Onko-CET SVIT User manual


HighTechnologyMedicalDevices 2|
Sreznevského17,83103Bratislava,Slovakia
Tel:+421244640977;Mobile:+421948610228,+421903114944;Mail:onkocet@onkocet.eu;Web:www.onkocet.eu
INSTRUCTIONFORUSE(User’sguide)
Contents
1.Generalguidelines.........................................................................................................................3
2.Utilization......................................................................................................................................3
3.Technicalspecifications..................................................................................................................3
4.Deliveryset....................................................................................................................................4
5.Devicestructureandoperationprinciples......................................................................................5
6.Safetymeasures.............................................................................................................................7
7.Setup.............................................................................................................................................7
8.Measurementprocedure................................................................................................................7
9.Technicalservice............................................................................................................................7
10.Troubleshooting.............................................................................................................................8
11.Packingandtransporting...............................................................................................................8
12.Storage..........................................................................................................................................8
13.Service&Warranty........................................................................................................................8
14.Warrantyclaim..............................................................................................................................9
Warrantycertificate.............................................................................................................................10
Acceptanceprotocol.............................................................................................................................11

HighTechnologyMedicalDevices 3|
Sreznevského17,83103Bratislava,Slovakia
Tel:+421244640977;Mobile:+421948610228,+421903114944;Mail:onkocet@onkocet.eu;Web:www.onkocet.eu
1. Generalguidelines
ThisOperatingmanual,includingspecifications,isauser’sguideforthecomputerinfraredimagingdevice
forexaminationsinreal‐time,modelTkVr‐IfP"SVIT"(hereafterreferringtoasInfraredcameraSVIT).
ReadthisOperatingmanualbeforeutilizingtheInfraredcameraSVIT.
2. Utilization
2.1.InfraredcameraSVITisintendedforobtainingofthethermalimageofpatients(thermogram)and
measurementofthetemperatureatanypointofthebodyofpatientwithoutthephysicalcontact
withhim/her.
Infraredcameraisusedin:oncology,therapy,urology,mammalogy,traumatology,angiologyand
otherregionsofmedicinefortheearly,preventivediagnosisofawholeseriesofdiseasesbefore
theappearanceofcomplaintsofpatientanddestructivechangesinthecloths
Infraredcameraisdevelopedwiththeuseoflatestachievementsinthetechnologyofthe
semiconductordetectorsofinfraredradiation.
Thedevicehasanumberofnewdiagnosticabilities.
2.2.Utilizationofthedeviceisabsolutelyharmlessforboththepatientsandmedicalpersonnel.
Thereforethemeasurementprocedurecanbeperformedrepeatedly.
Theresultsofmeasurementsaremappedontothescreenofpersonalcomputer,areprocessedby
softwareofthecameraandarememorized.
Theinfraredcameraisintendedforperformingexaminationsinhealthcentersandclinics.
2.3.TheinfraredcameraisdesignedinaccordancewithclimateconditionsofEUstandards,butshallbe
usedat22‐26Ctemperature,atmospherepressureof630‐800mmHgandrelativehumidityshall
notexceed80%.
2.4.Nooutsidesourcesofinfraredradiation(electricalheatinginstruments,incandescentlamps)canbe
presentinthediagnosticroom.Straightsunlightalsostronglyinfluencesthequalityoftheobtained
thermograms;thereforeblindsshouldbeinstalledonthewindows.

