Bosean Electronic Technology BH-4S User manual

BH-4S
Portable Multi-gas Detector
User Manual
Ver:BSA20150424001
Bosean Electronic Technology Co.,Ltd
ISO9001-2008

Bosean Electronic Technology Co.,Ltd www.bosean.com
Tel:86-371-86533226 Email: sales03@bosean.com
- 1 -
Brief Introduction
BH-4S portable multi-gas
detector could detect
combustible gas, O2 and other
two types toxic gases
continuously and simultaneously.
It is widely used in the area
where explosion-proof is required
or toxic gas leaks, like
underground channels or mining
industry, so as to protect the
workers’ life and avoid damage
on the relevant equipments.
1. Main features
*Natural diffusion sampling method and high-sensitivity sensor,
with high sensitivity and repeatability.
* 32-bit built-in MCU, high reliability and self-adaptation ability.
* Full functions, easy operation.
* CSTN colorful LCD, more intuitionistic, abundant and clear
indication.
* Compact design, easy carrying.
* High strength engineering plastics and compound anti-slippery
rubber; high strength, water-proof, dust-proof and explosion-proof.

Bosean Electronic Technology Co.,Ltd www.bosean.com
Tel:86-371-86533226 Email: sales03@bosean.com
- 2 -
2. Structure & Function
2.1 Appearance
Fig. A
2.2 Detector structure: the main shell, circuit boards, batteries,
display, sensors, chargers of the components.
2.3 Principle: Electrochemical and Catalytic sensor.
3. Technical Data
Target Gas
Range
Low alarm
High alarm
Resolution
LEL
0~100%LEL
20%LEL
50%LEL
1%LEL
H2S
0~100ppm
10ppm
35ppm
1ppm
CO
0~999ppm
50ppm
150ppm
1ppm
O2
0~30%vol
19.5%vol
23.5%vol
0.1%vol
Other gases needed, please contact supplier
Gas sampling method: Natural diffusion
Detecting gas: Combustible gas, H2S, CO, O2
No.
Name
No.
Name
1
Alarm light
4
Buzzer
2
Button
5
Sensors
3
LCD screen

Bosean Electronic Technology Co.,Ltd www.bosean.com
Tel:86-371-86533226 Email: sales03@bosean.com
- 3 -
Accuracy: ≤±5% F.S.
Response Time: ≤30s
Indication: LCD displays real-time and system status;
LED, audio and vibration alert for gas leakage, fault and low
voltage.
Working environment: -20℃~50℃,<95%RH (no dew)
Power Source: DC3.7V Li-on battery, 2000mAh
Charging time: 6h~8h
Working time: ≥ 8h continuously (without alarming)
Gas Sensor Life: 2 years
Explosion-proof grade: Ex ib IIB T3 Gb
Protection Grade: IP65
Weight: Appr. 400g (with battery)
Dimensions: 130mm×67mm×30mm(L × W × H)
4. Operation & Function
4.1 Turn on
Press the button for 3s and then release it. After the buzzer
gives short sound once, the detector is turned on. After 10
seconds, it enters detecting status. At this time, it displays the
concentration of O2, H2S, CO and Combustible gas in the
environment as figure 1.
Fig.1

Bosean Electronic Technology Co.,Ltd www.bosean.com
Tel:86-371-86533226 Email: sales03@bosean.com
- 4 -
4.2 Turn off
Under power on status, press button for more than 3s, With
the buzzer issued a "beep" sound, the LCD screen prompts the
user to shut down the interface shown in Figure 2, the user
through the ▲▼keys to select whether to shut down, if you
choose to shut down, the screen no longer display any information,
the detector into the shutdown state.
Fig. 2
4.3 Button function
Detector in the normal detection state as shown in Figure 3:
Fig. 3
21:18:04
40%
SHUT DOWN
YES NO

