1.6. Directive and Standard Compliance
To use the 1397E & 1398E in a hazardous environment the following directives are applicable.
and only when Energizer 522 PP3 battery is used.
Directive Compliance:
ATEX : II 2 G Ex ia IIB T4
The 1397E & 1398E are designed according to the following standards.
Use of Standards:
EN 60079-0 Electrical apparatus for explosive gas atmospheres – Part 0: General requirements
EN 60079-11 Electrical apparatus for explosive gas atmospheres Intrinsic safety ‘I’
EN 60529 Degrees of protection provided by enclosures (IP Code)
EN 13922 Tanks for transport of dangerous goods- Service equipment for tanks- Overfill prevention
systems for liquid fuels
2 Initial installation
No special measures have to be taken to install the tester. This Product is ready for use when taken from the
box.
3 Maintenance
Do not store the tester for a long period with a battery attached. Leakage of the battery and corroding of the
clips may occur
Contact pins are spring loaded and should be clean for proper operation. Replace battery when red light is
flashing rapidly.
4 Operational Use
Place the plug, blue on a 3J-slot socket or black on a 4J-slot socket. One of the spring loaded pins will
energize the circuit. A short green flash on the rear of the plug will indicate that power is applied. A test
sequence is started to analyze the sensors and verifies the ground connection. A bicolor led pattern will
indicate the status of the sensors (see figure 1). A second circuit is designed to verify the connection
between pin 9 and 10. If the impedance is within the specifications of the EN-NEN13922 6.1.2 Bonding. a
white Led is flashing on the rear of the plug. After 10 minutes the tester will be switched to hibernate and the
power to the sensors will be switched off to preserve power. To re-start the tester the plug has to be removed
from its socket and replaced.
5 Key features
•No operating action required
•Bi-color Led indicator for amount of compartments
•Separate White Led indicator for ground verification
•Test ground loop and ground bolt
•Fitted with an approved Energizer 522 PP3 battery
•Available for 3-J and 4-J slots
•Extra diagnostic information available
•Robust and small housing, can be stored in truck cabin
•Auto switch off when removed from socket
•Auto switch to hibernate after 10 min. to preserve battery life
For additional features please contact OPW Fluid Transfer Group Europe bv.