Orphee MYTHIC 18 Quick start guide

01/09/2009 - 1 - Orphée S.A/M18/SEW/003
Mythic™18
Service Engineer Training
Workbook

01/09/2009 - 2 - Orphée S.A/M18/SEW/003
Proprietary Statement
Copyright 2006, Orphée S.A. All rights reserved. No part of this document
may be reproduced, stored in a retrieval system or transmitted in any
form or by any means, electronic, mechanical, photocopied, recorded, or
otherwise, without the prior written permission of Orphée S.A.
Service engineer training workbook usage disclaimer
Information contained in this document was developed for use by trained
Orphée S.A. service engineers personnel, or by other persons
knowledgeable or experienced with operation and service of the Mythic
system.
Trademark statements
Mythic is a trademark of Orphée S.A.

01/09/2009 - 3 - Orphée S.A/M18/SEW/003
Revision history Pages revised and added
SEW/001 12/2006 First release
SEW/002 12/2007 Second release
Add version 2.0.0 specifications
New electronic gain adjustment
procedure
SEW/003 09/2009 Third release
Add Electronic troubleshooting

01/09/2009 - 4 - Orphée S.A/M18/SEW/003
Mythic™18 Service Engineer Training Workbook
Index
Section 1……………………………Overview
Section 2…………………………..User Interface
Section 3…………………………..Mythic™18 Fluidic
Section 4…………………………..Mythic™18 Electronic
Section 5…………………………..Mythic™18 Mechanic

01/09/2009 - 5 - Orphée S.A/M18/SEW/003
Section 1: Overview
Learning Objectives
Front view
Right side view
Rear view
Left side view
Physical specifications

01/09/2009 - 6 - Orphée S.A/M18/SEW/003
Learning objectives
Section 1 will provide and overview of the system and physical
dimensions of the Mythic™18.
After reviewing Section 1 of this workbook you should be able to do
the following:
Identify the connections located on the rear of the Mythic™18.
Connect the right reagents on the right connectors.
Identify the different fluidic module of the Mythic™18.

01/09/2009 - 7 - Orphée S.A/M18/SEW/003
Numerical
Keyboard
Status Indicator
LED
Power Switch
Start Cycle key
Mythic™18 – front view
LCD Display
touchscreen

01/09/2009 - 8 - Orphée S.A/M18/SEW/003
Mythic™18 – Right Side View
Counting module
Syringes module
Sampling module

01/09/2009 - 9 - Orphée S.A/M18/SEW/003
Mythic™18 – Rear View
Waste
connector
Diluent
connector
External
grounding
USB ports
TCP/IP port
Barcode
reader
RS232 port
Centronic port
24 V Power
supply
connector

01/09/2009 - 10 - Orphée S.A/M18/SEW/003
Mythic™18 – Left side view
Lyse solution
Straw
Cleaner Straw

01/09/2009 - 11 - Orphée S.A/M18/SEW/003
Mythic™18 – Physical Specifications
Physical dimensions
Dimension
Instrument
Height
350 mm
Width
250 mm
Depth
340 mm
Weight
11 kg
Note: For complete listing of physical specifications, refer to
Mythic™18 System Operator’s Manual.

01/09/2009 - 12 - Orphée S.A/M18/SEW/003
Section 2: User Interface
Learning Objectives.
Operator Screens.
Technician Screen.

01/09/2009 - 13 - Orphée S.A/M18/SEW/003
Learning Objectives
Section 2 will explain the user and service interface. After reviewing
this section of the workbook you should be able to do the following:
List the main menus of the instrument.
Describe how to use USB thumb drive.
Describe how to calibrate the instruments.
Describe how to restore Quality Control values.
Describe how to connect the SVM.
Describe how to check the pressure on the Mythic™18.
Describe where to adjust the electronic gains.

01/09/2009 - 14 - Orphée S.A/M18/SEW/003
Main Menu
START UP
Blank Cycle
SHUT DOWN
End of day Cycle
QUALITY CONTROL
QC
CALIBRATION
Automaton coef. adjust.
RESULT
Runs for checking
CHANGE
Target values
entry
RESULT
Runs for calibration
CHANGE
Target values entry
LJ
View Levey
Jennings
RESULT S
View chart results
RES
View RES number
selected
SET UP
SERVICE
CONTROL CYCLE
General Control
cycle
MECHANICS
Runs mechanical
control cycles
TECHNICIAN
Technician
functionalities
HYDRAULICS
Runs cleaning
cycles
CLEANING
BACKFLUSH
CHECK VALVES
RESET ALL
MOTORS
CHECK NEEDLE
CHECK ROCKER
CHECK SYRINGE
LOG ERRORS
Automaton status
reporting
DRAIN ALL
RINSE ALL
NEXT ID
RUN SA MPLE
Run and patient
identification
RUN
REAGENTS
Reagent functions
LOGS
Automaton diary
OPERATOR LOG OUT
Quit and launch new user
REPEATABILITY
Runs for
repeatability control
ADVANCED
(Biologist password)
PRINTER
OTHERS
SETTINGS
CALIBRATION
FACTORS
LAB.
PARAMETERS
ANLYSIS
OPTIONS
COMMUNICAT ION
LIMITS
THRESHOLDS
ALARMS
BLOOD TYPE
HGB LED OFF
BLEACH
CHANGE
LIMITS
THRESHOLDS
ALARMS
CORRECT . FACTORS
MOTOR INIT
Mechanic Control
cycle
Launch new menu
Launch Mechanical action
Entry menus
View Results
DILUENT
CYCLES COUNTER
LYSE
CLEANER
WASTE
PRIME ALL
CHANGE
REAGENT
PRIME
DILUENT
CHA NGE
REAGENT
PRIME LYSE
CHA NGE
REAGENT
RESET
PRIME
CLEA NER
Launch new menu
Launch Mechanical action
Entry menus
View Results
NEEDLE
DISMANTLING
LUBRICATION
POS.
CHECK SENSORS
INIT PRESS
VIEW
View full screen
history
Operator Screens –Main tree

