Opvimus DA-4PM/0 User manual

DA-4PM/0 version 1.0.E
1
Mainframe for
4 modular amplifiers
DA-4PM/0
0
9I343 29/05/2020 V1.0.E


DA-4PM/0 version 1.0.E
3
Mainframe for
4 modular amplifiers
DA-4PM/0
Table of contents
1. INTRODUCTION ......................................................................................................................................4
2. FRONT VIEW...........................................................................................................................................4
3. DA-4PM/0 REAR VIEW ............................................................................................................................5
4. CONNECTION .........................................................................................................................................5
4.1. Speakers connection.............................................................................................................................5
4.2. Inputs connection .................................................................................................................................6
4.3. Standby mode control connection ........................................................................................................7
4.4. Main input power supply......................................................................................................................7
5. INSERTING THE POWER AMPLIFIERS MODULES .......................................................................................8
6. AMPLIFIER MODULE FUSE PLACEMENT (ONLY MP-WDC AMPLIFIERS SERIES)..........................................10
7. DA-4PM/0 TECHNICAL CHARACTERISTICS ..............................................................................................11
8. MODULAR AMPLIFIERS MP-WD1 SERIES................................................................................................12
9. MODULAR AMPLIFIERS MP-WDC SERIES................................................................................................13
10. DOCUMENT VERSION TRACKING...........................................................................................................14
11. GUARANTEE .........................................................................................................................................15
WARNING. This is a Class A unit. In a domestic environment this unit may cause radio interferences. In this case the user
must take the necessary precautions.

DA-4PM/0 version 1.0.E
4
Mainframe for
4 modular amplifiers
DA-4PM/0
1. INTRODUCTION
Power amplifier mainframe. It has four slots that allow inserting amplifiers of the MP-WD1 series (models MP-120WD1, MP-
150WD1, MP-250WD1, MP-300WD1 and MP-460WD1), or amplifiers of the MP-WDC series (models MP-120WDC, MP-150WDC,
MP-250WDC, MP-300WDC and MP-460WDC (amplifiers not included).
Main characteristics:
•4 Slots for modular Class D amplifiers. High efficiency (90%).
•100-240 VAC Main input power.
•Secondary 24VDC input power supply independent for each power amplifier module (ONLY MP-WDC modular amplifiers
series).
•DC voltage output for amplifier surveillance.
•Amplifiers standby mode control.
•1u Rack height.
2. FRONT VIEW
1. Slot 1 for amplifier module (amplifier not included).
2. Slot 2 for amplifier module (amplifier not included).
3. Slot 3 for amplifier module (amplifier not included).
4. Slot 4 for amplifier module (amplifier not included).
5. Amplifier module POWER LED indication (see section 8).
6. Amplifier module STANDBY LED indication (see section 8).
7. Amplifier module PROTECT LED indication (see section 8).
8. Amplifier module CLIP LED indication (see section 8).
9. Amplifier module SIGNAL LED indication (see section 8).
Figure 1

DA-4PM/0 version 1.0.E
5
Mainframe for
4 modular amplifiers
DA-4PM/0
3. DA-4PM/0 REAR VIEW
1) DA-4PM/0 Ground terminal.
2) 15A Mains fuse for 220-240 VCA. The device is set
up with a 15A fuse to operate on a main voltage of
220-240 VAC. To work with other main voltages
(100-127 VAC), replace the 15A fuse with the 30A
fuse supplied with the device.
ATTENTION: MAKE SURE TO DISCONNECT THE
POWER CORD FROM THE AC INLET BEFORE
REPLACING A FUSE.
3) 100-240V AC 50/60 Hz AC Inlet connector.
4) Slot 4 / amplifier 4 controls and connections.
5) Slot 3 / amplifier 3 controls and connections.
6) Slot 2 / amplifier 2 controls and connections.
7) Slot 1 / amplifier 1 controls and connections.
8) Amplifier DC Fuse receptacle (see section 6). ONLY for
MP-WDC amplifiers series with secondary 24 VDC power
supply.
9) Amplifier LINE OUTPUT SPEAKERS connection (see
section 4.1).
10) STANDBY Control. Link these two contacts to activate
standby mode (see section 4.3).
11) Amplifier INPUT RJ45 connector (see section 4.2).
12) STANDBY LED indicator. Yellow LED.
The LED lights up when the STANDBY MODE is activated
through the standby control contact of the rear power
strip.
The LED lights blinking when the amplifier hot swapping
screw is not fixed to the mainframe, so the amplifier is in
standby mode.
13) PRIORITY LED indicator. Green LED. Lights when priority
contact (see section 4.2) is activated by an external
device.
14) Amplifier VOLUME adjustment.
15) 24V DC Main connector (see section 4.4). ONLY for MP-
WDC amplifiers series with secondary 24 VDC power
supply.
4. CONNECTION
4.1.Speakers connection
The equipment has four channels (one
per amplifier) for the connection of
100V high impedance speaker lines.
Figure 2
WARNING:
The sum of the power ratings of the loudspeakers
connected to the output of an amplifier must not exceed
the power of the amplifier module.
Figure 3

