OXE 3,5" Display User manual

DRAFT 5
DRAFT 5
1
OXE 200 HP 3.5” DISPLAY MANUAL
3.5”-DISPLAY MANUAL
Publication No: ODM 1012
DIESEL ENGINE


DRAFT 5
3
OXE 200 HP 3.5” DISPLAY MANUAL
CONTENTS
About this manual _______________________________________________________________________ 5
Installation procedure ____________________________________________________________________ 6
3.5” monitor measurements___________________________________________________________ 6
Mounting 3.5” display ________________________________________________________________ 7
Connecting the 3.5” Display ___________________________________________________________ 8
Display description ______________________________________________________________________ 9
Screen settings _____________________________________________________________________ 9
Buttons ___________________________________________________________________________ 9
Function description ____________________________________________________________________ 10
Config menu ______________________________________________________________________ 10
Screen 1 _________________________________________________________________________ 13
Screen 2 _________________________________________________________________________ 14
Screen 3 _________________________________________________________________________ 15
Screen 4 _________________________________________________________________________ 16
Updating the 3.5” display ________________________________________________________________ 17
Trouble shooting ___________________________________________________________________ 18
CONTENTS

DRAFT 5
4
OXE 200 HP 3.5” DISPLAY MANUAL

DRAFT 5
DRAFT 5
5
OXE 200 HP 3.5” DISPLAY MANUAL
INTRODUCTION
ABOUT THIS MANUAL
This manual provides you with the information you need to install the display,
know about Display key function, readings and fault codes.
Specifications and descriptions are subject to change without notice.
Cimco Marine AB
Metallgatan 19a
SE-262 72 Engelholm, Sweden
+46 (0)431-371130

DRAFT 5
6
OXE 200 HP 3.5” DISPLAY MANUAL
INSTALLATION PROCEDURE
3.5” MONITOR MEASUREMENTS
NOTE! If you intend to photocopy the following mounting template for use, check ALL measurements using a
measuring device prior to using as a template.
INSTALLATION PROCEDURE
Ø 3.34"
[84.836 mm]
0.80"
[20.32 mm]
0.120"
[3.048 mm]
2.07"
[52.578 mm]
3.75" OUTLINE
[95.25 mm]
3.75" OUTLINE
[71.628 mm]
3.33" OPEN BEZEL
[84.582 mm]
2.82" VIEWING DISPLAY
[71.628 mm]
2.82" VIEWING
DISPLAY
[71.628 mm]
3.33" OPEN
BEZEL
[84.582 mm]

DRAFT 5
7
OXE 200 HP 3.5” DISPLAY MANUAL
INSTALLATION PROCEDURE
MOUNTING 3.5” DISPLAY
Measures for flush-mounted display
NOTE! If you intend to photocopy the following mounting template for use, check ALL measurements using a
measuring device prior to using as a template.

DRAFT 5
DRAFT 5
8
OXE 200 HP 3.5” DISPLAY MANUAL
Measures for dash board cut-out
NOTE! If you intend to photocopy the following mounting template for use, check ALL measurements using a
measuring device prior to using as a template.
CONNECTING THE 3.5” DISPLAY
Connecting diagrams are available in the Installation Manual.
INSTALLATION PROCEDURE

DRAFT 5
DRAFT 5
9
OXE 200 HP 3.5” DISPLAY MANUAL
DISPLAY DESCRIPTION
DISPLAY DESCRIPTION
SCREEN SETTINGS
Contrast
Brightness Return
to screen
BUTTONS
The 3.5” Monitor is easily operated by means of only three buttons.

DRAFT 5
10
OXE 200 HP 3.5” DISPLAY MANUAL
FUNCTION DESCRIPTION
CONFIG MENU
The config menu page is accessed by pressing and holding the fih button from the le for a few seconds.
The following options are available in the config menu:
- Demo ON/OFF
- Settings
- Number of engines installed
- Engine No.
- Unit system
- Fuel sender
- Bleep ON/OFF
- Diagnostic tools
- Restore defaults
- About
FUNCTION DESCRIPTION

DRAFT 5
11
OXE 200 HP 3.5” DISPLAY MANUAL
SETTINGS
Number of engines
This setting represents how many engines are connected to the CAN bus. This is the TOTAL number of engines.
When using 3.5” displays, each engine requires a separate display. This setting must be correct and match what
is configured in the Engine Control Unit (ECU). Entering the wrong setting may result in errors and false data
being displayed. For single engine installations this should always be set to 1.
Engine No.
This setting represents what engine this display should connect to. For single engine installations this should
always be set to 1.
Unit system
Metric or Imperial.
Metric will display data in kPa and °C
Imperial will display data in psi and °F
Fuel sender
The display can handle three types of fuel senders.
- European standard analogue sender (0-190 Ω)
- US standard analogue sender (240-30 Ω)
- NMEA2000 digital signal over CAN bus
The analogue senders should be connected with one pin to ground and one to pin 7 on the secondary connector
at the back of the display.
Bleep
Turn button sound on/off.
Display screen ID
Enable/disable display of identifying number when switching to screen 1, 2 or 3.
FUNCTION DESCRIPTION

