OverTek OT-3407SVW User manual

4 Ports + 3 SFP Gigabit Smart Switch
User Manual
Ver.A0
OT-3407SVW/UX

DIRECTORY
Chapter 1 Product Specification
1.1 Product Characteristics
1.2 Product Specifications
1.3 Package Contents
Chapter 2 Hardware Installation
2.1 Quick Installation Guide
2.2 LED Indications
3.1 Fast Log on
3.2 System Configuration
3.3 Port Configuration
3.4 VLANs Configuration
3.5 Aggregation/Trunking Configuration
3.6 LACP Configuration
3.7 RSTP Configuration
3.8 802.1X Configuration
3.9 IGMP Configuration
3.10 Mirroring Configuration
3.11 Quality of Service Configuration
3.12 Filter Configuration
3.13 Rate Limit Configuration
3.14 Storm Control Configuration
4.1 Statistics Overview
4.2 Detailed Statistics
4.3 LACP Status
4.4 RSTP Port Status
4.5 IGMP Status
...................................1
..................................1
..................................1
.........................................3
...................................3
.................................3
............................................3
.....................................4
..................................................4
.....................................5
........................................5
.....................................6
.................6
.......................................7
.......................................7
.....................................8
.......................................8
.................................9
......................9
....................................10
.............................10
.........................11
........................................11
.....................................11
........................................11
..............................................12
........................................12
...............................................13
4.6 VeriPHY....................................................13
4.7 Ping.........................................................14
....................................14
Chapter 3 Configuration Guide
.............................................14
..........................................14
5.3 Software Upload
5.4 Configuration File Transfer
5.5 Logout
Chapter 6 Command Line Interface
6.2 Command Hierarchy
6.3 Login/Logout Procedures
6.4 Help Utility
6.5 Example
Chapter 7 Small Form Pluggable(SFP)
7.1 Specifications
7.2 SFP fiber optic module components description
7.3 SFP fiber optic transceiver module installation
7.4 How to plug out SFP optical modules?
7.5 Specification on fiber optic connection
7.6 Notes on optical used
7.7 Notes on optical connection
6.1 Com Port Set-up
..............................................15
................................15
..........................................................16
..............................16
.............................................16
........................................16
.................................16
....................................................17
.......................................................17
........................18
..................................................18
.....19
......19
.................20
................20
......................................21
..............................21
Chapter 4 Monitoring Guide
Chapter 5 Maintenance Guide
5.1 Warm Restart
5.2 Factory Default

Chapter 1 Product Specification
Complies with IEEE802.3,IEEE802.3u,IEEE802.3ab standards;
4 10/100/1000Mbps Auto-Negotiation RJ45 ports supporting
Auto-MDI/MDIX and 3 SFP independent expansion slots supporting
Mini GBIC module;
Supports Web Smart and console managements ;
Support IEEE802.3x flow control for half/full-duplex;
Store and forward, integrated 8K MAC address table;
Supports Port-Based /Tag VLAN Configuration;
Supports rapid spanning tree(RSTP) Configuration;
Supports Port Trunking;
Supports port bandwidth control;
Supports QoS function;
Supports port mirror;
Supports IGMP Snooping Configuration;
Supports SNMP Configuration;
Supports broadcast storm control;
Supports HTTP software update,backup and reseting;
Supports source IP filter through ports to block unwanted access;
Supports dynamic flow statistics of ports;
Supports circuit diagnoses;
Standard 11-inch rack-mountable steel case;
External power adapter supply;
1.2 Product Specifications
1.1 Product Characteristics
-1- -2-
Power: 100-240VAC 50-60Hz
Max:13W
Input
Consumption
Standards IEEE802.3, 802.3u, 802.3ab, 802.3x
Wire-speed Performance
MAC Address Auto-Learning and Auto-aging
IEEE802.3x flow control for Full-Duplex Mode
and backpressure for Half-Duplex Mode
32Gbps
8k
10BASE-T: 14880pps/port
100BASE-TX: 148800pps/port
1000BASE-T: 1488000pps/port
Basic Function
Backbound
Bandwidth
MAC Address Table
Forwarding Rate
Transmission Method Store-and-Forward
4 10/100/1000Mbps Auto-Negotiation RJ45
ports (Auto MDI/MDIX) and 3 SFP independence
expansion slots supporting MiniGBIC modules
Ports
EIA/TIA-568 100Ù STP (maximum 100m)
10Base-T: UTP category 3, 4, 5 cable
(maximum 100m)
EIA/TIA-568 100Ù STP (maximum 100m)
100Base-Tx: UTP category 5, 5e cable
(maximum 100m)
1000Base-T: UTP category 5, 5e cable
(maximum 100m)
Network Media
Power, 10/100M, 1000M
LED Indicators
250mm × 150mm × 44mm
Dimensions (W*D*H)
Storage Humidity: 5%~90% non-condensing
Operating Temperature: 0℃~40℃(32℉H~104℉H)
Storage Temperature: -40℃~70℃(-40℉H~158℉H)
Operating Humidity: 10%~90% non-condensing
Environment

