Orbis CODITEL User manual

User manual
GSM COMMUNICATION INTERFACE
Read all instructions carefully
CODITELisacommunicationinterfaceinacontainerof4DINmodules,whichusesGSM
technologytoenabletheremotecontrolofelectricservicesinthehome.Theoutputrelay
canbecontrolledbysendingatextmessagefromyourmobilephoneorbyringinganenabled
telephoneservice,thussavingthecostofthetextmessage.Theinstrumentalsooffersthe
optionofreceivingatextmessageconfirmingactivation.
SAFETY WARNINGS
During the installation and operation of the device observe the following instructions:
1) The device must be installed by a qualifi ed person
2) The device is aimed to be used in household premises and similar environments
3) Do not use the device for purposes other than indicated
4) A two-pole disconnect device shall be provided as part of the building installation
5) A protection device against over-currents should be installed in the electrical system,
upstream of the device
6) When installing the device, carefully respect the wiring diagrams
7) Disconnect the device from the power supply before accessing to the terminals
8) Do not power or connect the instrument if any part of it is damaged
9) The use of a GSM device can cause interference with the functioning of electronic
devices non-screened from radiofrequency signals (electromedical devices, pacemakers,
hearing aids etc.)
10) In case of fault, do not service the device yourself but contact the after-sales service.
11) The device is aimed for use in place with over-voltage category III and pollution
degree 2, as per standards EN 61010-1.
TECHNICAL CHARACTERISTICS
• Powersupply:230V~(-10%÷+10%)50Hz
• Consumption:4VA
• Connection:
−cableswithmax6mm2section
• Output
− abistablerelaywithexchangecontact
− breakingcapacity:8(5)A/250V~
• GSMDualBandmodule(900-1800MHz)
• SMA-Fconnectorforexternalaerial(includedinthebox)
• Youcanstoreupto100numbers
• SignalLEDs:
− Red LED for signalling the output relay status
− Red/greentwotoneLEDforsignallingthedevicestatus
• Multipurposebuttonforinstrumentprogramming
• Operatingtemperature:0÷50°C
• Operatinghumidity:10÷90%noncondensing
• Storagetemperature:-10÷+65°C
• Protection:IP40
• Container:4DINmodules
INSTALLATION
• Inorderfortheinstrumenttooperate,asimcardenabledfortelephonetrafficneedstobe
inserted in the relative slot.
Note. Ensure that the power cables are disconnected before inserting the sim
card.
Remove the cover and use a sharp object to press the slot release mechanism, as illustrated
intheboxalongside:
Attention. The SIM should have the PIN code request and the answerphone
deactivated.
• OncetheSIMhasbeeninserted,powertheinstrumentbyconnectingthewiresasillustrated
inthe“connectiondiagrams”box.
Thestatusofthedeviceissegnalatedbythebicolorled :
OFF: system not fed
BLINKINGRED:sim not inserted or pin code in activity
FIXEDRED:GSM field insufficient
FIXEDGREEN:startingsystem/networkresearch
BLINKINGGREEN:connectedtoGSMnetwork
QUICKLYBLINKINGGREEN:arrivingincommand(ringorsms)
QUICKLYBLINKINGRED:programming mode active
• Onceithasbeenconnected,theinstrumentwillbecomefullyoperativewithinaround30
seconds,duringwhichtheinstrumentstatusLEDwillbeafixedgreencolour(thetime
neededtosearchforthenetworkandinitialisetheinstrumentmayvaryonthebasisofthe
GSMfieldinwhichtheinstrumentisinstalledandtheproviderused).
Oncetheinitialisationphaseiscompleted,thegreenLEDwillstarttoflashwithafrequency
of1Hzandtheinstrumentwillbereadytoreceivecommandsviatextmessageoraringon
the telephone.
Note. If the device will be installed into a screened panel, it is possible to replace
the antenna included in the kit with an another one with 3 meters cable.
The longer antenna is available as optional. Ensure that the power cables are
disconnected before replace the antenna.
OPERATION
Reset the device
• Whenitisswitchedonforthefirsttimeandwheneveritisreset,theinstrumentwillbeset
withthedefaultparameters.Todoareset,switchonthedeviceandpressthekeyshortlyin
threeseconds.Theledrelativetotheoutputwillblinkforfewseconds.