Bosean Electronic Technology Co.,Ltd www.bosean.com
Tel:86-371-86533226 Email: sales03@bosean.com
- 5 -
Press any key to open the back light (user can set back light time)
Press " " key to enter the menu;
Press "▲" key to enter the alarm record;
press "▲ ▼" key to select the alarm log to view the alarm record
details.
Press "▼" key to enter the gas concentration curve display
interface;
press "▲ ▼" key to view the different gas type concentration
value curve.
4.3.1 When the detector detects the gas concentration is lower
than the pre-set low alarm value (Note: when the concentration of
oxygen is higher than the low alarm value and lower than the high
alarm value), the detector is in the normal state, No alarm at this
state.
4.3.2 When the detected gas concentration is higher than the
preset low alarm value and less than the high alarm value (Note:
when the oxygen concentration is lower than the low alarm value),
the detector is in a low alarm state, the buzzer sends out every 1s
"beep, beep" alarm sound, the red light flashes synchronously,
and the gas concentration value on the screen changes the color
to yellow, the back light and the vibrator are also open, indicate
low alarm; press " " key to mute, but still shows the alarm
information. Until the new alarm is triggered, the buzzer is
resumed and the alarm light, the vibrator are restored. When the
detector detects the gas concentration value below the low alarm
value, the gas concentration value color turns green, the alarm
signal will be released automatically. Alarming state shown in
Figure 4.

Bosean Electronic Technology Co.,Ltd www.bosean.com
Tel:86-371-86533226 Email: sales03@bosean.com
- 6 -
Fig. 4
4.3.3 When the detected gas concentration is higher than the
pre-set high alarm value, the detector is in the high alarm state,
then the buzzer sends every 1s "Di Di Di Di, ... Di Di Di Di" And the
red indicator light flashes synchronously, the change of the gas
concentration value is displayed on the screen. The color
becomes red, the back light and the vibrator are also on, indicate
high alarm; press " " key to mute, but still Display alarm
information. Until the new alarm is triggered, the buzzer is
resumed and the alarm light, the vibrator are restored. When the
detector detects the gas concentration value below the low alarm
value, the gas concentration value color turns green, the alarm
signal will be automatically released. the alarm signal will be
released automatically. Alarming state shown in Figure 5.
Fig 5.

Bosean Electronic Technology Co.,Ltd www.bosean.com
Tel:86-371-86533226 Email: sales03@bosean.com
- 7 -
4.3.4 When the detected gas concentration is higher than the test
range, the buzzer sounds "beep, beep", the LCD screen is on, the
vibrator is on, and the screen Display the maximum range of gas,
indicating over range. Press the " " key to release the alarm.
4. 3.5 Normal monitoring interface under the first line shows the
time, alarm signs ( it occurs when there is alarm, yellow color
with low alarm, red color with high alarm), the buzzer instructions
(normal , mute ), battery percentage, battery power, date and
temperature,
Note: The alarm sound above can be manually cleared by
pressing the " " key. After clearing, the alarm information is still
displayed normally. If the alarm is triggered again, the
corresponding alarm sound information can be issued again.
4.4 Use and set functions
The detector has a total of alarm record function, gas
concentration curve display, gas parameters setting, calibration,
zero calibration, language settings, information viewing, back light
settings, time settings and other functions. Press the " " button
to enter the function selection, in the function selection interface to
move the cursor to “return” words, continue to press " " to
return to the normal monitoring interface as shown in Figure 6.
Fig. 6

Bosean Electronic Technology Co.,Ltd www.bosean.com
Tel:86-371-86533226 Email: sales03@bosean.com
- 8 -
4.4.1 Alarm record and alarm curve
a. Alarm record function:
Detector in the normal detection of the main interface, press ▲to
enter the alarm recording interface, the record includes the alarm
sensor name, alarm type, alarm value, alarm time. As shown in
Figure 7: This feature can view the gas alarm history, easy
checking.
As shown in the following table:
Sensor
Type
Value
No.
Remark
O2
↑(H)
30
1/4(Current/Total)
Ex
↑(H)
80
2/4(Current/Total)
H2S
↑(H)
58
3/4(Current/Total)
CO
↓(L)
127
4/4(Current/Total)
2016-06-16 12:15:35 Alarm time
The alarm log value is the maximum alarm value in the alarm
interval (O2 is the lowest). The maximum number of record groups
is 500.
b. Curve display function:
The detector in the normal detection of the main interface, press
the ▼to enter the curve display interface, this time through the
▲ ▼ button to view each channel sensor gas concentration
curve. Each channel sensor has a curve display.
Oxygen as an example:

Bosean Electronic Technology Co.,Ltd www.bosean.com
Tel:86-371-86533226 Email: sales03@bosean.com
- 9 -
Fig.7
Description
The abscissa X axis is the time,
the current record within 9s of
the curve
The vertical axis Y is the sensor
value, data of the sensor can be
seen from the Y axis
Note: the axis and the data is green, the data curve is blue, the
low alarm line is yellow, high alarm line is red.
4.4.2 Detector menu settings
In the normal detection mode, press " " key to enter the menu,
then press ▲ ▼ key to select the setting of gas parameters,
calibration, calibration zero, language settings, information view,
back light settings, time setting function. These function menus
can be displayed cyclically and can be selected by cursor
movement.
The menu function is as follows:
Description
Operation
Return
Press ▲▼key to move the cursor to the
return function, press " " to return to the main
interface.
Setting
Four sensor parameters can be set, including
the gas type, unit selection, high alarm and low
alarm, range settings.
Calibration
Can be calibrated for the sensors
Zero
Zero calibration

Bosean Electronic Technology Co.,Ltd www.bosean.com
Tel:86-371-86533226 Email: sales03@bosean.com
- 10 -
Language
Choose language
Information
Soft version and date of manufacture
Back light
Setting the time of back light
Time set
Set the date and the time
4.4.3 Parameter setting of the detector
Display
Description
Fig.8 Fig.9
1. Move the cursor to set and press " " to
enter set interface, input four passwords, as
shown in Figure 8, the user can press " " to
move the cursor, input the password by ▲ ▼
key, sensor parameters as shown in Figure 9.
Fig.10 Fig.11
2. Gas parameters setting
Parameter settings include gas type, unit
select, high alarm and low alarm, range
settings. As an example with Ex, as shown in
Figure 10, use the ▲▼key to select the gas
type (Ex),press the to enter Ex gas
parameter settings, As shown in Figure 11,
use the▲▼key to modify the parameter, after
done, press the return.
If no special requirements, alarm value
parameters should not be modified.

Bosean Electronic Technology Co.,Ltd www.bosean.com
Tel:86-371-86533226 Email: sales03@bosean.com
- 11 -
Fig. 12
Fig. 13
Fig. 14
3. Zero Calibration
In the menu function interface, select the Zero,
press" " key to enter the password
interface shown in Figure 12, input the correct
password, the same need to select the zero
gas type, still with Ex as an example shown in
Figure 13, Press the " " key to move the
cursor, use the ▲▼key to modify the zero
parameter value, as shown in Figure 14,
modify the cursor to move to the last press the
▼key to return to the previous menu.
Warning: 1. zero calibration, please ensure
make it in the clean air, otherwise will affect
the accuracy of gas detector.
2. the detector have been made calibration
with standard gas in factory, the user should
not operate this.
Fig.15
4. Language
In the menu function interface, select the
language, press the " " key, you can see
the interface shown in Figure 15, through the
▲ ▼ key to move the cursor to select
language.
Fig.16
5. Information
In the menu function interface, select the
information, press the " " key, you can see
the product information shown in Figure 16,
including software version, factory date.

