Optostar OP-8000-EDFA-6U Series User manual

Shenzhen Optostar Optoelectronics Co., Ltd.
A-14,Haide Building, Nanxin Road Nanshan District,Shenzhen,P.R.China
1
OP-8000-6U/2.5U/1U Series DWDM Rack mounted EDFA
Manual
No
t
es
1. Pay attention to the Interface of Fiber Cable, if not, it will affect product performance.
2. When using -48V DC power supply, do not reverse polarity power supply (products supporting the power line: black line 0V / ground, blue line -
48V power supply)。
3. When the device is working, do not stare into the optical ports, to avoid damage to the eyes.
4. Device input optical power level should be within the reception range of the device (see product specific indicators index book or installation
manual).
5. Please keep the optical interface device clean, and Install the protective cover when you don’t use it, in order to avoid falling into the dust.
6. Do not let any object get into the device, and liquid penetrate either, so as to avoid damage to the equipment, and as far as possible to avoid the
use in the following environments:
direct sunlight or high temperature baking where source
drastic changes in temperature environment
dusty or humid place
Strong electric or magnetic fields
corrosive gases, flammable gas or chemical fumes filled the place
7. When the device is working properly, please do not open the case; if faulty, please refer to Chapter 4 :Common Troubles for processing. If still not
resolved, please contact us.
8. If you encounter the following circumstances, please disconnect the device power immediately, and contact us to solve it:
equipment drenched by rain or liquid enters
equipment dropped or the casing is damaged
device emitting a scorched flavor
device is not working
9. When the device is ready to deliver, all parameters have been adjusted, Do not attempt to change the settings or components mobilize board.
EDFA output power is an invisible laser radiation, do not look directly at the amplifier operates its connector end faces, avoiding eye and
skin burns.
1.Equipment Structure and Function Description
1.1 Equipment components
EquipmentOverview
This manual is for a 19-inch rack-type erbium-doped fiber amplifier (EDFA-BA) equipment use. The equipment is mainly used in the case of some
long-distance high speed communications, and improve the line into the fiber optical power.
Equipmentcomponents
Erbium-doped fiber amplifier power equipment front panel as shown:
. Front View
Rack LED
indicator
Management Interface
RJ45,RS232
EDFA Card
indicator
EDFA
input and
output
EDFA
monitoring
PA Front
V
iew
Rack LED
indicator
Management Interface
RJ45,RS232
EDFA Card
indicator
EDFA input
and output
EDFA
monitoring
Red/Blue Input
BA Front View and Output

Shenzhen Optostar Optoelectronics Co., Ltd.
A-14,Haide Building, Nanxin Road Nanshan District,Shenzhen,P.R.China
2
OP-8000-EDFA-6U/2.5U/1U Series DWDM Rack mounted EDFA
Manual
Interface Printing
Name
Function
RJ45
Ethernet Port
Remote Management Interface
Consok
Serial port
Serial Management Interace
In
Inout
EDFA Input Interface
Out
Output
EDFA Output Interface
P_In
PA Input Interface
P_Out
PA Onput Interface
MON
Monitoring Port
1.2 Panel description
1. Device InterfaceDefinition
2. Power Interface Definition
Power Interface illustration Table
Item
Description
-48RTN
Power input positive
-48
Power input negative
3. LED indicator Definition
Panel LED Indicators illustration
Item
Description
PS_A
Powe Supply A normal, green is on.
PS_B
Powe Supply B normal, green is on
FAN
Fan LED, ON is normal
ERR
While error, red is on
RUN
System operating normally, green is on
IN
When the input optical power is below the set threshold input power ,red is on.
OUT
When the output optical power output power lower than the set threshold, red is on
PUMP
Pump laser is abnormal, red is on
mA
Pump current warning LED Indicators , when pump current is abnormal, red is on.
Ptem
Pump temperature warning LED Indicators, when the pump temperature is too high, red is on
Tem
Equipment temperature warning LED Indicators, when the device temperature is too high, red is on

Shenzhen Optostar Optoelectronics Co., Ltd.
A-14,Haide Building, Nanxin Road Nanshan District,Shenzhen,P.R.China
3
OP-8000-EDFA-6U/2.5U/1U Series DWDM Rack mounted EDFA
Manual
4. RS232
Communication
Interface
RS232 interface using RJ45, the pin is defined as follows:
Pin
Description
P
i
n
Description
1
Undefined
6
RS232 Data Input
2
7
Undefined
3
RS232 Data Output
8
Undefined
4
Undefined
9
Undefined
5
Ground
-
-
--
Baud rate 115200 bps, 8 bits transmitted
2.Keyperformance and specifications
Part No.
OP-EDFA-316-12
Parameters
Min
Typ
Max
Units
Remark
Operating
wavelength
1528
1561
nm
Input optical power
range
-15
4
dBm
Gain
12
dB
+/-1 adjustable
Output power
-3
16
dBm
Input optical power
threshold
-20
dBm
adjustable
Gain flatness
1.5
dB
Noise factor
5.5
dB
Operating Voltage
AC220V & DC-48V
V
Dual
Interface
LC/UPC
Size
(W×L×H) 430x320x43.6
mm
Interface
LC/UPC
Size
(W×L×H) 430x320x43.6
mm
2.1 ManagementInterface:
Part No.
OP-EDFA-116-20-NS
Parameters
Min
Typ
Max
Units
Remark
Operating
wavelength
1528
1561
nm
Input optical power
range
-30
-4
dBm
Gain
20
dB
+/-1 adjustable
Output power
-3
16
dBm
Input optical power
threshold
-29
dBm
adjustable
Gain flatness
1.5
dB
Noise factor
5.5
dB
Operating Voltage
AC220V & DC-48V
V
Dual
Interface
LC/UPC
Size
(W×D×H) 430x320x43.6
mm