Set the certified numbers
In order to use the instrument, it is necessary to begin by setting the number of admins and
theusernumbersenabled(ifany).Pressingthekeyforalongtime(atleast5seconds)allows
youtoentertheprogrammingmode,whereyoucanenable/disablethevarioustelephone
services.
• Setting the admin number
Afterswitchingtheinstrumentonandaftereschreset,forthefirsttimeandhavingentered
programmingmode,thefirsttelephonenumberthatmakesacallwillautomaticallybe
configuredastheadminnumber.Theadminnumbercanbechangedlateronbysendinga
textmessagefromthecurrentadminnumberwiththecommand:
ADMIN [newadminnumber](thenewadminnumbermustbeininternationalformat
+39…)
If you lose the admin number, it can only be changed by forcing an instrument reset.
Toretrieveautomaticallyalltheusernumbers,seethesection“Simmanagment”.
• Setting the user number
Theusernumberscanbeentered/removedsimplyviaatelephonecallwhentheinstrument
isinprogrammingmode.Thecaller’snumberwillbeentered/removedonthebasisof
whetheritisrespectivelynotpresent/presentinthephonebook.Aconfirmationtext
messagewillbesenttothecaller,indicatingthenumberoflocationsoccupiedoutofthe
totalnumberavailable.Alternatively,theusernumberscanbeaddedorremovedbysending
atextmessagefromtheadminnumberwiththecommands:
USERADD [list of numbers to be added]
USERDEL [list of numbers to be removed]
Thenumberstobeaddedmustbeininternationalformat+39…andseparatedbyanempty
spacebetweeneachnumber.
Commands
CODITELhasarelayoutputwhosestatusissignalledbyaredLED(onoutputON).
Itispossibletoworkontheoutputasfollows:
− withthekeyonthefrontpanel,whichcanbeusedtoforcetheoutputswitch.Theadmin
numbercansettheoutputactionafterpressingthekeywiththecommand:
OUTKEY [functionality]
withfunctionalitythatcanassumethevalues:
RING itreactsasitdoestoacallwhenthekeyispressed
TOGGLEthekeyswitchestheoutputON/OFFinbistablemode
BLOCKdisablesthekeyfunctionality(itisnotpossibletoaccessprogramming
modewheninthismode)
Ifthevalueisomitted,thecurrentinstrumentstatuswillbetheresponse.
− withtelephonecallfromanenablednumber.
Theadminnumbercandefinetheactionoftheinstrumentwhenitreceivesacallby
sendingatextmessage.Thepossiblecommandsare:
RINGRISP [status]
withstatusthatcanassumethevalues:
ONsendsatextmessageconfirmingactivationtothecaller
OFFnoconfirmationtextmessagetothecaller
Ifthevalueisomitted,thecurrentinstrumentstatuswillbetheresponse.
RINGCONTROL [status]
withstatusthatcanassumethevalues:
ONcontrolsthecallernumbertocheckwhetheritisenabled
OFFdoesnotcheckthecallernumber(functionusedwhenyouwishto
temporarilyallowanynumbertocontroltheinstrument)
Ifthevalueisomitted,thecurrentinstrumentstatuswillbetheresponse.
OUTRING [output status] [status permanence time] [time unit of measurement]
inwhichtheparameterscanassumethefollowingvalues:
output status ON,OFF,TOGGLE,DISABLE
status permanence time maximum(232-1)seconds(optionalparameter)
time unit of measurement sseconds,mminutes,hhours(optionalparameter)
Examples:
OUTRINGOFF10StherelayisturnedOFFfor10secondswhenthecallisreceived
OUTRINGDISABLEtherelaydoesnotdoanythingwhenthecallisreceived
OUTRINGTOGGLEtherelaychangesstatuswhenthecallisreceived
− withtextmessagefromtheadminnumberoranothernumber(viapassword).
Thestructureforallthecommandsisasfollows:
[password][separator][command][separator][parameter1][separator]..[parameterN]
where:
[password]numericalfieldofamaximumof8figures
[separator] comprised of one or more space characters
[command] command recognised by the device
[parameter..] series of parameters relative to the command
The password field may be omitted if the command is given by the admin
number. Several commands may be included in one text message. In this case,
the commands executed will only be those whose response is contained in a
standard text message (160 characters). To enter numbers with the decimal
separator, you need to use a full stop.