DRAFT 5
12
OXE 200 HP 3.5” DISPLAY MANUAL
BRIDGE TO CAN 2
Bridge to CAN2 is used to forward engine data to another CAN network.
- Forwards selected groups of engine data to another CAN network.
- Requires display cable with an additional CAN connector.
There are a number of data groups that can be forwarded. All but the “Trolling”
group are standard NMEA 2000 or J1939 messages.
Diagnostic tools
Provides tools for diagnosing the ports.
Restore defaults
Loads default settings
- Metric system
- No fuel sender
- 1 engine
- Engine 1 of 1
- LCD backlight to max
- Demo OFF
- Bleep ON
- Disp. screen ID ON
Demo
Enabling demo will auto generate display data. All data is internal in the display
and nothing is sent on the CAN bus.
About
Soware version number and other display data.

DRAFT 5
DRAFT 5
13
OXE 200 HP 3.5” DISPLAY MANUAL
SCREEN 1
Screen 1 displays information information about
- Engine speed
- Engine oil pressure
- Engine coolant temperature
Additionally the screen displays
- Total engine hours
- Trim angle
- Gear

DRAFT 5DRAFT 5
14
OXE 200 HP 3.5” DISPLAY MANUAL
FUNCTION DESCRIPTION
SCREEN 2
The following is displayed on screen 2
- Boost pressure meter
- Oil temperature meter
- Exhaust temperature meter
Additionally the screen displays
- Engine speed
- Total engine operating hours
- Trim/Tilt
- Gear
Gear
Trim angle
Press for
previous
screen Press for
next screen
Engine speed Total operating hours
Boost pressure
Exhaust
temperature
Engine oil
temperature
Fuel
indicator
Low speed
function

DRAFT 5
DRAFT 5
15
OXE 200 HP DISPLAY MANUAL
FUNCTION DESCRIPTION
SCREEN 3
Screen 3 provides the overall information from Screen 1 and Screen 2 in words.

DRAFT 5
16
OXE 200 HP 3.5” DISPLAY MANUAL
FUNCTION DESCRIPTION
SCREEN 4
Screen 4 displays error codes.
When an error is detected the little green dot in the upper right corner switches its colour to orange or red,
depending on severity.
An orange dot indicates a warning. A red dot indicates a more serious error. In addition to the dot changing
colour, button four is lit with the word Warning (in orange) or Error (in red) displayed.
Pressing the Error-button switches the display to a list with fault codes. The fault codes are explained in the
Service Manual.

DRAFT 5
17
OXE 200 HP 3.5” DISPLAY MANUAL
UPDATING THE 3.5” DISPLAY
UPDATING THE 3.5” DISPLAY
NOTE! We recommen that an update of the soware is performed by an authorized technician.
Please contact your dealer.
USB PORT
The 3.5” display is updated using a USB memory stick which is inserted in the USB port found at the back of the
display.
If you have been provided with a pre loaded USB stick you can skip the section preparing the USB Memory stick
and go directly to the next section.
Preparing the USB stick
- Use a standard USB memory stick formatted as FAT32 file system.
- Insert the memory stick into your PC.
- Unzip the usbupdate_PROJECTNAME.zip.
NOTE! Please note that you should only copy the files inside the usbupdate_PROJECTNAME.zip file to the
root of the USB memory stick and not the zip file itself.
- Copy the unzipped contents of the usbupdate_PROJECTNAME.zip to the previously blank memory stick
Applying the update
- Power up the 3.5” display and wait for the installed application to run, then plug the USB stick into the rear
USB connector.
- The USB Stick will be automatically detected and the update process will begin.
- Wait for the on-screen prompts before removing the USB Stick, once removed, the unit will reboot.
- The unit will now be updated with the latest firmware and your latest applications.

DRAFT 5
18
OXE 200 HP 3.5” DISPLAY MANUAL
TROUBLE SHOOTING
If a 3.5” display will not boot, ensure that the power is OFF.
Insert the USB Stick into the USB Port. Turn on the power while simultaneously
holding down Key 1 and Key 5. The screen will turn BLUE and aer a few seconds
the update process will begin. There will be on-screen information during the
update process. Please remove the USB Stick when prompted and the target unit
will automatically reboot into the new soware.
NOTE! If the screen turns RED at any point during the update process, aer the
BLUE screen has been shown, there were problems reading the information
on the USB Memory Stick. This indicates that the soware update has not been
applied.
NOTE! Some USB Memory Sticks are not compatible with the target unit. If the
update does not install properly, please try a USB Memory Stick from a different
manufacturer.
Aer testing all available USB Memory Stick models from SanDisk we found them
all working without issues.
UPDATING THE 3.5” DISPLAY

DRAFT 5
DRAFT 5
19
OXE 200 HP 3.5” DISPLAY MANUAL

DRAFT 5
20
OXE 200 HP 3.5” DISPLAY MANUAL
Cimco Marine AB, Metallgatan 19 A Ängelholm, SE-262 72 Ängelholm, SWEDEN
+46 (0)431-37 11 30, www.oxe-diesel.com
Printed in Sweden 2016. Copyright © 2016 Cimco Marine AB.
Table of contents