Shenzhen Optostar Optoelectronics Co., Ltd.
A-14,Haide Building, Nanxin Road Nanshan District,Shenzhen,P.R.China
6
OP-8000-6U/2.5U/1U Series DWDM Rack mounted EDFA
Manual
Rack status page
Business card status informationpage
CONSOLEconnection
Connect PC with the matched RJ45 TO DB9, open the super termial of Windows and set as follows:
Baud Rate 115200 bps
Data Bite 8
Parity None
Stop Bits 1
Flow Control None

Shenzhen Optostar Optoelectronics Co., Ltd.
A-14,Haide Building, Nanxin Road Nanshan District,Shenzhen,P.R.China
7
OP-8000-6U/2.5U/1U Series DWDM Rack mounted EDFA
Manual
User MangementInterface
3.Equipment installation and opening
3.1 Unpacking
Open the received cartons of the MODEL and carefully unpack its
contents. The cartons should Included following items:
Name
Quantity
EDFA
1 Set
Power Supply Cable
2pcs(DC No)
Network Cable
1pc
Serial Cable
1pc
User Manual
1pc
3.2 Installationsteps
3.2.1 After the device removed, placed in a smooth horizontal table or fixed on the frame;
3.2.2 The two sets of screw nut fastening the device to the frameon both sides of the buckle ears, then bolt through the ears and ears
equipment rack, and the final rivet nut tight together;
3.2.3 Respectively the power cord connected to the Blue Line -48V (negative), the black wire to the 0V (positive), the yellow-green cable wire to
protect the ground connection.
3.2.4 The power switch to "ON" state, the indicator on the viewing panel is correct, then the Power (green) and Input Alarm (red) should be
in a light emitting state;
3.2.5 The optical port on the protective cap is removed, the input optical signal, the signal on the line if the connection is correct and, this time,
the panel only the power indicator (green) lights, other are in the off state.
4.Common Problems and Solutions
4.1
1. If no electricity after power on: please check the power supply module type you are using are the same type of power supply, and check the
power of positive and negative polarity. The power supply should comply with the specification 0f the power indicators.
2.Input alarm indicator light: Turn off the power and check the light output optical power is at the entrance of the erbium-doped optical fiber
amplifier input range. If you still can not resolve, make sure the input and output optical port device is reversed. Optical signal wavelength is within
the operating wavelength range of the device.
3.Temperature warning: Make sure that the device ambient temperature is too high。
4.Output alarm, pump alarm: this alarm occurs, turn off the device, and contact us promptly.
4.2 Maintenance
* Do not plug the fiber jumper cables for no reason!
* Do not twist the small curvature of the fiber jumper cables!
* Please regularly maintenance, use alcohol to clean the fiber optic union, attention must first turn off the amplifier power!
* Please regularly check the grounding system is good!

Shenzhen Optostar Optoelectronics Co., Ltd.
A-14,Haide Building, Nanxin Road Nanshan District,Shenzhen,P.R.China
8
OP-8000-6U/2.5U/1U Series DWDM Rack mounted EDFA
Manual
* Please do not open the cabinet!
* Please press the laser safety requires the operator to prevent damage to the laser radiation on the human body!
* Do not frequently turn on or turn off the power, the power to avoid the impact of LD pump source.
Contact OPTOSTAR
Shenzhen Optostar Optoelectronics Co., Ltd
Address:A-14,Haide Building,the Intersection of Nanxin Road and Haide Second Road Nansha n District
Shenzhen,China .
Tel: +86-755-26400198 +86-755-26400288 Fax: +86-755-26411001
Email: [email protected]
Skype:ouyangroya
Web: www.optostar.com.cn
This manual suits for next models
2
Table of contents
Popular Network Hardware manuals by other brands

Belkin
Belkin IEEE 1394 PCMCIA CARDBUS user manual

Somerdata
Somerdata AROW Series Additional Instructions for Installation and Operation

Dragino
Dragino MS14 Development Instruction

Allied Telesis
Allied Telesis iMap 9100 datasheet

ActiveEye
ActiveEye K9504L-W Operation manual

Checkpoint
Checkpoint MHO170 quick start guide