Oracle Audio PARIS PH100 User manual

The Fine Art of Playing Music
Oracle Audio Technologies
Paris PH100 Phono Preamplifier
Owner’s Manual

Oracle Audio Technologies
Paris PH100 phono preamplifier
2
FOREWORD
We would first like to thank you, and this from the whole team at Oracle Audio,
for purchasing our Paris PH100 phono preamplifier !
This is your Paris PH100 Owner’s Manual. The following pages will describe the
key features, connectivity and safe operation of your new phono preamplifier. Although
some operations are self explanatory, we strongly suggest you read this booklet to
better understand the importance of the different key adjustments.
FOR YOUR RECORDS
Paris PH100 Serial Number:
Dealer’s Name:
Dealer’s Address:
Dealer’s Phone:
Purchase Date:
We suggest you keep your sales slip together with this owner’s guide as it stands as
your proof of purchase which is essential for the validation of your warranty.

Oracle Audio Technologies
Paris PH100 phono preamplifier
3
TABLE OF CONTENTS
Foreword / For your Records ...........................................................................................2
Table of contents .............................................................................................................3
Features ………………………………...............................................................................4
Gain and Impedance settings ..........................................................................................5
Connection procedure .....................................................................................................6
Operating instruction and specifications .........................................................................7
Waranty ...........................................................................................................................8
Waranty Registration Card...............................................................................................9
.

Oracle Audio Technologies
Paris PH100 phono preamplifier
4
Features
Input / Output
There is one input ( R & L ) and one output ( R & L ) using RCA connectors.
RIAA Equalization
The RIAA circuit is designed by following the true RIAA standard.
The accuracy of RIAA standard curve is +/- 1dB.
Jumper-selectable gain setting
The Oracle Paris PH100 phono preamplifier has 3 gain settings. The gain must be
adapted to match your cartridge’s output with the input of your PH100 to provide an
optimal volume level and to prevent any overloading which would cause distortion.
Those settings are done by changing the position of a specific jumper as indicated in
the diagram on page 5 of this user manual.
The different gain levels are 41.5dB, 52dB or 62dB.
Jumper-selectable load impedance setting
The Oracle Paris PH100 phono preamplifier allows 5 different impedance settings. The
impedance is modified by changing the position of specific jumpers on each stereo
channel as indicated on the diagram on page 5.
-For MM phono cartridges (moving magnet) use the 47k Ohms load impedance
(standard).
-For MC phono cartidges (moving coil) you can choose an impedance of 100, 200, 511,
1k and 1.5K ohms.
Fixed value capacitance
-The 47k Ohms setting is coupled with a fixed capacitive charge of 150pF.
-There is no capacitive charge for the moving coil resistive load settings.
-The default factory gain setting is set at 41.5k with a resistive load of 1k Ohms.

Oracle Audio Technologies
Paris PH100 phono preamplifier
5
Gain and Impedance setting
Moving Magnet (MM) cartridge gain & load setting:
Use the standard 47k Ohms impedance jumper setting on both channels
as shown in the diagram below with a gain of 41.5dB.
Moving coil (MC) cartridge gain & load setting:
Always follow the recommendations from your cartridge’s manufacturer to
determine whether to use the 100, 200, 511, 1K or 1.5K Ohm load
impedance setting. As a guideline, the phono cartridge output of 1,5mv to
2,5mv should use the 52dB. Phono cartridges with an output under 1,5mv
should use the 62dB gain setting.
IMPORTANT NOTE ABOUT JUMPER POSITIONING
1 ) ONE JUMPER MUST ALWAYS BE INSTALLED ON
ONE OF THE 3 "GAIN" JUMPER POSTS
2 )
THE SECOND JUMPER MUST BE INSTALLED ON
EITHER ONE OF THE 5M/C LOAD POSTS
OR ON THE M/M 47K ohms POSTS
3 )
FOR M/M 47K ohms SETTING ALWAYS
USE THE 41,5 db GAIN SHORTING POSTS
Gain 62 db
Gain 52 db
Gain 41.5 db
No Connection
M/M 47K ohms
M/C 100 ohms
M/C 200 ohms
M/C 511 ohms
M/C 1k ohms
M/C 1,5k ohms
ORACLE PARIS PH-100 CARTRIDGE LOADING

Oracle Audio Technologies
Paris PH100 phono preamplifier
6
CONNECTION PROCEDURE
Ground connection
The knurled nut connection post between the INPUT and the OUTPUT is to be linked
with your tonearm / turntable’s ground lead.
Input RCA connectors
Connect the leads coming from your tonearm to the R & L “INPUT”of the PH100.
Note : The audio interconnect cables required for this connection are not included.
Output RCA connectors
Connect the RCA interconnect leads from the R & L “OUTPUT”of the PH100 to an
auxiliary INPUT of prepreamplifier or integrated preamplifier. Do not connect to a
turntable INPUT because this could be linked to an internal phono preamplifier section
of your integrated preamplifier.
Important note : The PH100 always has to be connected to an auxiliary input. Never
hook up the PH100 into a phono input on your amplifier or preamplifier.
AC Power
Connect of the supplied power cord to an AC wall outlet.