DA-4PM/0 version 1.0.E
6
Mainframe for
4 modular amplifiers
DA-4PM/0
The connection between the pin 8 and the shielding of the RJ45 connector to the GND
of the DA-4PM/0, and the connection between the GND to the earth of the DA-4PM/0,
is made through the internal jumpers. By default, they are linked. If the installation
requires it, you can isolate by means of these internal jumpers. See figure 5.
4.2.Inputs connection
RJ45 Connectors. Each of the inputs corresponds to an amplifier.
Unbalanced inputs. Sensitivity of 0dB (775 mV rms).
Pin 1: AUDIO INPUT HOT.
Pin 2: GND (or AUDIO INPUT COLD if audio signal input is balanced).
Pin 3: Power supply output. MP-WD1 amplifier series voltage: +15VDC. MP-WDC
amplifier series voltage: +30VDC. Used for amplifier surveillance or to
provide a voltage which can be used to power low consumption devices.
The maximum current supplied is 140 mA.
Pin 4:Not used.
Pin 5: Not used.
Pin 6: PRIORITY INPUT CONTACT. By connecting this contact to ground, the
amplifier is ON even though the STANDBY contact is activated. If the hot
swapping screw is not screwed, the amplifier would remain in standby
mode even if the priority contact is activated.
Pin 7: Not used.
Pin 8:
Metal Shield:
Internal
jumpers x_JP1
GND
Internal
jumpers x_JP2
Figure 4
Figure 5
INPUT 4
INPUT 3
INPUT 2
INPUT 1

DA-4PM/0 version 1.0.E
7
Mainframe for
4 modular amplifiers
DA-4PM/0
4.3.Standby mode control connection
Closed contact: Standby mode ON.
4.4.Main input power supply
The equipment has a 100-240VAC power input which
allows the connection of the equipment to the mains by
means of the supplied cable. Figure 7.
If you are using MP-WDC series amplifiers, the equipment
has 4 secondary 24VDC power inputs independents, one
for each power amplifier module. This allows for these
amplifiers (MP-WDC Series) to be used in safety
installations through their connection to a 24VDC battery
system. Figure 8.
If you use this connection, you must place the
corresponding 24VDC fuse (see section 6. AMPLIFIER
MODULE FUSE PLACEMENT).
STANDBY
CONTROL
Figure 6
Figure 7
Figure 8

DA-4PM/0 version 1.0.E
8
Mainframe for
4 modular amplifiers
DA-4PM/0
5. INSERTING THE POWER AMPLIFIERS MODULES
1. Remove the frontal plate.
2. If you want to use slots 2, 3 or 4, remove
the corresponding slot panel.
Figure 9
Figure 10

DA-4PM/0 version 1.0.E
9
Mainframe for
4 modular amplifiers
DA-4PM/0
3. Insert the amplifier module by fitting it into the slot guides.
4. Fasten the amplifier module by means of the hot-swapping screw.
Figure 12
Figure 11

