
Panasonic North America
Air Conditioning Division
1690 Roberts Blvd., NW, Suite 110
Kennesaw, GA 30144
http://www.panasonic.com/aircon
Press the remote control’s button
1TO TURN ON OR OFF THE UNIT
• Please be aware of the OFF indication on the
remote control display to prevent the unit from
starting/stopping improperly.
2TO SET TEMPERATURE
• Selection range: 60°F ~ 86°F.
3TO SELECT OPERATION MODE
AUTO mode - For your convenience
• Unit selects operation mode during startup
according to temperature setting and room
temperature.
HEAT mode - To enjoy warm air
• Unit takes a while to warm up. The power
indicator blinks during this operation.
COOL mode - To enjoy cool air
• Use curtains to screen off sunlight and outdoor
heat to reduce power consumption during cool
mode.
DRY mode - To dehumidify the environment
• Unit operates at low fan speed to give a gentle
cooling operation.
4TO SELECT FAN SPEED
(Remote control display)
FAN SPEED
• For AUTO, the indoor fan speed is
automatically adjusted according to the
operation mode.
5TO ADJUST VERTICAL AIRFLOW
DIRECTION
(Remote control display)
AIR SWING
• Keeps the room ventilated.
• In COOL/DRY mode, if AUTO is set, the louver
swing up/down automatically.
• In HEAT mode, if AUTO is set, the horizontal
louver fixed at predetermined position.
• For Hide-Away models, AIR SWING buttons
are not in use. Airflow direction can not be
adjusted.
6
Press and hold for approximately 10
seconds to show temperature setting in °C
or °F.
7Press and hold for 5 seconds to dim or
restore the unit’s indicator brightness.
8Press to restore the remote control’s
default setting.
9RETRIEVE ERROR CODE
• During operation, the unit stops and both a
and bis OFF indicates abnormality occurs.
1.Ensure ais OFF, press for 5 seconds.
2.Press or . If error code and abnormality
can be identified, awill be ON continuously,
then write down the error code.
3.Press for 5 seconds to quit checking.
4.Turn the unit off and reveal the error code to
authorized dealer.
Note: Press for 10 seconds to enter AC reset
switch (Not used in normal operation).
10 AIR FILTER MAINTENANCE
Cleaning is needed when “FILTER CHECK”
indicator is ON.
• lt is recommended to clean the air filter every 6
weeks.
• After the air filter is cleaned, press to
reset.
• Do not operate without an air filter.
• Wash/rinse the filters gently with water to avoid
damage to the filter surface.
• Do not dry the part with a hair dryer or a stove.
• Replace any damaged filters.
11 TO SWITCH BETWEEN POWERFUL &
QUIET
POWERFUL/
QUIET
QUIETPOWERFUL NORMAL
POWERFUL: To reach temperature quickly
• This operation stops automatically after 20
minutes.
QUIET: To enjoy quiet operation
• This operation reduces airflow noise.
Data is Subject to Change.