1.3 Package Contents
Chapter 2 Hardware Installation
2.1 Quick Installation Guide
1 piece of 7-port Ethernet Switch
1 piece of external power adapter
1 piece of console cable
4 pieces of rubber padding
User's manual
Choose a proper place for the rack mountable switch, considering the
surroundings such as power source, space, keep it away from strong
sunlight, heat source, and electromagnetism interference.
Installation & Connection method:
1.Stick rubber paddings onto the bottom side of the switch.
2.Connect the switch to power source with offered power adapter,
turn it on, the switch will test itself, all its indication lights are on
at the same time, test is done when the lights go off after 5 seconds.
3.Connect the switch to network devices, including Lan cards,
switches etc. with Cat3,4,5 cable(Cat5 recommended); related
indication lights flash when attached network devices are working.
ALL ports support Uplink.
Note: Please not plug a phone line into a RJ45 port, otherwise it
may cause damage.
2.2 LED Indications
LED
Power
Link/Act
Speed
Status
ON/OFF
Flash
ON/OFF
ON/OFF
Indication
Power on/off
Ports connected/Ports unconnected
Data frames running
Maximum transmission rate 1000Mbps;
Maximum transmission rate 10/100 Mbps.
Chapter 3 Configuration Guide
3.1 Fast Log on
Notice: You may have to configure a new IP for a managing computer,
because default switch IP is 192.168.2.1. You can log on as
following steps:
1. Connect the switch with the managing computer Lan card;
2. Turn on the switch;
3. Make sure the managing computer IP address belongs to
192.168.2.2~254, e.g:192.168.2.100
4. Open IE browser , input http://192.168.2.1 and 'Enter', you will see
login window as below:
5. Input Password (no password in default), and click“Apply”,
configuration window comes as below:
-3- -4-

3.2 System Configuration
Here provides current switch status and you can set them according
to your demands.
MAC address:
Software Version :
Hardware Version :
Active IP Address:192.168.2.1(in default )
255.255.255.0(in default)
DHCP Server:0(in default)
Lease Time Left:0(default)
Here provides port status and available to set speed and flow
control; options to 10M half-duplex, 10M full-duplex, 100M
half-duplex,100M full-duplex, 1000M full-duplex, auto-negotiation
(in default) and disable.
3.3 Port Configuration
3.4 VLANs Configuration
Can set 16 VLAN groups for 802.1q VLAN
3.5 Aggregation/Trunking Configuration
-5- -6-

3.6 LACP Configuration
LACP(IEEE 802.3ad Link Aggregation Protocol) provides a way to set
up aggregation between switches automatically.
3.7 RSTP Configuration
RSTP is a protocol that prevents loops in a network and dynamically it
reconfigures to forward frames.
3.8 802.1X Configuration
Here provides 802.1X process and available to set for each port of the
switch.
3.9 IGMP Configuration
-7- -8-

