manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Siemens
  6. •
  7. Security Sensor
  8. •
  9. Siemens FDT181 User manual

Siemens FDT181 User manual

Other Siemens Security Sensor manuals

Siemens FDT421 User manual

Siemens

Siemens FDT421 User manual

Siemens Matchtec IRM270C User manual

Siemens

Siemens Matchtec IRM270C User manual

Siemens Sinteso FD20 Instruction Manual

Siemens

Siemens Sinteso FD20 Instruction Manual

Siemens FDOOT441 User manual

Siemens

Siemens FDOOT441 User manual

Siemens 5SV60 MC Series User manual

Siemens

Siemens 5SV60 MC Series User manual

Siemens FDL241-9 Quick start guide

Siemens

Siemens FDL241-9 Quick start guide

Siemens 5SM6 01 2 Series User manual

Siemens

Siemens 5SM6 01 2 Series User manual

Siemens FDOOT271 User manual

Siemens

Siemens FDOOT271 User manual

Siemens DELTA i-system 1,1 Komfort 5TC1 505 User manual

Siemens

Siemens DELTA i-system 1,1 Komfort 5TC1 505 User manual

Siemens ADM-Q12 User manual

Siemens

Siemens ADM-Q12 User manual

Siemens DELTA iris 5TG5930-2 Series User manual

Siemens

Siemens DELTA iris 5TG5930-2 Series User manual

Siemens FS720 Series User manual

Siemens

Siemens FS720 Series User manual

Siemens QRI Series User manual

Siemens

Siemens QRI Series User manual

Siemens FDB22 Series User manual

Siemens

Siemens FDB22 Series User manual

Siemens DB721 User manual

Siemens

Siemens DB721 User manual

Siemens SA-3I User manual

Siemens

Siemens SA-3I User manual

Siemens DELTA reflex 5TC7 2 Series Service manual

Siemens

Siemens DELTA reflex 5TC7 2 Series Service manual

Siemens FDT181C User manual

Siemens

Siemens FDT181C User manual

Siemens 5TC1585 User manual

Siemens

Siemens 5TC1585 User manual

Siemens UP 258D11 OPTISENS OFFICE User manual

Siemens

Siemens UP 258D11 OPTISENS OFFICE User manual

Siemens 5TC1700 User manual

Siemens

Siemens 5TC1700 User manual

Siemens SIMATIC ET 200S User manual

Siemens

Siemens SIMATIC ET 200S User manual

Siemens DB110 User manual

Siemens

Siemens DB110 User manual

Siemens CEREBRUS PYROTRONICS AD-3XRI User manual

Siemens

Siemens CEREBRUS PYROTRONICS AD-3XRI User manual

Popular Security Sensor manuals by other brands

Honeywell Home PROSiXCOCN Installation and setup guide

Honeywell Home

Honeywell Home PROSiXCOCN Installation and setup guide

Duevi SIRPZ-RB-868 Operation

Duevi

Duevi SIRPZ-RB-868 Operation

RKI 65-2483RK Operator's manual

RKI

RKI 65-2483RK Operator's manual

Nortech PD160 Enhanced Series user manual

Nortech

Nortech PD160 Enhanced Series user manual

Omron K8AC-H2 manual

Omron

Omron K8AC-H2 manual

Agilent Technologies G8610 Series Quick reference card

Agilent Technologies

Agilent Technologies G8610 Series Quick reference card

Shinko SE2EA-1-0-0 instruction manual

Shinko

Shinko SE2EA-1-0-0 instruction manual

Det-Tronics X Series instructions

Det-Tronics

Det-Tronics X Series instructions

ACR Electronics COBHAM RCL-300A Product support manual

ACR Electronics

ACR Electronics COBHAM RCL-300A Product support manual

TOOLCRAFT 1712612 operating instructions

TOOLCRAFT

TOOLCRAFT 1712612 operating instructions

Elkron IM600 Installation, programming and functions manual

Elkron

Elkron IM600 Installation, programming and functions manual

Bosch WEU PDO 6 Original instructions

Bosch

Bosch WEU PDO 6 Original instructions

THORLABS PDA10JT user guide

THORLABS

THORLABS PDA10JT user guide

Waeco UV-DETECT operating manual

Waeco

Waeco UV-DETECT operating manual

Intermatic IOS-DSIMF manual

Intermatic

Intermatic IOS-DSIMF manual

BTI Profiline Multi Finder operating instructions

BTI