Oracle Audio Technologies
Paris PH100 phono preamplifier
7
OPERATING INSTRUCTIONS
Operating your audio system should always be done by following an orderly ritual both
when powering it up or powering it down. We suggest you always begin by powering up
the phono preamplifier first followed by the pre-preamplifier then the preamplifier section
after a moment. Following this procedure will prevent hearing a loud thumping sound
generated by source components as they charge up their electronics. Powering down
your sound system should always be done by beginning with preamplifier, pre-
preamplifier to then finish with the phono preamplifier.
Always operate your Oracle PH100 phono preamplifier in a well ventilated area to avoid
overheating. Phono preamplifiers are very sensitive to their electromagnetic
environment and it is recommended to position your Paris PH100 as far as possible
from your preamplifier and other high voltage equipment or wires. Proximity to such
devices can create “HUM” noise. Such noise could definitely pollute the audio signal
noise and lessen the sonic performance of the Paris PH100 thus adversely impact your
musical experience.
SPECIFICATIONS
Frequency Response : 20Hz - 20KHz @ +/- 1dB
Total Harmonic Distortion : < 0,05% @ 20Hz –20kHz
Moving Coil impedance settings : 100, 200, 511, 1k, 1.5K and 47K Ohms
Moving Magnet impedance setting : 47k Ohms
Input Capacitance MM : 150pF
Input sensitivity : 0,3mV and up
Gain MC : 41.5db, 52db, 62db
Gain MM : Must be set at 41.5 dB & 47k Omh
Signal to noise ratio : > -80dB

Oracle Audio Technologies
Paris PH100 phono preamplifier
8
WARRANTY
Your new Oracle Paris PH100 carries a transferable, 2 year parts and labor limited
warranty against operation defects under “normal use” or manufacturing defects.
Oracle Audio Technologies will repair the defective item within this warranty period. The
original bill of sale from an authorized dealer or distributor is required for any warranty
repair. If the original bill of sales cannot be shown as a legitimate proof of purchase date
then the serial number will be used to determine the ship date from the factory and the
warranty coverage will be 2 years and 6 months from the shipping date from the factory.
Explanation of the term “normal use”:
- Using the PH100 for the application it was designed which is as a phono
amplifier.
- The unit has been connected rigorously according the information supplied in the
owner’s manual.
Maintenance and service :
Any repair and/or modification done to the PH100 must be carried by an Oracle Audio
authorized service center or directly at the Oracle Audio factory. For more information
please contact your dealer, distributor or contact us directly at Oracle Audio.
Any repair and / or modification done to your PH100 without prior authorisation from
Oracle Audio will void the warranty.

Oracle Audio Technologies
Paris PH100 phono preamplifier
9
We are confident your new Oracle Audio product will give you
many years of enjoyment and satisfaction
You are now ready for the real and only purpose of all this...
to sit down, relax, and enjoy the Fine Art of Playing Music
Oracle Audio Technologies Inc
6136 Boulevard Bertrand Fabi, Suite 101
Sherbrooke, Quebec, Canada
J1N 2P3
Phone: 1-819-864-0480 Fax: 1-819-864-9641
e-mail: info@oracle-audio.com
www.oracle-audio.com
WARANTY REGISTRATION CARD
Oracle Paris PH100 ; serial number : ____
Dealer’s name: _____
Dealer’s address :
Dealer’s phone number:
Your name: _____
Your address: _____
Telephone : E-mail : _____
Date of purchase: _____
Table of contents
Other Oracle Audio Amplifier manuals
Popular Amplifier manuals by other brands

SOLIS
SOLIS BSS-006 user manual

Linear Power
Linear Power 452i Owner's manual and installation guide

Altec Lansing
Altec Lansing Anniversary Series Operating and service instructions

FMR Audio
FMR Audio R-390B quick start guide

Marshall Amplification
Marshall Amplification VDA-104-3GS-2 user manual

Laney
Laney Nexus NX410 operating instructions