Omega DX 6635 User manual

0197


- Thank you for purchasing our DX6635 Talking Multi-Functional Ear and
Forehead thermometer For a desirable use of this product, be sure to read
this user Panual before XVH
- )LUVWO\Rpen WKHbattery case and gently pull out thHSODVWLFVDIHW\WDE
7KHWhermometer will not activateXQWLOWKHWDEKDVEHHQUHPRYHG
- For safe and proper use of this product, be sure to read and fuIly understand
Safety PrecautionsVWHSVRXWOLQHGLQWKLVuser Panual
- .HHSWKLVPDQXDOLQDVDIHDQGDFFHVVLEOHORFDWLRQIRUHDV\DFFHVVDQG
IXWXUHUHIHUHQFH
INTENDED FOR USE
The device is intended for the intermittent measurement and monitoring of
human body temperature by consumers in the home.
SAFETY PRECAUTIONS
- Warning marks and symbols are GLVSOD\HG for your safHW\ and WRHQVXUH
SURSHUXVHRIthis product DQGSUHYHQWDQ\LQMXULHV
- See table below for description of warning marks and symbols:
WARNING
Means a possibility of personal injury in case of improper use.
NOTICE
Means a possibility of personal injury or property damage in case
of improper use.
[*Property damage covers any damage to house,family property, domestic animal.]
MARKS OR SYMBOLS
PROHIBITION
MUST OBSERVE
IMPLICATION OF SYMBOL
Means Forbidden with detailed items expressed in words or figures
within or beside the mark. 7KHH[DPSOHKHUHLVGeneral Forbidden.
Means Obligatory with detailed items expressed in words or figures
within or beside the mark. 7KLVH[DPSOHKHUHLVGeneral compulsory.
Means Type-B device.
P.1

P.2

P.3

FRI
1st of the manufacturing year
P.4

P.5

3. Press and hold [ T ] button for 2 seconds to toggle the language
which you want or non talking function.
P.6

P.7

P.8

Maintenance:
1. Remove any stains on the body with a soft and dry cloth.
2. Don't wash with water or detergent containing abrasive or benzene.
Storage:
1. Clean the thermometer and XVHWKH cover to protect the lens after each use.
2. Don't leave the thermometer exposed to or at high risk of direct sunOLJKW,
high temperature, dampness, fire, flame, vibration or impact.
3. Remove the battery LIWKHGHYLFHZLOOQRWEHXVHGIRUDORQJSHULRGRIWLPH.
Calibration:
This thermometer is calibrated at the time of manufactured. If the
thermometer is used according to the instructionV, periodic recalibration is not
required. If at any time you question the accuracy of the measurement, please
contact the retailer immediately.
Don't attempt to modify or reassemble the thermometer.
MAINTENANCE, STORAGE AND CALIBRATION
TROUBLES AND TROUBLESHOOTING
Troubles
Battery symbol
on LCD
Check lists Countermeasures
“Lo” on screen
(result below
32.0℃ or 89.6℉)
“Hi” on screen
(result below
42.9℃ or 109.3℉)
No response/
Automatic
reset when pull
out insulator
/RZEattery SRZHU
Battery in wrong polarity
Poor battery contact
Change battery
Take out battery, reinsert
battery correctly
Low battery Change new battery
Thermometer rightly pointed
at the eardrum / forehead?
Follow user’s manual to
point at the eardrum /
forehead.
Please check the operation
method
Follow user’s manual for
proper measurement.
P.9

Product Name: Talking Multi-Functional Ear and Forehead thermometer
Model: DX6635
Power supply: DC3V (2 x AAA battery)
Power consumption: <30mA (for voice prompt)
Temperature sensing Part: IR sensor
Measuring range: 32.0℃ ~ 42.9℃ (89.6℉ ~109.3℉)
Room Temperature: 5.0℃ ~ 59.9℃ (41.0℉ ~139.8℉)
Measuring accuracy: +/- 0.2℃ (or +/- 0.4℉)
from 35.5℃ ~ 42.0℃ (or 95.9℉ ~107.6℉)
+/- 0.3℃ (+/- 0.5℉)
from 35.0℃ ~ 35.4℃ (or 89.6℉ ~ 95.8℉)
from 41.2℃ ~ 42.9℃ (or 107.7℉ ~ 109.3℉)
Room Temperature: +/- 1℃ (2℉)
Outer dimension: 130(L)x41(W)X57(D)mm
Weight : 54g (without batteries)
Working environment: 10℃~ 40℃ (50.0℉~104.0℉) For Ear
15℃~40℃ (59.0℉~104.0℉) For Forehead
Relative humidity: 20%RH~85%RH
Storage environment: -10℃~ 55℃ (14℉~131℉)
Relative humidity: 20%RH~85%RH
Precision/repeatability: +/- 0.3℃ (+/- 0.5℉)
*Dispose of used batteries with care consult your distribution center for details.
.
.
SPECIFICATION
P.10