Thestructureofaresponsetoacommandissimilartothecommanditself,withtheaddition
ofthe“=”symboltoindicatethecurrentstatus.Forexample:
OUTKEYBLOCKOUTKEY=BLOCK
Inadditiontothoselistedabove,thecommandswhichcanbemadeviatextmessageare:
•Setting the output status
OUT [output status] [status permanence time] [time unit of measurement]
where:
output status ONorOFF
status permanence time (232-1)seconds(optionalparameter)
time unit of measurement sseconds,mminutes,hhours(optionalparameter)
Iftheoutputstatusisomitted,theresponsewillbethecurrentinstrumentstatus.
Example:
OUT ON 10 M outputONfor10minutes
•Setting the sending of a caller response message
OUTRISP [status]
withstatusthatcanassumethevalues:
ONenablesthesendingofatextmessageinresponsetothecaller
OFFdisablesthesendingofatextmessageinresponsetothecaller
Ifthestatusisomitted,theresponsewillbethecurrentinstrumentstatus.
Example:
OUTRISP ON
•Displaying the output status and the settings
OUTINFO
Apossibleanswearcouldbethefollowing:
OUT=ON OUTRING=ON 5s OUTRISP=ON RINGRISP=OFF OUTKEY=TOGGLE
Itmeans:
outputON,ONfor5secondswhenthecallisreceived,confirmationtothesmsabled,
confirmationtotheringdisabled,thekeyswitchestheoutputon/offinbistablemode.
•Changing the output name
OUTTXT [output label]
Example:
OUTTXT valvola assigns to the output the name valvola
A string of a maximum of 10 characters with no spaces can be assigned as a
name. To restore the original name, just write OUTTXT NO. If an alternative
name is defined for the output, this name can be used instead of OUT1.
For example:
valvola ON 10 M activeoutput(valvola)for10minutes
•Enabling the forwarding function(foradminsonly)
FORWARD [number]
It’spossiblesetanynumber.Inthiscase,thesmsthatnocontaincommandforthedevice
areforwardtothenumberspecified.Ifnotmodified,thenumberthatreceivedtheunknown
sms is the admin.
FORWARD OFF disabled this function.
Example:
FORWARD +391111234567 forwardtothe11111234567numberthesms
that no contain commands
•Password management(foradminsonly)
PASS[newpassword]withnewpasswordwithamaximumof8figures
Example:
PASS 12345678
• Simcardmanagment(foradminonly)
STORE copy in sim card all the number saved in the device
RESTORErestoreonlythenumberssavedwiththecommandSTORE
Thesecommandsareparticularyusefulinthecaseofreset,withconseguentlossoftheuser
numbers saved in the device.
Forthis,werecomandyoutodoaSTOREwhenallthenumbersareabilitated.
REFERENCE STANDARDS
ConformitytotheEUdirective:
1999/5/CER&TTE
declaredinreferencetotheHarmonisedStandards:
Safety:EN60950-1
Electromagnetic compatibility:EN301489-1andEN301489-7
DIMENSIONS
CONNECTION DIAGRAMS
DEFAULT SETTING
GATE-OPENER FUNCTION
OUT 1
8 A / 250 V ~
127 8 9
Password 12345678
Relay output status OFF
ADMINnumber Undened
USERnumbers Not defined
Callercontrol Active
Automaticcallanswer Disabled
Response to sms commands Active
Forwardunknownsms Active
• TouseCODITELasgate-openerisenoughinsertasimcard,feedsupplypowerthe
instrumentandwaitforthegreenledtoflash.Pressthebuttonforatleast5secondsto
enter in the programming mode.
Makearingfromatelephonenumberwhichwillbeconfiguratedasadminnumber.
Fromthisnumber,sendamessagecontainingthelistofnumbersthattobeabilitated
asgate-openermode,bythecommand:
USERADD [list of numbers to be added]
Thenumberstobeaddedmustbeininternationalformat+39…andseparatedbyan
emptyspacebetweeneachnumber.Ifthemessageislongerthan160characters,divide
it in more sms.
Numbersarenowabilitatedtoopenthegate.
Note. CODITEL sends an impulse of 2 seconds to the unit gate-opener.
To modify the duration of the impulse, see the OUTRING command.
72 6
45
87
0
Out
ON
SET
CODITEL
499-010
Other Orbis Recording Equipment manuals