HighTechnologyMedicalDevices 4|
Sreznevského17,83103Bratislava,Slovakia
Tel:+421244640977;Mobile:+421948610228,+421903114944;Mail:onkocet@onkocet.eu;Web:www.onkocet.eu
3. TechnicalSpecifications
ThetechnicalspecificationsoftheSVITarethefollowing:
Rangeofthemeasurementofthetemperature 20
–
41°С
Sensitivity0,03
°
С(by the object temperatureof32°Сandthe
temperatureofsurroundingenvironment242°С)
Absoluteerrorofmeasurementofthetemperature ±0,25
°
С(atinstrument temperature24°С±2°С)
Spectralrange2,65
–
3,1 mkm
TypeofthedetectorCooledmatrix (InAs),dimensions:128х128elements
Opticalfieldofthesight18х18
FocusingManual
FrequencyframespersecondNotless than 50
InterfaceUSB2.0(HighSpeed)
RefrigerantLiquidnitrogen
TimeofoutputtooperatingconditionsNotmorethan15minutes
Timeofcontinuousoperationwiththesinglefilling
ofliquidnitrogen
Notlessthan12hour
RegimesofthemeasurementTheyaredeterminedbysoftware
RecordofthesinglethermogramsAquantityofwrittenthermogramsisdeterminedby
theaccessiblecapacityoftheharddriveofthe
computer
Recordofthethermo‐videosAquantityandthelengthofeachwrittenthermo‐film
isdeterminedbytheaccessiblecapacityofthehard
driveofthecomputer
ThedevicecomplieswiththerequirementsoftheEUstandards.
4. Deliveryset
Thedevicesetconsistsofthefollowingitems:
ItemQuantity Note
Thermal‐visioncamera1pc
SibThermSoftware 1pc
Pentium4typeandhigherlaptoporPC*1pc
Monitor*1pc
Keyboard*1pc
Printer*1pc
Mouse*1pc
Equipment
Connectingcable1pc
Tripodstand**1pc
Fillingfunnelofliquidnitrogen*1pc
Capacityforthefillingofliquidnitrogen*1pc
Operatingdocuments
Passport1pc
User‘sguide1pc
*Itissuppliedafteragreementwiththeuser
**Replacementbyanotherstand,intendedfortheequipmentwithmorethan4kgweight,isallowed

HighTechnologyMedicalDevices 5|
Sreznevského17,83103Bratislava,Slovakia
Tel:+421244640977;Mobile:+421948610228,+421903114944;Mail:onkocet@onkocet.eu;Web:www.onkocet.eu
5. DeviceStructureandoperationprinciples
Thedevicesetconsistsofthefollowingitems:
Infraredphotoreceiverdevice
Controllerofthephotoreceiverdevice
Moduleofworkingonthebaseofcomputer
Allmaterialbodieswiththetemperatureabove‐273Kemittheelectromagneticradiation,whichin
accordancetothePlanckformulacanbepresentedintheform,shownonFig.1(thedependenceofthe
emissionofphotonsonthewavelengthattwotemperaturesofblackbodyisshown).Withanincreaseinthe
temperatureofobjectsthenumberofemittedquantaofradiation(IR‐radiation)withthefixedwavelength
increases.Apuregainintheflowwithanincreaseinthetemperatureincreaseswiththedecreaseof
wavelengthandthereforeshort‐waverphotoreceiverwiththeregistrationofthethermalimageofobjectcan
giveaveryhigh‐contrastimage.Photoreceiverdevices,sensitiveintherangeof2,65‐3,1mkmareusedinthe
SVITthermalimagingsystem.
Fig.1.Dependenceofthedensityoftheflowofthequanta,
emittedbyblackbodyattwotemperatures,onthewavelength
Theemittedlightquanta,includinginvisible(infrared)withthewavelength>1mcmcanberegisteredbythesensorsof
infraredradiations.Thethermalimageofobjectsisformedwithspecialinfraredlensandisrecordedbythe
photosensitiveelementsofthematrix,establishedinthefocalplaneoflens.Theelementsoffocalmatrixconvertlight
quantaintotheelectriccharges,whicharereadbymultiplexer,arestrengthened,theyarepreliminarilyprocessedby
electroniccircuitandthentransferredtothecomputer.Asaresult,thethermal‐visionimageofobjectisreflectedonthe
screenofmonitor.Thesoftwareoftheinstrumentallowsexaminingofthetemperaturedistributionoverthesurfaceof
theskinofpatientandmeasuringofthetemperatureinanypointofimage.
ThetechniquesofdiagnosingofdiseasesisexplainedinDoctor’sManual.
ThefunctionaldiagramoftheinstrumentisshowninFig.2.Themeasurementofthedistributionoftemperatureoverthe
bodysurfaceofpatientisproducedwithoutanycontactofinstrumentwiththeskinofpatient.Instrumentmeasuresthe
naturalradiation,radiatedbypatient,fromdistance.