0197
SYMBOLS
Batch code
Serial number
Attention: Read the operating Lnstructions EHforH use !
Applied part of type B
Disposal in accordance with Directive 2002/96/EC (WEEE)
LOT
SN
Complies with the European Medical Device Directive
(93/42/EEC) and amended by directive 2007/47/EC
requirements. Notified body TÜV Rheinland (CE0197)
The name and the address of the manufacturer
P.11

GUIDANCE AND MAUFACTU5ER'S DECLARATION
Emissions test Compliance Electromagnetic environment - guidance-
RF emissions
CISPR 11 Group2 The device must emit electromagnetic e
energy in order to perform its intended
function. Nearby electronic equipment may
be affected.
RF emissions
CISPR11
Class B
Harmonic
emissions
lEC 61000-3-2
Not applicable
Not applicable
RF emissions
CISPR 14-1
Complies
RF emissions
CISPR 15 Complies
The device is intended for use in the electromagnetic environment specified
below. The customer or the user assures that it is used in such an environment.
Guidance and manufacturer's declaration - electromagnetic emissions
The device is suitable for use in all
establishments other than domestic
and those directly connected to the
public low-voltage power supply network
that supplies buildings used for domestic
purposes.
Voltage
fluctuations /
flicker
emissions
lEC 61000-3-3
The device is not suitable for
interconnection with other equipment.
The device is not suitable for
interconnection with other equipment.
P.12

Immunity test IEC 60601
test level Compliance level
Electrostatic
discharge (ESD)
lEC 61000-4-2
±6 kV contact
±8 kV air
Electrical fast
transient/burst
IEC 61000-4-4
±2kV for power
supply lines
±1kV for input/
output lines
±1kV
differential
mode
±2kV
common mode
Voltage dips,
short
interruptions
and voltage
variations on
power supply
input lines
IEC 61000-4-11
The device is intended for use in the electromagnetic environment specified
below. The customer or the user should assure that it is used in such an
environment.
Guidance and manufacturer's declaration — electromagnetic immunity
Surge
IEC 61000-4-5
Electromagnetic
environment - guidance
±6 kV contact
±8 kV air
Floors should be wood,
concrete or ceramic tile.
If floors are covered with
synthetic material, the
relative humidity should
be at least 30 %.
Not applicable
Mains power quality
should be that of a typical
commercial or hospital
environment.
Not applicable
Mains power quality
should be that of a typical
commercial or hospital
environment.
<5% UT
(>95% dip in UT)
for 0.5 cycle
40% UT
(60% dip in UT)
for 5 Cycles
70% UT
(30% dip in UT)
for 25 Cycles
<5% UT
(>95% dip in UT)
for 5 sec
Mains power quality
should be that of a typical
commercial or hospital
environment. If the user
of the device requires
continued operation
during power mains
interruptions, it is
recommended that the
device is powered from
an uninterruptible power
supply or a battery.
Not applicable
Power frequency
(50/60Hz)
magnetic field
IEC 61000-4-8
3 A/m 3 A/m
Power frequency magnetic
fields should be at levels
characteristic of a typical
location in a typical
commercial or hospital
environment.
NOTE: UT is the a.c. mains voltage prior to application of the test level.
P.13

The device is intended for use in the electromagnetic environment specified
below. The customer or the user should assure that it is used in such an
environment.
Guidance and- manufacturer's declaration. Electromagnetic immunity
Conducted R
F lEC 61000-4-6
Portable and mobile RF
Communications equipment should be
used no closer to any part of the device,
including cables, than the recommended
separation distance calculated from the
equation applicable to the frequency of
the transmitter. Recommended
separation distance.
3 V
3 V/m
NOTE I At 80 MHz ends 800 MHz. the higher frequency range applies.
NOTE 2 These guidelines may not apply in all situations. Electromagnetic propagation
is affected by absorption and reflection from structures, objects and people.
3 Vrms
150 kHz to
80 MHz
Radiated RF lEC
61000-4-3
3 V/m
80 MHz to
2.5 GHz
80 MHz to 800 MHz
800 MHz to 2.5 GHz
Where P is the maximum output power
rating of the transmitter In watts (W)
according to the. Transmitter
manufacturer and d is the recommended
separation distance in meters (m).
Field strengths from fixed RF
transmitters, as determined by an
electromagnetic site survey,a should be
less than the compliance level in each
frequency range.
Interference may occur Ln the
vicinity of equipment marked
with the following symbol:
DField strengths from fixed transmitters, such as base stations for radio (cellular/
cordless) telephones and land mobile radios, amateur radio, AM and FM radio
broadcast and TV broadcast cannot be predicted theoretically with accuracy. To
d=[ ] p
3.5
V1
d=[ ] p
3.5
E1
d=[ ] p
7
E1
P.14