DA-4PM/0 version 1.0.E
10
Mainframe for
4 modular amplifiers
DA-4PM/0
5. Finally, fix the front plate.
6. AMPLIFIER MODULE FUSE PLACEMENT (ONLY MP-WDC AMPLIFIERS SERIES)
If you use amplifiers MP-WDC Series and the secondary
24VDC power supply connection, you must place the
corresponding 24VDC fuse. Two fuses are delivered with
each amplifier module (1 + 1 spare fuse).
ATTENTION: Each amplifier model
has a different value fuse, depending
of the amplifier power. See Table I.
Figure 13
TABLE I
AMPLIFIER DC FUSE
VALUE
MP-120WDC 7.5A
MP-150WDC 10A
MP-250WDC 15A
MP-300WDC 20A
MP-460WDC 25A
Figure 14

DA-4PM/0 version 1.0.E
11
Mainframe for
4 modular amplifiers
DA-4PM/0
7. DA-4PM/0 TECHNICAL CHARACTERISTICS
Input contacts Standby activation contact (independent for each amplifier).
Audio inputs 4 inputs, 0dB (775 mV rms).
Audio outputs 4 Independent audio outputs for speakers lines (100V).
Max. Output level 100V
Frequency response (-3dB) 20 Hz - 20 kHz
Signal/noise ratio Better than 75 dB
Power supply 100-240 VAC.
24VDC secondary (only for MP-WDC Series).
Indicators
Frontal: POWER, STANDBY, PROTECT, CLIP and SIGNAL LED indicators, for each
amplifier.
Rear: STANDBY and PRIORITY LED indicators, for each amplifier.
Weight 4 kg (amplifier modules not included).
Finishes RAL9005 Iron painted black.
Measurements (mm) 482.6 (width) x 44.4 (height) x 430 (depth).
19” Rack units 1

DA-4PM/0 version 1.0.E
12
Mainframe for
4 modular amplifiers
DA-4PM/0
8. MODULAR AMPLIFIERS MP-WD1 SERIES
Class D amplifiers. High efficiency (90%). Hot swap. Several power available (120, 150, 250, 300 & 460 Watts).
MP-120WD1 MP-150WD1 MP-250WD1 MP-300WD1 MP-460WD1
Output Power
120W 150W 250W 300W 460W
Leds POWER, STANDBY, PROTECT, CLIP and SIGNAL
Fan
No No No Yes Yes
THD+N (@1kHz)
<0.6% <0.6% <0.6% <0.6% <0.6%
Consumption Standby
Idle
Max
3.5W
6.5W
134W
4W
7.2W
165W
4W
7W
276W
4W
7.2W
339W
4W
7.2W
520W
AC Fuse
NOT USED IN MP-WD1 SERIES WITH DA-4PM/0 MAINFRAME
Power supply (Mainframe)
100-240 VAC
MP-120WD1
MP-150WD1
MP-250WD1
MP-300WD1
MP-460WD1
POWER LED. Power supply indicator of the amplifier
module.
STANDBY LED.
PROTECT LED. It lights when the amplifier protection acts,
due to an overload or a short circuit in the loudspeaker
line, or to excessive heating of the power stage
CLIP LED. It lights that the power stage reaches the
maximum output voltage (100V).
SIGNAL LED. Indicates reception of audio signal at the
input of the power stage.
Hot-swapping screw. If the screw is not fixed to the
mainframe the amplifier is on standby mode.

DA-4PM/0 version 1.0.E
13
Mainframe for
4 modular amplifiers
DA-4PM/0
9. MODULAR AMPLIFIERS MP-WDC SERIES
Class D amplifiers. High efficiency (90%). Hot swap. Several power available (120, 150, 250, 300 & 460 Watts).
MP-120WDC MP-150WDC MP-250WDC MP-300WDC MP-460WDC
Output Power
120W 150W 250W 300W 460W
Leds POWER, STANDBY, PROTECT, CLIP and SIGNAL
Fan
No No No Yes Yes
THD+N (@1kHz)
<0.6% <0.6% <0.6% <0.6% <0.6%
Consumption Standby
Idle
Max
3.5W
6.5W
134W
4W
7.2W
165W
4W
7W
276W
4W
7.2W
339W
4W
7.2W
520W
DC Fuse
7.5A
10A
15A
20A
25A
Power supply (Mainframe)
100-240 VAC
Secondary power supply 24 VDC
MP-120WDC
MP-150WDC
MP-250WDC
MP-300WDC
MP-460WDC
POWER LED. Power supply indicator of the amplifier
module.
STANDBY LED.
PROTECT LED. It lights when the amplifier protection acts,
due to an overload or a short circuit in the loudspeaker
line, or to excessive heating of the power stage
CLIP LED. It lights that the power stage reaches the
maximum output voltage (100V).
SIGNAL LED. Indicates reception of audio signal at the
input of the power stage.
Hot-swapping screw. If the screw is not fixed to the
mainframe the amplifier is on standby mode.