3.10 Mirroring Configuration
Bandwidth of mirror port should be larger or equal to that of mirror
source.
3.11 Quality of Service Configuration
3.12 Filter Configuration
Set source IP filter through ports to block unwanted access.
3.13 Rate Limit Configuration
Policer/ShaperSpeed(options):128kbps, 256kbps, 384kbps,
512kbps, 640kbps, 768kbps, 836kbps, 896kbps, 1024Mbps,
1152kbps, 1280kbps, 1408kbps, 1536kbps, 1664kbps, 1792kbps,
1920kbps, 2048kbps, 2176kbps, 2304kbps, 2432kbps, 2560kbps,
2688kbps, 2816kbps, 2944kbps, 3072kbps, 3200kbps, 3328 kbps,
3456 kbps, 3584kbps, 3712kbps, 3840kbps and 3968 kbps.
-9- -10-

3.14 Storm Control Configuration
Broadcast Control speed(options): 1kfps, 2fps, 4fps, 8fps, 16fps,
32fps, 64fps, 128fps,256fps, 512fps, 1024fps, 2048fps, 4096fps,
8192fps, 16384fps, 32768fps.
4.1 Statistics Overview
Here provides statistics of current forwarding and receiving data.
Chapter 4 Monitoring Guide
4.2 Detailed Statistics
Here provides detailed statistics of current forwarding and receiving
data.
4.3 LACP Status
Here provides LACP port Status.
4.4 RSTP Port Status
Here provides RSTP port Status.
-11- -12-

4.5 IGMP Status
Here provides IGMP Status.
4.6 VeriPHY
4.7 Ping
Ping function is used to test connection between the switch and
destination.
Chapter 5 Maintenance Guide
5.1 Warm Restart
Warm Restart : click “Yes” to start restart the switch.
5.2 Factory Default
Restore Factory Configuration: click “Yes” to default factory
configuration.
NOTICE: Please do login the switch window again after this
configuration. please use a new IP address as you set, if you
changed its default IP address before.
-13- -14-

5.3 Software Upload
Update process takes about 1 minute, the switch reboots
automatically after software being updated, and re-login is required.
5.4 Configuration File Transfer
Configuration File upload and download
5.5 Logout
Please finally logout to make sure system security.
Chapter 6 Command Line Interface
6.1 Com Port Set-up
To use the command line interface you may connect a PC COM port
to the RS-232 connector and activate a terminal program, e.g.
HyperTerminal under Windows. The COM port must be set up to run
8 data bits, 1 stop bit, no parity, 115200 baud and without flow control.
6.2 Command Hierarchy
The CLI is hierarchical with two levels: a top level and a group level.
The group level consists of the following Groups: System ,Console,
Port, MAC,VLAN, Aggregation, LACP, RSTP, User Group, QoS,
Mirror, IP,Dot1X, Debug .
At top level you may enter a command by giving the full command
string, including group, or you may change context into a group by
entering the name of the group.
At group level you may enter commands for the particular group you
have chosen without specifying the group name or you may return to
thetop level by entering the up command.
The current level and group is indicated by the prompt. If you are at
the top level, the prompt will be:
>If you are at group level, the prompt will display the actual group,
e.g. System.
>At group level you also have the option of using the slash (/) key to
referto a context relative to the top level. E.g. you may be in the
system group and enter a /console/configuration command or change
context into the console group by entering /console.
6.3 Login/Logout Procedures
To get access to the CLI you must login by entering a password. You
will automatically be queried about the password.The password is
configurable. The password check may be disabled by setting the
password to an empty string “”, in which case any password entered
during login will be accepted.
You may logout at any time and at any context level using the “exit”
command.
-15- -16-

