Series 42 Service manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.