hy5t
Far side
ON
OFF
Near side
←Hysteresis
hy5t
(7) The present maximum blinks.
Use the [+] or [−] key to enter
the distance at which to
generate the maximum analog
output. 3.000
10V
e.g.) Analog voltage output type
■This completes the setup.
0.234
Model name Maximum (10V/20mA)
CD22-15x 5.000 mm
CD22-35x 15.000 mm
CD22-100x 50.00 mm
<Reference> Default maximum values
As an example, the value is set to
[3.000] here.
At a distance of [3.000], the
maximum analog output ([10V] or
[20mA]) is generated.
(8) Enter the distance and press [SET].
The maximum is confirmed, and the
sensor returns to the previous screen.
10V 20mA
Press [ZERO RUN] to return
the sensor to [RUN] mode.
FG52 FGS2 teach
Place the object and
execute FGS2 teach to set
the detection range around
the object. (Two thresholds
are set, one before and one
after the object, and the
output turns OFF when the
measurement distance is
within this range.)
1Pt 1-point teach
Teach is executed for one
position: without the object
present (that is, just the
background is detected).
Then, the output turns ON
when the measurement
distance is closer than that
position.
(Excluding the dead zone in
front of the sensor.)
←Hysteresis
Object
ON
OFF
← →
FGS2 teach features
ON
OFF
Dead zone
←Hysteresis
Back
ground
Setting the control output
thresholds
(the switching references)
Use teach mode to set the thresholds used as the references for
switching control output ON and OFF.
To match different applications, the following three modes are available.
• 2-point teach
• 1-point teach
• FGS2 teach
Teach is executed with the
object at two positions: the
near and far points in
relation to the sensor. Then,
output turns ON when the
measurement distance is
between these positions.
2-point teach
2Pt
2
Output range differences
depending on the teach mode
Value entered in step (4) is
larger
Value entered in step (7) is
larger
Analog output
Approx.
15V/appr
ox. 24mA
10V/20mA
0V/4mA
Distance
Analog output
Approx.
15V/approx.
24mA
10V/20mA
0V/4mA
Distance
As shown below, the directions in which analog output increases and
decreases vary depending on which of the values entered in steps (4) and (7)
is larger.
The maximum analog output is
generated at the far side.
The maximum analog output is
generated at the near side.
Directions for increasing and
decreasing analog output
10V
e.g.) Analog voltage output type
0V
e.g.) Analog voltage output type
(5) Enter the distance and press [SET].
The minimum is confirmed, and the
sensor returns to the previous screen.
0V 4mA
(6) Set the maximum.
Press the [+] key to display the
maximum analog output. Press
[SET].
10V 20mA
hy5t →
• Voltage output
type: [0V]
• Current output type:
[4mA]
• Voltage output
type: [10V]
• Current output type:
[20mA]
• Voltage output
type: [10V]
• Current output type:
[20mA]
The sensor receives light from the background
(such as a white conveyor belt) at all times and
activates when this light is blocked by the
object, so detection is also possible when the
sensor can no longer receive light.
This is the optimal mode for conventionally hard
to detect objects such as thin black objects,
glossy metal, and objects with rough surfaces.
* FGS2 teach requires a stable background
such as a conveyor belt.
Settable
with the
hysteresis
→
Settable
with the
hysteresis
→
Settable
with the
hysteresis