HighTechnologyMedicalDevices 6|
Sreznevského17,83103Bratislava,Slovakia
Tel:+421244640977;Mobile:+421948610228,+421903114944;Mail:onkocet@onkocet.eu;Web:www.onkocet.eu
FunctionalschemeofSVIT
Fig.2.Thesimplifiedschemeofthecompletedeviceset
1‐lens,2‐thecalibrationdevice,3‐colddiaphragm,4‐matrix[FPU],5‐vacuumcryostatwiththeclear
window,6‐generatorofthemanagersofpulseandconstantstresses,7‐amplifierwiththedifferential
output,8‐temperaturegauge[FPU]‐theautomaticweaponoftheswitchingonofthebiasvoltageoftheInAs
baselayer,9,14‐unitsforcontrolandsynchronization,10‐ACP,11‐adder,12‐dispatcherofmemory,13,16‐
memorybanks,15‐unitofconnectiontothecomputer,17‐thecomputer
Thethermalradiationoftheobservedsceneisfocusedbylens(1)tothematrixofhybridmicrocircuit(4),
establishedinthevacuumcryostat(5).Thelevelofbackgroundgatingislimitedbycolddiaphragm(3).All
constantandsurgevoltagesnecessaryfortheworkofphotoreceiverdeviceareassignedbygenerator(6).
Thedeviceofcalibrationconsistsoftwomobileshutters(specularandblack),controlledbyelectromagnets.
Electromagnetsaregovernedbytheblock(9),whichalsotransfersintotheblock(14)thepulses,which
synchronizetheworkofATsP(10),adder(11),USBconnectionunitviaUSBport(15)andblockofthe
transmissionofinformationaboutthestateofautomate(8).Signalfromthematrixphotoreceiverdevicewill
begiventotheentranceofamplifier(7).Theamplifiedusefulsignalistransferredtothepersonalcomputer
afterprocessinginthecontroller(1016).
Onthehousingofinfraredcamerathereare:theringofimagefocusing,USB2.0portfortheconnectiontothe
computer,connectorforsynchronization(7‐pinconnector)andfasteningfortheinstallationofcameratothe
stand.Theindicatorofthereadinessofinstrumentfortheworkisinstalledneartheneckofcryostat.

HighTechnologyMedicalDevices 7|
Sreznevského17,83103Bratislava,Slovakia
Tel:+421244640977;Mobile:+421948610228,+421903114944;Mail:onkocet@onkocet.eu;Web:www.onkocet.eu
6. Safetymeasures
TheInfraredcameraSVITcomplieswiththerequirementsoftheEUstandards.Thesafetymeasuresfor
InfraredcameraSVITaresimilartothegeneralsafetymeasuresforanyelectronics.TheInfraredcameraSVIT
isgroundedbycontactingsolderpadsthatareinthetwo‐pinplug.Devicesconnectedtotheinfraredcamera
SVIT(printer)mustcomplywiththerequirementsoftheEUstandards.
Theinfraredcameramustbeconnectedtothepowersupplybytripolarseparatedsockets.
7. Setup
TheinfraredcameraSVITmustbeusedindoorsandallclimaticrequirementsdefinedinOperatingmanual
mustbemet.TheinfraredcameraSVITistransportedinaplasticbox.Thedevicemustbeunpackedindoorsat
roomtemperature.
7.1. Opentheboxandtakeoffthepolyethylenecoverfromthecamera.
7.2. Fastenthermal‐visioncameratothestand.
7.3. ConnectthecameratothecomputerbythestandardUSB2.0cable.
7.4. Fillthecryostatwithliquidnitrogen.
7.5. Startthecomputer.
7.6. StarttheSibThermsoftware.
7.7. Beginthemeasurements(inaccordancewiththeinstructionsfortheinstrument)
7.8. Attheendofmeasurementsdisconnecttheinstrument(afterturningofftheinstrument,closethe
SibThermsoftwareandturnoffthecomputerbystandardmeans.
8. Measurementprocedure
Forconductingofthemeasurementstheinfraredcameraisdirectedtopatient.Thecontactofpatientwith
thecameraisnotrequired.Thedistancebetweenthecameraandthepatientisdeterminedbythesizeof
region,whichisgoingtobevisualizedonthethermogram.
Aftertheappearanceofanimage,bytherotationofthefocusring,whichislocatedunderthedevicelens(in
thefrontsectionoftheinstrument),itisnecessarytofocusimagetobecomesharp.
Controlofinfraredcameraandconductingofmeasurementsiscarriedoutthroughthedialoguewiththe
SibThermsoftware.
9. Maintenance
Maintenanceshallbecarriedoutinordertopreventdamages.ReadSafetyMeasuressectionofPassport
beforecarryingoutmaintenance.
Followingmaintenancetypesarerequired:
Day‐to‐daymaintenanceisperformedbymedicalpersonnelaccordingtosection7;
Annualmaintenanceisperformedbytechnicalpersonnelonceayear.
Annualmaintenanceincludesexaminingofcameraunits,andtechnicalconditionofcamera.
Incaseofmalfunction,thedeviceisrepairedbyrepresentativesofthemanufacturer.