6.4 Help Utility
You may get help by pressing the ? key or entering “help”. The help info
depends on the context:
At top level, a list of command groups is displayed.
At group level, a list of the command syntaxes for the current group is
displayed.
If the help command is issued for a specific command, the command
syntax and a description of the command are shown.
6.5 Example
The command hierarchy and the help utility is demonstrated in the
following example:
> ? <enter>
Commands at top level:
System – System commands
Console – Console commands
Port – Port commands
MAC – MAC table commands
VLAN – VLAN commands
Aggregation – Aggregation/Trunking commands
LACP – IEEE802.3ad Link aggregation commands
RSTP – IEEE802.1w Rapid Spanning Tree commands
User Group – User Group commands
QoS – QoS commands
Mirror – Mirror commands
IP – IP commands
Dot1x – Dot1x commands
Debug – Debug commands
> console <enter>
Console> ? <enter>
Commands at Console level:
Console Configuration
Console Password [<password>]
Console Timeout [<timeout>]
Console Prompt [<prompt string>]
Console> password ?
Syntax:
Console Password [<password>]
Description:
Set or display console password. The empty string (“”) disables the
password check.
[<password>]: Password string of up to 16 characters.
Console>
Chapter 7 Small Form Pluggable(SFP)
7.1 Specifications
Optical transceivers support gigabit single/multi-mode, and transfer as
far as 80 kms distance; original SFP modules are recommended to be
used. Supportable optical transceivers are listed as following:
SFP-GIG-SX
Gigabit Ethernet optical transceiver(supports
850nm wavelength multi-mode, LC connector).
Up to 550 meters through 50/125μm multi-mode
fiber, and up to 275 meters through 62.5/125μm
multi-mode fiber.
Gigabit Ethernet optical transceiver(LC connector).
Up to 10 kms through 1310nm wavelength single
-mode fiber.
Gigabit Ethernet optical transceiver(LC connector).
Up to 40 kms through1310nm wavelength single
-mode fiber.
Gigabit Ethernet optical transceiver(LC connector).
Up to 80 kms through 1550nm wavelength single
-mode fiber.
SFP-GIG-LX
SFP-GIG-LH40
SFP-GIG-LH80
-17- -18-

7.2 SFP fiber optic module components description
SFP fiber optic module specification label
Incoming optical signal jack
Outgoing optical signal jack
Protective sliding rod
Protective shield
1
2
3
4
5
7.3 SFP fiber optic transceiver module installation
Step 1 Remove protective package and its protective shield
Step 2 With the correct way to hold the SFP optical module, and insert
it into a slot and in place
Step 3 Insert it with right fiber optic cable. Matching fiber optic cables
according to spec label are required to avoid of possible damage,
and to get maximum effective transmission distance of optical
signal.
Step 4 Connect to network clients and insure correct working status by
checking indication lights.
7.4 How to plug out SFP optical modules?
7.5 Notes on SFP optical module use
Right fiber cables with LC connector to be adopted, and 1000M
standard SFP module used.
-19- -20-

7.5 Specification on fiber optic connection
LC connector Limit shrapnel
1 2
7.6 Notes on optical used
Please do not directly look at optical interface when no optical
connectors or dust covers fixed on, because invisible rays from it
may hurt eyes.
Fix it with a dust cover when no optical connectors connected.
Right connectors and optical cables are chosen before connection
7.7 Notes on optical connection
Do not excessively bend optical cables.
Be sure of that Tx of interface is connected to Rx of its opposite end,
and Rx to Tx of its opposite end.
Be sure of cleanliness of optical interfaces
-21- -22-
This manual suits for next models
1
Table of contents
Popular Switch manuals by other brands

Siqura
Siqura XSNet S4124SW quick start guide

Dell EMC
Dell EMC PowerSwitch N3200-ON Series installation guide

Shelly
Shelly PRO 4PM user manual

Korenix
Korenix JetNet 5710G Series Quick installation guide

Mitsubishi Electric
Mitsubishi Electric DT125TXA user manual

TRENDnet
TRENDnet TEG-424WS Quick installation guide