Offgridtec 8-01-017865 User manual

User Manual
When displaying the TARIFF 1 , press and hold the [Set] button for 3 seconds to enter the rate setting.
Press [+] or [-] to select between TARIFF1 and Dual Tariff.
Press the [OK] key to confirm your choice and enter the next setting menu.
If your choice is single rate/tariff,
Press [+] or [-] to select the setting data.
Press the [History] key to switch between digit positions.
Press the [OK] key to confirm the current setting.
If your choice is dual rate/tariff,
Press [+] or [-] to select the setting data.
Press the [History] key to switch between digit positions.
Press the [OK] key to confirm the current setting and please refer to following example
{Example: Setting Double Rate}
Rate 1: 1.00 $/KWh starting from 8:00;
Rate 2: 0.50 $/KWh Starting from23:00, then:
During 8: 00~23:00 at a unit price of $1/Kwh.
During 23:00~8:00, at a unit price of $0.5/Kwh.
Default value: 0.86 KgCO2/KWh.
When the carbon emission unit is displayed, press and hold the [Set] button for 3 seconds to enter the
carbon emission setting.
Press [+] or [-] to select the setting value.
Press the [History] key to switch between digit positions.
Press the [OK] key to save the current settings and exit.
Carbon emission settings
4.Data Reset:
Press the [+] and [-] keys simultaneously for 3 seconds, and the display will flash,
Press the [Set] button again for 3 seconds to reset for factory setting and clear the data.
5.Technical parameters:
5.1 Display Range
Total power consumption time display range: 0 minutes, 0 seconds -9999 days
Power display range: 0.000-9999W
Voltage display range: 0.000-9999V
Current display range: 0.000-9999A
Power data display range: 0.000-9999KWh
5.2 Working conditions:
Working voltage: 230VAC/50HZ
Max current: 16A
Max power: 3680W
5.3 Warning:
For indoor use only and keep out of water!
Do not exceed the max power!
Total carbon emissions
14
General Description:
1.Real-Time Display
Press the [Energy] button repeatedly to display in sequence as following:
Power (W): Display real-time power.
AC Voltage(V)
Frequency(Hz)
Current(A)
Power factor: 1.00 means resistive load, < 1 means inductive load.
Maximum power: The maximum instantaneous power of overall
connection.
Maximum current: The maximum instantaneous current of overall
connection.
Overload alarm wattage: Defaults to 3680W. When the actual
power exceeds this value, "Overload" flashes.
How to DIY set the Overload alarm wattage?
When the overload alarm wattage is displayed, press and hold the [Energy] button for 3 seconds
to set the overload alarm value.
Press the [+] or [-] keys to adjust the number.
Press the [History] key to switch between digit positions.
Press the [OK] key to confirm and exit the settings.
Plug the power meter into a household 230 VAC wall-outlet, and connect with appliances such as
refrigerators, televisions, air conditioners, etc. or connect with microinverter Schuko plug into the
power meter. The power meter displays parameters such as power (watts), electricity consumption
(kilowatt hours), and electricity bill , and can visually display the electricity consumption/generation
for the past 7 days, 7 weeks, and 7 months.
OVERLOAD
TOTAL
2.Historical display
Press the [History] button repeatedly to display the electricity chart for the past 7 days, past 7 weeks,
and past 7 months.
Chart is only giving a brief and rough data; For precise-data Please take further view
When home applicant is connected to the Energy Meter, the data is showing the consumption data;
When the output of microinverter connected to the energy meter, the data is showing the generation
data
# Chart View
#Precise View
Long press and hold the [History] button for 3 seconds to display the precise value
Before Holding the [History] button for 3 seconds, check the display for Daily or Weekly or Monthly,
When enter precise view, accordingly the data will be for Daily or Weekly or Monthly.
Power Data in the past 7 days
When in Daily Data Chart, 1BAR=1KWh indicates that 1st horizontal line represents 0.1~1.0KWh,
and 2nd horizontal line represents 1.1~2.0KWh,etc…
Power Data in the past 7 weeks
When in Weekly Data Chart, 1BAR=3KWh represents 1st horizontal line representing 0.1~3KWh,
and 2nd horizontal line represents 3.1-6.0KWh displays two horizontal lines,etc…
Power Data in the past 7 months
When in Monthly Data Chart, 1BAR=10KWh represents 1st horizontal line representing 0.1~10KWh,
and 2nd horizontal line represents 10.1-20.0KWh displays two horizontal lines,etc…
Warning: For the purpose of safety, the Pre-set overload alarm wattage should be less than
3680W.
3.Cost and time display
Press the [Cost] button repeatedly to display in sequence:
Please refer to the second row on the display;
Clock: display the current time.
Press the [Set] button for 3 seconds to enter the clock setting.
Press the [+] or [-] keys to adjust the number.
Press the [History] key to switch between digit positions.
Press the [OK] key to complete the settings and exit.
Press the [History] and [Energy] buttons simultaneously for 3 seconds, and select the 12/24 hour
display.
Total power time
Display the total operating time when the power of the connected electrical appliance is greater than 1W.
Note: In the first hour, the second row displays: first 2 numbers to be minutes and second 2 numbers
to be seconds.
Afterwards, the second row displays: first 2 numbers to be hours and second 2 numbers to be minutes.
Total power data
Total cost/Income
Note: When the rate is equal to 0 or pending for preset, the data will not be included.
Rate display and settings
This machine has two modes: single rate/tariff and double rate/tariff.
32
TOTAL TIMETOTAL
Press the [+] or [-] keys to view the precise value of total electricity
consumption in the past 1-7 days/week/month.
TOTAL
TOTAL
TARIFF 1
TIME
TOTAL
COST

Popular Measuring Instrument manuals by other brands

Arrow Group Industries PENILASER P15C manual

Arrow Group Industries

Arrow Group Industries PENILASER P15C manual

Extech Instruments 382075 user guide

Extech Instruments

Extech Instruments 382075 user guide

Hy-Gain TAILTWISTER T-2X instruction manual

Hy-Gain

Hy-Gain TAILTWISTER T-2X instruction manual

Megger KF-LAB Mk II user guide

Megger

Megger KF-LAB Mk II user guide

Dwyer Instruments 89088 instruction manual

Dwyer Instruments

Dwyer Instruments 89088 instruction manual

Endress+Hauser Stamolys CA71NO operating instructions

Endress+Hauser

Endress+Hauser Stamolys CA71NO operating instructions

Wellis WIS user guide

Wellis

Wellis WIS user guide

Nokeval Solid-Sky-2Pro-24VDC manual

Nokeval

Nokeval Solid-Sky-2Pro-24VDC manual

Sperry instruments DSA660 operating instructions

Sperry instruments

Sperry instruments DSA660 operating instructions

FLIR EXTECH SDL310 user guide

FLIR

FLIR EXTECH SDL310 user guide

Fluke i30s instruction sheet

Fluke

Fluke i30s instruction sheet

Teledyne Lecroy PP006D Operator's manual

Teledyne Lecroy

Teledyne Lecroy PP006D Operator's manual

Toshiba GF642 manual

Toshiba

Toshiba GF642 manual

SEW 6213A-IN user manual

SEW

SEW 6213A-IN user manual

CG Products Peak & Hold manual

CG Products

CG Products Peak & Hold manual

C-Tech HTHY-8159 product manual

C-Tech

C-Tech HTHY-8159 product manual

Schmidt IL 30.0 Series Instructions for use

Schmidt

Schmidt IL 30.0 Series Instructions for use

Keithley 6485 instruction manual

Keithley

Keithley 6485 instruction manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.