OCTOdent HP Serieis User manual

Aerosol Suction Unit
Product Manual

TABLE OF CONTENTS
OVERVIEW 1
PRODUCT FEATURES 2
PACKING LIST 3
FILTERS 4
INSTALLATION INSTRUCTIONS 5
STRUCTURE 6
CONTROL PANEL AND REMOTE CONTROL 7
FAQ AND SOLUTIONS 8
WARRANTY 9

Overview
Specifications
This product is a mobile extra-oral smoke suction machine, which quickly lters spray, aerosol,
bacteria, and other harmful substances during the treatment, by utilizing the high negative pressure
produced by a brushless direct current motor.
The rst step in using a washing primary cotton lter and secondary water vapor absorbing lter
out spray, thin blood, scraps, and other large particles during the treatment.
The second step is to lter out 99.97% of the smell and aerosol through customized H13 HEPA
highly efcient lter and active carbon lter.
The last step is through the UVC photo oxygen catalytic sterilization module, which sterilizes and
expels it to the outside. Tower-like lters to purify the air. In conclusion, this products can make the
air clean and fresh, improve the cleanliness of the treatment environment, reduce the rate of viral
cross-infection, and thus achieve the goal of ghting infection.
Series HP XT
Voltage AC220V 60Hz/AC110 60Hz AC220V 60Hz/AC110 60Hz
Power 180W 220W
Air Volume 310m3/h 310m3/h
Noise ≤52db(A) ≤52db(A)
Filtration 0.3μ m 99% 0.3μ m 99%
Length Of Tube 4’ 7” 4’ 7”
Size L16” x W10” x H22” L16” x W10” x H24”
Weight 46lb 53lb
Size Of Flange 3” 3”
1

Product Features
CENTRIFUGAL FAN
The fan has a brushless direct current motor with a maximum service life of 40 thousand hours.
Needless to maintenance. High-reliability assurance. Low operating noise. High rotation speed,
high air volume, high air pressure, and high efciency can be achieved.
LCD DISPLAY
Independently developed microcomputer LCD with programmable single chip bringing digital
control. A simple interface is displaying operating parameters. The mode of the fan is automatically
checked. When there is pipe blocked, lter saturated, and other situations, the system will
automatically alarm with a signal and a sound. It operates with low-pressure power to improve
safety.
REMOTE CONTROL
This product can remotely control basic on-off instructions, accelerate and decelerate, timed
shutdown functions. It uses 2.4G wireless technology to achieve 360-degree control within 20
meters. Easy and convenient operations enable exibility.
FILTERS
There are ve levels and ve layers of lter systems:
Washable primary effective lters, water vapor absorbing lter, H13 HEPA lter, active carbon lter,
and UVC photo oxygen catalytic sterilization system.
The rst step is using a washable primary cotton lter and secondary water vapor absorbing lter
to effectively lter out spray, thin blood, scraps, and other large particles during the treatment.
The second step is to lter out 99.97% of the smell and aerosol through customized H13 HEPA
highly efcient lter and active carbon lter. The last step is through the UVC photo oxygen
catalytic sterilization module, which sterilizes and expels it to the outside. Tower-like lters to purify
the air.
In conclusion, this product can make the air clean and fresh, improve the cleanliness of the
treatment environment, reduce the rate of viral cross-infection, and thus achieve the goal of
ghting infection.
2

Packing list
Description QTY Size Model Note
Main Machine 1 Set
L16” x W10” x H22”
L16” x W10” x H24”
HP
XT
Power Cord 1 Piece 5’ 10” Connect with
machine
Smoking Tube 1 Piece 4’ 7”
User’s Manual 1 Book
Washable Primary
Effective Filter 2 Piece L14” x W8.7” x H.04” AS01
H13 HEPA 1 Piece L14” x W8.7” x H4” AS02
Water Vapor
Absorbing Filter 1 Piece L14” x W8.7” x H2” AS03
Active Carbon Filter 1 Piece L14” x W8.7” x H2” AS04 Only XT
UVC Lamp 1 Piece 10w AS05
Plasma 1 Piece AS06 Options
2.4G Remote Control 1 Piece
Note: The Filter Element Is Placed Inside The Machine
3

Filters
Description Replacement Period Replacing Method
Washable Primary
Effective Filter 7-15 Days Pull Out
Water Vapor Absorbing
Filter 2-4 Months Pull Out
H13 HEPA 6-8 Months Pull Out
Active Carbon Filter 6-8 Months Pull Out
UVC Lamp 6-8 Months Remove The Chassis Bottom
Cover
4

structure
1 Air Inlet
2 Control Panel
3 Plexi-Logo
4 Filter Door
5 Three-In-One Switch
6 Filters Door Latch Plate
7 Universal Wheel
5