01/09/2009 - 15 - Orphée S.A/M18/SEW/003
Operator Screens –Login
1- Password:
None : User –Lab tech
123 : Chief of lab
8SUP : Field Service Engineer
18ST : Super Technician
Note1: With 18ST password, everything is possible, no alert
message is displayed.
Note2: We recommend to use the 8SUP password during the
installation of a new instrument.
2- Language:
Choose the selected language with the scroll bar.

01/09/2009 - 16 - Orphée S.A/M18/SEW/003
How to use the USB key
The USB key must be formatted before any use. The format should be done
on the Mythic 18.
How to proceed?
1. Plug the USB key on
oOne of the two USB port for the Mythic 18 equipped with normal USB port.
oThe USB port on the lower position for the Mythic 18 equipped with small
USB port (like camera USB port).
2. Go to Set Up, Advanced menu, Storage Options.
3. Then, press USB thumb drive format.
4. When the format is finished a prompt will appear.
oIf the USB key is not compatible, a prompt will appear to inform you. In
this way, try another one.
NOTE: The format is done in FAT16. For this reason it is not necessary to
equip the Mythic 18 with a USB key with a capacity higher than 2 Gb.
2 Gb capacity = Around 60.000 patients.
128 Mb capacity = Around 10.000 patients.
Once your USB key is formatted, you can start to work with it.

01/09/2009 - 17 - Orphée S.A/M18/SEW/003
Overview of the main tree of the USB key:
The serial number of the Mythic 18 is coded as : xxxxxx-yyyyyy
These two groups of 6 digits will be used to create private folders, only usable on one
instrument.
Root folder for Mythic 18 analyser
Common folders. The content of this part
can be used on all Mythic 18 instruments.
NOTE: These folders must be created
manually, with Explorer Windows for
example.
All of these folders and datas contained in
these folders are dedicated to the
instrument and can’t be transfer to
another instrument.
Each folder is automatically created by the
Mythic 18.

01/09/2009 - 18 - Orphée S.A/M18/SEW/002
Folders description:
1/ Common datas
COMMONS DATAS : \ROOT\
(sub)Folder
files
contents
comments
Format and
unit
Analyser
Write/Read
LOT
MXC1234.QCN
MBC02174.QDL
(target name.Test_Level)
CAL0233.CAL
(target name.CAL)
Qc target values
Calibration target
values
One file per target
Limited at 100 files
ASCII
STD unit
NO / YES
SETTINGS
USER.SET
Common settings
One file
ASCII + UTF-8
YES / YES
UPDATE\
VERSION
V100-004.b
( version name.b)
Software release
One file per software release
binary
NO/YES
UPDATE\
PRTDRV
HP6122.LPT
(prn_name.port LPT or USB )
Printer drivers
One file per printer driver
binary
NO/YES

01/09/2009 - 19 - Orphée S.A/M18/SEW/002
2/ Mythic 18 dedicated data
PRIVATES DATAS : \ROOT\xxxxxx\yyyyyy\
(sub)Folder
Files name (example)
contents
comments
Format and
unit
Analyser
Write / Read
CALI
221006.CAL
(calibration date as
DDMMYY.CAL)
Calibration report =
calibration factors +
target + results
One file per calibration date
ASCII + UTF-8
current unit
YES / NO
LOG
LOG_ERR.CSV
LOG.CSV
Error log
service log
Two files
ASCII
YES / NO
QC
CRXV6875.QCN
(target name.level)
QC report =
target + results
One file per QC target and level
ASCII + UTF-8
STD unit
YES / YES
RESULTS\
YYYY-MM\
DD
0047.CSV
(sequence number. CSV)
Result analysis
One sub folder per Year/month (YYYY-
MM),
One sub folder per day (DD),
One file per result
Limited to 510 files
ASCII + UTF-8
current unit
YES / YES
SETTINGS
TECH.SET
Private analyzer settings
One file
ASCII + UTF-8
YES / YES
REAGENTS
REAGLOGS.CSV
Private reagents log
One file
ASCII
YES / YES

Mythic™18 Service engineer training workbook
01/09/2009 - 20 - Orphée S.A/M18/SEW/002
Once installed, you can use the USB key how you want.
Two cases:
5. The USB key is not connected on the instrument:
All the patient results will be saved on the internal memory of the instrument.
NOTE: The capacity of the internal memory is 1.500 patient results instead of 500 in the
previous version.
When the key will be locked on the instrument, the Mythic 18 will ask you if you want to
transfer the data on the USB. In this way, these data will be erased from the internal
memory.
6. The USB key is connected on the instrument:
If you have activated the option Real time runs save in the Storage Options, all the
results from the patient will be directly saved on the USB key.
NOTE: To avoid the problem of memory full, we recommend activating the option FIFO
Mode (First In, First Out) in the storage options. When the memory is almost full the first
result will be erased and replaced by the last one.
Other manuals for MYTHIC 18
2
Table of contents
Other Orphee Measuring Instrument manuals