BTI Profiline Multi Finder operating instructions

Challenger SL01 instruction manual

Challenger

Challenger SL01 instruction manual

DMP Electronics 1122INT installation guide

DMP Electronics

DMP Electronics 1122INT installation guide

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

Building Technologies
Fire safety and security products
FDT181 Heat Detector
Product Manual
Overview
The heat detector FDT181 is an intelligent detector. It is used for early fire detection
inside a building.
Characteristics
– With built-in CPU, signals received are processed by intelligent algorithm
– Two operation modes: A2S/A2R
– Automatically address setting without encoder setting or DIP switch
– All-around visible alarm indicator
– Resistant to environment and interference factors such as humidity, corrosive and
vibration, with immunity against electro-magnetic interference.
– Communication via FD18-BUS, polarity free connection
– “Sticker Method” easy for commissioning
Functions
– The detection behavior of the detectors is influenced by the operation mode, so that
it can be specifically adjusted according to the environment to be monitored
– Unique ID of each detector, controller can identify the detector type according to the
ID and assign address
2
Building Technologies
A6V10326261_d_en_--
Fire safety and security products
07.2012
Application
– Suitable for use in places where the ambient temperature can change rapidly or
smoke detector are not suitable
– Dust cap protects the detector from being contaminated by construction work
Indicator
The detector is provided with an internal alarm indicator to show its operating status.
Status
Indicator
Normal
Off
Flashing when connected with FC1840-A3 (for Russian).
Locate/Test
Flashing
Alarm
Steady on
Installation
Easy and time-saving mounting
Install the base and finish the wiring during the construction phase.
1. Point the retaining nest to the positioning pointer and insert it into the base.
2. Turn it clock wisely until it stops.
Uninstallation:
1. Turn it counterclockwisely until it stops.
2. Pull the detector out.
After all the construction is finished, the dust cap must be taken away!
Dimensions
In:mm(with base)
Detector
Retaining nest
Base
Positioning pointer
3
Building Technologies
A6V10326261_d_en_--
Fire safety and security products
07.2012
Connection diagram
51a
6 1b
To next base
Terminal resistor
is not necessary
To controller
FDB181 Base
PP
S
S
Maintenance
Performance test
Recommendation:
– Submit all detectors to an annual visual check. Detectors that are strongly soiled or
mechanically damaged must be replaced.
– Any detectors should be replaced after 7 to 10 years of service, independent from
the environmental conditions.
– Long term auxiliary detectors should be stored with plastic bag.
– Carry out heat test each year.
Technical data
Operating voltage
12 … 32 VDC
Operating current (quiescent)
0.26 mA
Activation current
1.2 mA
Operating temperature
–10 ... +50 °C
Storage temperature
–20 ... +75 °C
Humidity
≤96% (40±2 ℃)
Communication protocol
FD18-BUS
Load factor
1
Color
White, RAL 9010
Protection category EN60529 / IEC529/GB4208-93
IP44
Approval (for Russian) TR RF N123-FZ
Details for ordering
Type
Material No.
Part No.
Designation
Weight
FDT181
S54320-F3-A1
100856212
Heat detector
0.064Kg
FDB181
S54320-F1-A1
100856213
Detector base
0.027Kg
A5Q00022001
100566011
FDT181 dust cap
Beijing Siemens Cerberus Electronics Limited
No.1,Fengzhidonglu, Xibeiwang, HaiDian District,
Beijing, 100094, China
Tel: +10 6476 8806
Fax: +10 6476 8899
© Data and design subject to change without notice.
Doc No.
A6V10326261_d_en_--
Manual FD18
Edition
07.2012
100858265