550 /550T / 1100/ 1100T operation and maintenance instructions
IMPORTANT!!!!!
1. Read instructions thoroughly before operating!!
2. After shipping the unit via courier or after rough handling such as falling off a shelf open cabinet by following
step 1 of the cleaning instructions. Check to make sure the UV tubes are in place. If the tubes have come out of
place, re install them. If they are broken, wearing rubber gloves clean the glass out and replace the tubes.
CAUTION, THIS OZONE GENERATOR PRODUCES DANGEROUS ULTRAVIOLET LIGHT,
DISCONNECT POWER BEFORE OPENING TO SERVICE
SPECIFICATIONS FOR 550 & 1100T SERIES OZONE GENERATOR
Maximum output 550:(550mg/hr) / 1100T:(1100mg/hr)
Fan (rated cfm) 105 cfm
Filter 1 Cleanable foam filters
Cabinet material PVC outer cabinet with stainless steel inner chassis
Generation method Ultraviolet Light
Weight and size 550:(10lb) / 1100T:(12.6lb) 23" long x 5 wide x 6 5/8 height (including handle)
INTRODUCTION
This line of ozone generators are designed for various uses. This ozone generator can be used for many uses such
as deodorizing cars homes as well as oxidizing many organic contaminants.
WARRANTY (please refer to complete warranty attached)
The 550 is warranted against defects in materials and workmanship for a period of 6 years from date of purchase.
Liability is limited to parts and labor only. Shipping is the sole responsibility of the customer. CAPS is not liable
for damage caused by shipping, misuse, neglect or lack of regular maintenance.
LIABILITY
CAPS assumes no responsibility for any damage done to items from the use or miss use of any product sold or
manufactured by CAPS . It is the customers responsibility to test materials prior to use and to ensure that the
procedure and installation technique they are using is correct for the application.
HEALTH AND SAFETY
Ozone can be an irritant and a powerful oxidizing agent. As with most all products, ozone is dangerous only when
used improperly, as such it is important to follow safe usage guide lines.
*When doing a shock treatment, no people plants or pets/animals may be in the room when the unit is running.*
The room should not be re entered until all ozone has been depleted unless proper breathing respirators are used.
MAINTENANCE FREQUENCY
Under heavy duty use or severely polluted areas, The ozone generator filter should be inspected and cleaned if
necessary every 2 to 3 weeks. Inspect the UV tubes for fine dust or residue collecting on UV generator tube
surfaces. Light duty use requires cleaning every 2 to 6 months depending on the severity of pollution in the feed
air. In dirty conditions cleaning can be as often as 4-6 weeks.
DESCRIPTION OF OZONE GENERATOR
These ozone generators produce ozone by UV light, converting normal oxygen to ozone gas which is a very strong
oxidizing agent used to destroy odors and other organic contaminants.
PLACEMENT OF UNIT
This ozone generator is designed as a portable commercial deodorizing device. It uses 120VAC for North America,
and 220-240VAC for European countries etc. European models come with an IEC connector and it is up to the
customer to supply the proper cord (this can be acquired at any computer shop).
Please note the following points when placing the unit.
-Place on a flat solid surface such as a table or shelf. Do not place on rug flooring to reduce dust entering the unit
-Do not place in an area where the unit could be splashed with water, moisture or in an area that it could get
flooded with water.
-Ensure that the unit gets proper fresh air flow. Do not obstruct the incoming or outgoing air from the unit.
-If used in temperatures below freezing, ensure that condensation inside the unit does not occur.
-Set the unit in an area where it will provide the best ozone distribution.
-The use of circulation fan will greatly increase the efficiency of the treatment.
-If the ozone generator being used is large enough to treat the whole house, the air handling system can be used
to distribute the ozone, just point the ozone generator into the return air duct of the air handler, and turn the fan
on to run constantly (summer fan setting on most furnaces).