6

TIMED SHUTDOWN SETTINGS
When the machine is running, press this key to display the HXXX on the display screen, and then
adjust the specic time of timing shutdown according to the increasing and decrease of wind
speed. When setting eh timing, press the timing key again to adjust the shifty of the number of
times, tens and hundreds. After setting, press the OK setting setting key to conrm the end of the
timing device.
Among them, XXX represents the number of hours the machine operates at a xed time, with a
maximum of 300 hours and a minimum of 1 hour. After setting, press the timing key to query the
remaining time of the timing. The display screen displays HXXX. For example, H005 represents the
machine will automatically shut down after 5 hours. Set the time to H000 can eliminate the timing.
REMOTE TIMED SHUT DOWN
When the machine is running, press this key to
display HXXX on the nixie tube display screen,
and then adjust the specic time of timing
shutdown according to the increase and
decrease of wind speed, wherein XXX represents
the hours of the timing operation of the machine,
with the maximum of 300 hours and the minimum
of 1 hour.
After setting, press the timing key to query the
timing time. The display shows HXXX. For
example, H005 represents the machine will
automatically shut down after 5 hours. Set the
time to H000 can eliminate the time.
7

FA & Solutions
1. The system is still working, but the air volume is weak, and the suction force is signicantly
reduced.
Cause:The air intake is blocked, or there is foreign matter in the pipe, and the lter element reaches
saturation failure, resulting in a blocking alarm. Check: turn off the power supply, check whether there
is any foreign matter blocking the air intake, and then check whether the air outtake is blocked. If the
suction of the air compressor is normal, the lter element needs to be replaced.
2. After the machine starts, it will shut down automatically, repeat the above phenomenon
appear when turning on again.
Cause:The internal airow is blocked, and the lter element resistance is too large, which leads to
excessive starting current of the fan, and the ma- chine will automatically protect and shut down.
Check: turn off the power supply and check whether there is any foreign matter blocking the air intake;
if there is no abnormality, adjust the air volume to the minimum, re- start the machine and adjust the air
volume to the appropriate position.
3. Turn on the power switch and the indicator light is not on.
Check whether the socket is in poor contact. If the power socket is in good condition, check whether
the fuse in the power box is burnt. If it is dam- aged, replace the fuse.
Be sure to turn off the power before checking and repairing the equipment!
8

Warranty
As for the warranty (free repair) of goods within the warranty period, it shall be implemented from the
date of purchase.
1. During the warranty period, the goods can only be repaired in OCTOdent headquarters or dealers
recognized by OCTOdent. Please show us this User’s manual(Warranty) and purchase invoice.
2. From the date of purchase, the main unit is guaranteed for 1 year. (Note: the lter element belongs
to consumables and is not under warranty Scope of repair)
3. Under one of the following circumstances, even within the warranty period, it can not be treated as a
warranty, but it can be bank charge processing:
A) Damage caused by use, maintenance and storage not under the operating instructions;
B) Damage caused by incorrect operation, abnormal power supply, and falling;
C) Damage caused by dismantling the machine without the consent of the manufacturer;
D) Failure to prove that the machine is within the valid warranty period;
E) The information on the warranty certicate is inconsistent with or altered from the physical
identication of the goods;
F) Damage due to nuclear and chemical corrosion;
G) Damage due to force measures (lightning, earthquake, ood, re, and other natural disasters).
4. OCTOdent company reserves the right of nal interpretation of after-sales service terms.
OCTOdent customer consulting service center
Service hotline: 870-224-0966
Ofcial website: www.octodent.com
9

MANUFACTURER
OCTOdent
ADDRESS: 1523 HWY 65 N Harrison, AR 72601
WEBSITE: www.octodent.com
TEL: 870-224-0966
EMAIL: [email protected]
EXPORTER
OCTOdent
ADDRESS: 1523 HWY 65 N Harrison, AR 72601
WEBSITE: www.octodent.com
TEL: 870-224-0966
EMAIL: [email protected]
10
This manual suits for next models
1
Table of contents
Popular Dental Equipment manuals by other brands

Durr Dental
Durr Dental Duo Tandem Installation and operating instructions

DENTSPLY
DENTSPLY Degulux soft-start manual

Renfert
Renfert Waxprofi 1440-0000 instruction manual

B.A. International
B.A. International Powersurge Instructions for use

KaVo
KaVo PROPHYflex 4 Perio Kit Instructions for use

DENTSPLY
DENTSPLY Dispersalloy Directions for use