HighTechnologyMedicalDevices 8|
Sreznevského17,83103Bratislava,Slovakia
Tel:+421244640977;Mobile:+421948610228,+421903114944;Mail:onkocet@onkocet.eu;Web:www.onkocet.eu
10. Troubleshooting
Possibleproblemsinclude:
№ ProblemResolving
1SibThermsoftwareshowsanerroranddoes
notwork
RebootSibThermsoftware
2ThethermogramiswrongCheckcoolant,lenscover,ambienttemperature,
USBconnection,systempowersupply.
Makeacalibrationprocess.Checkthedevicedriver.
3FramerateislowDisableinterpolation.
Type1asaccumulationparameter
4SibThermsoftwareisnotexecutedCheckSibTherm.exefilepath.
Whenotherproblemsoccur,contacttherepresentantofthemanufacturer.
11. Packingandtransporting
Fordeliverythecameraispackedintoapolyethylenefilmandbox.
Thedocumentationispackedintopolyethylenefilmandincludedintheboxwiththedevice.
Thecameracanbetransportedbyanyflighttransportexcludingnon‐heatedairplanesections,climatic
conditionsmustcorrespondtotheEUstandards.
12. Storage
Forshorttermtheinfraredcameramustbestoredindoorsat10‐35°Ctemperature,andrelativehumidity
mustbe80%(percent)attemperatureof25°C.
Forlongtermtheinfraredcameramustbestoredatawarehouseofthemanufacturerorcustomerin
accordancewithstorageconditionsoftheEUstandards.
13. Service&Warranty
ThemanufacturerguaranteesthattheInfraredcameraSVITcorrespondstoindicatedspecificationswhenall
conditionsanduse,maintenance,transportingandstoringrequirementsindicatedinthedevicedocuments
aremet.
Thewarrantyperiodis24months,itbeginsoncetheAcceptanceprotocolissigned.
Thewarrantyserviceiscarriedoutbyarepresentantofthemanufactureratnocosttothecustomer.Ifthe
cameraisdamagedasaresultofwrongusageofthedevice,thewarrantyserviceiscarriedoutbythe
representantofthemanufactureratcustomer´scost.

HighTechnologyMedicalDevices 9|
Sreznevského17,83103Bratislava,Slovakia
Tel:+421244640977;Mobile:+421948610228,+421903114944;Mail:onkocet@onkocet.eu;Web:www.onkocet.eu
14. Warrantyclaim
Allwarrantyclaimsmustbefilledinthefollowingform:
Initialdateofusage
(dateofsigningofthe
acceptanceprotocol)
Problemappearance
Data
ProblemBriefDescriptionComments

HighTechnologyMedicalDevices 10|
Sreznevského17,83103Bratislava,Slovakia
Tel:+421244640977;Mobile:+421948610228,+421903114944;Mail:onkocet@onkocet.eu;Web:www.onkocet.eu
ONKOCETs.r.o.,Kutuzovova4,90201Pezinok,Slovakia
WARRANTYCERTIFICATE
forrepair(change)withinthewarrantyterm
Medicaldevice‐InfraredcameraSVIT
Numberandproductiondata________________________________________________
Purchased_________________________________________________________________
(data,signatureandstampofseller)
Setinoperation_______________________________________________________
(date,signature)
Acceptedforwarranty__________________________________________
(date,signature,malfunctiondescription)
Thestatementoftherepresentativeofthemanufacturer:________________________________________________
___________________________________________________________________________________________________
___________________________________________________________________________________________________
___________________________________________________________________________________________________
_______________________________________________________________________________________________
(date,signature,statement)

HighTechnologyMedicalDevices 11|
Sreznevského17,83103Bratislava,Slovakia
Tel:+421244640977;Mobile:+421948610228,+421903114944;Mail:onkocet@onkocet.eu;Web:www.onkocet.eu
Acceptanceprotocol
TheInfraredcameraSVIT,factory#_______________________complieswiththetechnicalrequirements,contains
acompletesetofaccessoriesandisserviceable.
Warrantyperiodis24months,itbeginsoncethisacceptanceprotocolissigned.
Date:_______________________
______________________________ ________________________
(signatureandstampofseller) (nameofseller)
______________________________ ________________________
(signatureofbuyer) (nameofbuyer)
Table of contents