TROUBLESHOOTING
IMPORTANT:Ifyourapplianceappearsnottobeoperatingcorrectly,turnofftheapplianceatthe
switchandthencontacttheServiceDepartment.
DONOTATTEMPTTOREPAIRTHEAPPLIANCEYOURSELF.
Theappliancemustbeaccessibleforaqualifiedpersontoperformanynecessaryrepair.
Toreplacetheglobe(220‐240VAC,10WE14),firstturntheapplianceoffandunplugfromthepowersource.
Removethedriptray.Pushtheclearcovertowardsthebackoftheapplianceandremove.Unscrewtheglobeand
replace.Alignthecoverwiththemountingandpullforwardtoclipinplace.Replacethedriptray.
6
PROBLEM POSSIBLECAUSE
Appliancedoesnotoperate. Notpluggedin.
Thecircuitbreakertrippedorablownfuse.
Compressorturnsonandoff
frequently.
Theroomtemperatureishotterthannormal.
Alargeamountoffoodhasbeenaddedtothefreezer.
Thedoorisopentoooften,ornotfullyclosed.
Thetemperaturecontrolisnotsetcorrectly.
Thedoorgasketdoesnotsealproperly.
Theappliancedoesnothavethecorrectclearances.
Theappliancehasrecentlybeendisconnectedforaperiodoftime.Fourhoursare
requiredfortheappliancetocooldowncompletely.
Temperatureinsidetheapplianceis
toowarm.
Temperaturecontrolissettoowarm.Turnthecontroltoacoolersettingandallow
severalhoursforthetemperaturetostabilize.
Dooriskeptopentoolongoropenedtoofrequently.Openthedoorless.
Thedoorisnotclosedcompletely.
Thedoorgasketdoesnotsealproperly.
Alargeamountofwarmorhotfoodmighthavebeenstoredrecently.Waituntilthe
appliancehashadachancetoreachitsselectedtemperature.
Theappliancehasrecentlybeendisconnectedforaperiodoftime.Fourhoursare
requiredfortheappliancetocooldowncompletely.
Temperatureinsidetheapplianceis
toocold.
Temperaturecontrolissettoocold.Turnthecontroltoawarmersettingandallow
severalhoursforthetemperaturetostabilize.
Poppingorcrackingsoundwhen
compressorcomeson.
Metalpartsundergoexpansionandcontraction,asinhotwaterpipes.Thisis
normal.Soundwillleveloffordisappearasfreezercontinuestorun.
Bubblingorgurglingsound,likewater
boiling.
Refrigerant(usedtocoolappliance)iscirculatingthroughoutthesystem.Thisis
normal.
Vibrations. Checktoassurethattheapplianceislevel.
Floorisunevenorweak.Appliancerocksonthefloorwhenitismovedslightly.Be
surefloorcanadequatelysupportappliance.Leveltheappliancebyadjustingthe
adjustablefeet.
Theapplianceistouchingthewall.Re‐leveltheapplianceandmoveitfromthewall.
See“InstallationInstructions”.
Moistureformsoninsidefreezer
walls.
Weatherishotandhumid,whichincreasesinternalrateoffrostbuild‐up.Thisis
normal.
Doorisslightlyopen.
Dooriskeptopentoolong,orisopenedtoofrequently.Openthedoorlessoften.
Thedoorisnotsealedproperly.
Moistureformsonoutsideof
appliance.
Doorisslightlyopen,causingcoldairfrominsidethefreezertomeetwarmmoistair
fromoutside.
Thedoorwillnotcloseproperly. Theapplianceisnotlevel.
Thegasketisdirty.