assess the electromagnetic environment due to fixed RF transmitters,
an electromagnetic site survey should be considered. If the measured
field strength in the location in which the device is used exceeds the
applicable RF compliance level above, should be observed to verify
normal operation. If abnormal performance is observed, additional
measures may be necessary, such as reorienting or relocating the
device.
b Over the frequency range 150 kHz to 80 MHz, field strengths should
be less than [Vi] V/m.
Recommended separation distances between portable and mobile RF
communications equipment and the device
Rated
maximum
transmitter
output power of
W
For transmitters rated at a maximum output power not listed above, the
recommended separation distance d in meters (m) can be estimated using the
equation applicable to the frequency of the transmitter, where P is the
maximum output power rating of the transmitter in watts (W) accordable to the
transmitter manufacturer.
NOTE 1 At 80 MHz and 800 MHz. the separation distance for the higher
frequency range applies.
150 kHz to 80 MHz
0,01
The device is intended for use in an electromagnetic environment in
which radiated RF disturbances are controlled. The customer or the user
of the device can help prevent electromagnetic interference by
maintaining a minimum distance between portable and mobile RF
communications equipment (transmitters) and the as recommended
below, according to the maximum output power of the communications
equipment.
Separation distance according to frequency of transmitter
150 kHz to 80 MHz 150 kHz to 80 MHz
0.12 0.12 0.23
0,1 0.38 0.38 0.73
1 1.2 1.2 2.3
10 3.8 3.8 7.3
100 12 12 23
d=[ ] p
3.5
V1 d=[ ] p
3.5
E1 d=[ ] p
7
E1
P.15

DECLARATION OF CONFORMITY
Shenzhen Dongdixin Technology Co., LTD declares that the DX6635
complies with following normative documents:
IEC60601-1, IEC60601-1-2, IEC60601-1-4, ASTM E1965-98,
ISO10993-5, ISO10993-10, ISO10993-1,ISO 14971,EN 12470-5.
NOTE 2 These guidelines may not apply in all situations. Electromagnetic
propagation is affected by absorption and reflection from structures, objects
and people.
For transmitters rated at a maximum output power not listed above, the
recommended separation distance d in meters (m) can be estimated using the
equation applicable to the frequency of the transmitter, where P is the maximum
output power rating of the transmitter in watts (W) accordable to the transmitter
manufacturer.
NOTE At 80 MHz and 800 MHz. the separation distance for the higher
frequency range applies.
NOTE These guidelines may not apply in all situations. Electromagnetic
propagation is affected by absorption and reflection from structures, objects
and people.
WARRANTY
Two-year warranty is available from purchasing date, excluding user-caused
failures listed below:
(1) Failure resulted in unauthorized disassembly and modification
(2) Failure resulted in unexpected drop during application or transportation
(3) Failure resulted in operation away from proper instruction in user’s manual.
Present the Warranty Card with seal of distribution center (incI. name and
address) for repair free.
P.16


Manufacturer:
Name: Shenzhen Dongdixin Technology Co., LTD.
Add: No.3 Building XiliBaimang Xusheng Industrial
Estate, 518108 Nanshan, Shenzhen ChinD
Copyright 2011 by Shenzhen Dongdixin Technology Co., LTD.
Edition: V1.2
Printed in 2011
Authorized EC-representative:
Shanghai International Holding Corp. GmbH (Europe)
Eiffestraße 80, 20537 Hamburg GeUPDQ\
0197
NOTES:
1) Under the environment with electrostatic discharge, the unit may
malfunction and may require user to reset the unit.
2) Dispose with care, please consult the retailer for details.
Other manuals for DX 6635
1
Table of contents
Other Omega Thermometer manuals

Omega
Omega OMEGASCOPE OS532 User manual

Omega
Omega HH11C User manual

Omega
Omega OS685L User manual

Omega
Omega HHM29-IR Supermeter Installation and operating instructions

Omega
Omega OS730K User manual

Omega
Omega OS950 Series User manual

Omega
Omega 865 User manual

Omega
Omega HH501DK User manual

Omega
Omega DP1001M User manual

Omega
Omega CL3515R User manual

Omega
Omega OMEGASCOPE OS520 User manual

Omega
Omega DP751 Series User manual

Omega
Omega HH501BT User manual

Omega
Omega HH501BE User manual

Omega
Omega TC-08 User manual

Omega
Omega OS541 User manual

Omega
Omega HH803U User manual

Omega
Omega OS758-LS User manual

Omega
Omega OMEGASCOPE OS520 User manual

Omega
Omega CL3512 User manual