Bosean Electronic Technology Co.,Ltd www.bosean.com
Tel:86-371-86533226 Email: sales03@bosean.com
- 12 -
Fig.17
6. Back light
In the menu function interface, select the light,
enter the back light settings interface as
shown in Figure 17, press the " " key to
move the cursor, use the ▲ ▼ key to set the
seconds, the maximum can be set to 60S.
Fig. 18
7. Time set
In the menu function interface, select the time,
enter it as shown in the figure 18, press the
" " key to move the cursor, use the▲▼key
to set the current system time, press the▼key
return to the main menu.
4.4.4. Alarm information
The following table shows the details of each alarm:
Alarm type
Display
Low alarm:
Slowly tweak the alarm tone
The alarm indication is yellow
The red alarm light flashes
vibrating
High alarm:
Abnormal harsh tone of the drop alarm
sound
The alarm indication is red
The red alarm light flashes
vibrating

Bosean Electronic Technology Co.,Ltd www.bosean.com
Tel:86-371-86533226 Email: sales03@bosean.com
- 13 -
4.5. Charging
Please charge the detector when it shows low battery or the
detector can’t be turned on due to low battery. Before charging,
please turn off the detector. After you connect the charger correctly
between the detector and AC power source, the detector will be
turned on automatically. When the battery mark on the screen is
full and doesn’t change any more, it means the charging is
completed. Please pull off the charger.
Warning: During charging status, the detector can’t detect the gas
leakage. Please do not try to charge it at testing places to avoid
fire or explosion. Please do not charge it when the detector is
working to avoid potential damage.
Note: Make sure full charge for at least once within 3 months
since production date.
5. Possible fault and corresponding solution
Possible fault
Possible reason
Corresponding solution
The detector
can’t be turned
on
Too low battery
Please charge it in time.
The detector dies
Please contact the
manufacturer of dealer
Fault of electric
circuit
Please contact the
manufacturer of dealer
No response to
the gas
Warm up is not
finished
Wait till warm up is
finished
Fault of electric
circuit
Please contact the
manufacturer of dealer

Bosean Electronic Technology Co.,Ltd www.bosean.com
Tel:86-371-86533226 Email: sales03@bosean.com
- 14 -
Inaccurate
indication
Sensor is overdue
Please contact the
manufacturer or dealer to
replace the gas senor
Uncalibrated for long
time
Please calibrate it in time
Fault indication
of time
Battery voltage is
used up
Please charge it and reset
time
Strong
electromagnetism
disturb
Please reset time
Zero calibration
is unavailable
Too much zero drift
of gas sensor
Please calibrate or
replace the gas sensor
Minus gas level
displayed
Gas sensor drift
Calibrate zero point
Sensor fault
indication
Sensor fault
Please contact the
manufacturer or dealer to
replace the gas senor
6. Notices
6.1 Falling down from high places or strong shake is prohibited.
6.2 The detector may not work properly at interferential
high-concentration gas.
6.3 To avoid incorrect result or possible damage to the detector,
please operate and handle the detector in accordance with the
manual.
6.4 The detector should be not stored or used neither under the
circumstance with caustic gas (such as Cl2), nor under the other
rugged circumstances, including excessive high or low
temperature, high humidity, electromagnetic field and strong

Bosean Electronic Technology Co.,Ltd www.bosean.com
Tel:86-371-86533226 Email: sales03@bosean.com
- 15 -
sunshine.
6.5 If there is dust on the surface of the detector after a long-term
use, please clean it lightly with clean soft cloth. The surface may
be scraped or destroyed with caustic solvent or hard things.
6.6 To assure the testing accuracy, the detector should be
calibrated periodically. And the calibration period should be less
than one year.
6.7 Please put the used Lithium batteries to the appointed places
or send to our company. Don’t discard them into the dustbin at
random.
7. Standard accessories:
Suit case packaging 1pc
Charger 1pc
Calibration cap 1pc
Communications cable 1pc
User manual 1pc
Henan Bosean Electronic Technology Co.,Ltd.
No.228,West 4th Ring,National High-Tech zone,Zhengzhou,China
Tel: +86 371 86533226
Fax: +86 371 86533226
E-mail: sales03@bosean.com
Website: www.bosean.com
Table of contents
Popular Security Sensor manuals by other brands

no-flame
no-flame 83197 instruction manual

AFRISO
AFRISO Eurovac HV operating instructions

Sperian
Sperian Biosystems NXP Reference manual

Redwall
Redwall LRP3020 Installation instruction

jablotron
jablotron JA-160PC quick start guide

PCB Piezotronics
PCB Piezotronics 4115K-07A Installation and operating manual