DA-4PM/0 version 1.0.E
14
Mainframe for
4 modular amplifiers
DA-4PM/0
10. DOCUMENT VERSION TRACKING
Reference system Type of Document Confidentiality N/A
DA-4PM/0 Installation and operation guide
Rev Date Modifications Content Written by:
1.0.E May 2020 1st Version R+D Department
Approved By Function Date
Ferran Gironès i Puig R+D Director 05/2020

DA-4PM/0 version 1.0.E
15
Mainframe for
4 modular amplifiers
DA-4PM/0
11. GUARANTEE
1. GUARANTEE CERTIFICATE
1. OPTIMUS S.A. guarantees that its products are free from material and
manufacturing defects when they are first delivered to the purchaser.
2. In accordance with the conditions outlined here, OPTIMUS S.A. guarantees
its products for two (2) years from the date on which the purchaser acquires the
product. If, within this guarantee period, defects appear which are not due to
factors outlined in section 2, OPTIMUS S.A. shall replace or repair the unit using
equivalent, new or reconstructed replacement parts, as it deems fit. If
replacement parts are applied which improve the unit, OPTIMUS S.A. reserves
the right to charge the client for the additional cost of these components.
3. No guarantee benefits shall be provided other than those cited here.
4. In order to claim the guarantee rights, it shall be an essential requirement
to present the original purchase invoice or the guarantee certificate.
2. GUARANTEE PROVISIONS
1. In the event that the product had to be modified or adapted to comply with
local requirements concerning technical specifications or safety, and if the
country in question is not the country for which the product was originally
designed and manufactured, defects are not considered to be material or
manufacturing defects. Furthermore, the guarantee does not cover the
execution of these modifications or adaptations, regardless of whether or not
they have been carried out correctly.
Nor shall OPTIMUS S.A. be responsible for any costs under this guarantee for
these types of modifications.
2. The guarantee shall not entitle the purchaser to inspection or free
maintenance or repair of the unit, particularly if the defects are due to
inappropriate use. Nor do the guarantee rights cover defects in wearing parts
that become worn as a result of normal wear and tear. Wearing parts are, in
particular, potentiometers, switches/knapper, and similar parts.
3. The guarantee does not cover defects in the equipment unit caused by:
•Abuse or incorrect use of the unit for purposes other than those for which it
is intended, in non-compliance with the service and maintenance
instructions specified in the Manual and/or Technical Instructions for the
unit.
•Stik/konnektor or use of the product in a manner that does not correspond
to the technical or safety requirements of the country in which the unit is
used.
•Installation in conditions other than those indicated in the Manual and/or
Technical Instructions.
•Deficiency or interruptions in the electricity supply or installation defects
which imply use in abnormal conditions.
•Damage caused by other equipment units that are connected to the
product.
•The use or installation of Software (programmes), interfaces, parts or
supplies not provided and/or not authorised by OPTIMUS S.A.
•Fejlure to use the original packaging for transportation.
•Damage caused by force majeure or other causes not attributable to
OPTIMUS S.A.
4. The following elements are not covered by this guarantee:
•All plastic surfaces and all parts exposed to outdoor conditions which have
been scratched or damaged as a result of normal or abnormal use.
•Breakages, knocks, damage due to a fall or scratches caused by moving the
unit in any way.
•Damage caused by tests, use, maintenance, installation or inappropriate
adjustments, or as a result of any alteration or modification of any kind not
carried out by a Service Authorised by OPTIMUS S.A. in compliance with this
guarantee.
•Damage to persons or property that might be caused by the improper use
