Step 4: Clean Main Unit
Disconnect extension cord(s) from electrical outlet(s) & wipe with rag as
they are being wound up
Store on hanger in designated area
Wheel unit to locaon that has a drain & clean water hose
Pull discharge hose from clamp on front of machine, remove plug and
gently lay down to the drain
Remove clear round lid from the Dirty Soluon tank
Hose down interior of Dirty Soluon tank unl water runs clear
NOTE: PAY CAREFUL ATTENTION TO RINSE THE EXTERIOR OF
THE WIRE FLOAT CAGE LOCATED IN THE UPPER LEFT CORNER OF
THE TANK
Once the Dirty Soluon Tank is empty push discharge hose back into clamp
Wipe down exterior of unit & threads of Dirty Soluon tank lid
Store unit in designated area*
*When storing unit, it is recommended to leave discharge hose unplugged & lid to the Dirty
Solu�on tank offto allow interior of unit to dry out.
Weekly Maintenance:
Step 1: Lubricate Quick Disconnect
NOTE: ONLY USE A SILICONE SPRAY COMPATIBLE w/RUBBER
Spray the e inside of the female quick disconnect ng being sure
to coat the ball bearings & spin the collar
Spray the exterior of the male quick disconnect ng while pressing in
the middle pin
Repeatedly connect & disconnect the ngs together un male ng
‘pops out’ easily when disconnected (usually 3-4 mes is suient)
Step 2: Lubricate Trigger Valve
Spray Trigger Valve located in the ‘V’ between yellow ptrigger &
the boom of the handle
Gently work trigger to disperse lubricant
Step 3: Clean & lubricate any connec�ons where easy removal is desired
(For example)
Threads to Dirty Soluon tank lid
Soluon line connectors
Floor tool metal pipe to vacuum handle
Floor tool metal pipe secons
Vacuum head to pipe