of the equipment, including lack of maintenance.
5. The guarantee shall not be valid whenever the following is observed:
•Amendments or corrections made to the details of the guarantee certificate
or purchase invoice.
•Fejlure to produce the original invoice or the absence of a date on this.
•Absence of the serial or batch number on the equipment.
6. In the case of personal computers, the guarantee will not cover the
elimination of computer viruses, the restoration of programmes damaged by
these or the reinstallation of the disk following its deletion.
7. The rights of this guarantee are invalidated if the product has been repaired
or opened by staff unauthorised by OPTIMUS S.A. or by the client himself.
8. If OPTIMUS S.A. were to establish before the client that the damage
affecting the unit does not entitle a claim to be made under the guarantee, the
costs of checking the equipment incurred by OPTIMUS S.A. shall be borne by the
client.
9. Products not covered by the guarantee shall only be repaired once payment
has been effected by the client. In the event that the guarantee rights do not
apply, OPTIMUS S.A. shall duly inform the client. If, within a period of 6 weeks
from this communication, no written repair order is received from the client
confirming acceptance of the costs, OPTIMUS S.A. shall return the unit in
question to the client. In this case, the transport and packaging costs shall be
invoiced separately and payment shall be made on delivery. In the event that a
repair order is sent by the client, confirming that he assumes the costs of repair,
the transport and packaging costs shall be invoiced additionally, and also
separately.
10. If the equipment needs to be transferred to the Authorised Service Centre,
transportation shall be effected by the responsible party according to the
guarantee, who will also bear the freight and insurance costs.
11. In the event of a defect, OPTIMUS S.A. guarantees that the repair and/or
replacement of parts so that the unit operates correctly will be made within a
period of no more than 30 days. Nevertheless, OPTIMUS S.A. would like to clarify
that the normal period does not exceed 30 days.
12. All parts or products replaced as part of the guarantee services shall
become the property of OPTIMUS S.A.
3. TRANSFER OF GUARANTEE
The guarantee is solely awarded to the original purchaser (principal client) and is
not transferable. With the exception of OPTIMUS S.A., no third party (dealers,
etc.) is authorised to award additional guarantees on behalf of OPTIMUS S.A.
4. CLAIMS FOR DAMAGE
In the event that OPTIMUS S.A. cannot provide a suitable guarantee service, the
purchaser shall not be entitled to claim any indemnity for damages arising. The
responsibility held by OPTIMUS S.A. is limited in all cases to the invoicing price of
the product.
5. RELATION WITH OTHER GUARANTEE RIGHTS AND NATIONAL LAW
1. This guarantee does not affect the rights of the purchaser with respect to the
vendor arising from the contract of sale accomplished.
2. These conditions of the guarantee provided by OPTIMUS S.A. are valid as long
as they do not contradict the corresponding national law on guarantee
provisions.
3. OPTIMUS S.A. guarantees that this product complies with the safety
regulations in force in the country.
THIS LIMITED GUARANTEE DECLARATION IS THE EXCLUSIVE GUARANTEE
OFFERED BY OPTIMUS S.A. ALL OTHER EXPLICIT OR IMPLICIT GUARANTEES ARE
EXCLUDED, AND THIS ALSO APPLIES TO GUARANTEES OF MARKETABILITY AND
SUITABILITY FOR A PARTICULAR PURPOSE. (EXCEPT WHEN THESE GUARANTEES
ARE REQUIRED BY AN APPLICABLE LAW). NO GUARANTEE, EITHER EXPLICIT OR
IMPLICIT, SHALL BE APPLIED ONCE THE GUARANTEE PERIOD HAS EXPIRED
OPTIMUS S.A.
After Sales Service
C/ Barcelona 101
17003 - GIRONA
Tel. 902 151 96 / 972 203 300
Fax. 972 21 84 13
e-mail:girona@optimus.es 1999/44/CE

9I343 29/05/2020 V1.0.E
Table of contents
Other Opvimus Amplifier manuals