paratronic LHC User manual

I179EN - 1021
1/16
PARATRONIC - Rue des Genêts - Zone Industrielle - 01600 REYRIEUX - FRANCE
Tel.: +33 (0)4 74 00 12 70 – Fax: +33 (0)4 74 00 02 42 - E-Mail: [email protected] - Web: http://www.paratronic.com
LHC and LHM
LEVEL AND TEMPERATURE SENSOR / RECORDER /
TRANSMITTER

I179EN - 1021
2/16
PARATRONIC - Rue des Genêts - Zone Industrielle - 01600 REYRIEUX - FRANCE
Tel.: +33 (0)4 74 00 12 70 – Fax: +33 (0)4 74 00 02 42 - E-Mail: [email protected] - Web: http://www.paratronic.com
Contents
1 SAFETY INSTRUCTIONS ........................................................................................................... 3
2 DESCRIPTION ........................................................................................................................... 3
3 MODELS and options ................................................................................................................. 3
4 SPECIFICATIONS ...................................................................................................................... 4
4.1 Recorder module: ..................................................................................................................... 4
4.2 Sensor: .................................................................................................................................... 4
5 DIMENSIONS ............................................................................................................................ 6
5.1 LHC or LHM recorder module: ........................................................................................................... 6
5.2 Antennas: .......................................................................................................................................... 6
5.3 Sensor: .............................................................................................................................................. 7
6 INSTALLATION .......................................................................................................................... 7
6.1 Precautions for installation and use: ........................................................................................... 7
6.2 Connecting the whip antenna to the LHC: ................................................................................... 8
6.3 Installing the pad antenna and connecting it to the LHC: .............................................................. 8
6.4 Mounting the probe cable safety coupling lug on the LHC: .......................................................... 10
6.5 Connecting the SFP probe to the LH(C/M): ............................................................................... 10
6.6 Inserting the SIM card in the LHC: ............................................................................................ 11
6.7 Replacing the LH(C/M) battery: ................................................................................................ 13
6.8 Connecting the LH(C/M) via USB: ............................................................................................ 15
6.9 Replacing the desiccant sachet (silica gel to protect against moisture): ........................................ 15
6.10 Mounting the LH(C/M) on-site: ................................................................................................. 16

I179EN - 1021
3/16
PARATRONIC - Rue des Genêts - Zone Industrielle - 01600 REYRIEUX - FRANCE
Tel.: +33 (0)4 74 00 12 70 – Fax: +33 (0)4 74 00 02 42 - E-Mail: [email protected] - Web: http://www.paratronic.com
1 SAFETY INSTRUCTIONS
: Hazard risk. Important information. Refer to the instructions for use.
: Read the instructions for use.
: Compliant with European Union and EFTA directives.
: European Directive 2002/96/EC of 27 January 2003 on waste electrical and electronic equipment
(WEEE Directive) was transposed in France by Decree No. 2005-829 of 20 July 2005.
Electrical or electronic appliances, and their spare parts and consumables must never be disposed of in
household waste.
PARATRONIC has undertaken to set up an Individual Collection System.
PARATRONIC waste electrical and electronic equipment should be returned by customers (End users) to
our company’s head office, at the following address:
PARATRONIC – Service DEEE - Zone Industrielle - Rue des Genêts, 01600 REYRIEUX, France
: WARNING: The protection offered may be compromised if this appliance is not used as
specified.
2 DESCRIPTION
The LHC and LHM models consist of a recorder module (which, for the LHC model, incorporates a
modem) and a probe (ref. SFP).
As standard, a “whip” type antenna is provided with LHM models.
They are designed for standalone water level and water temperature measurement. Particularly
suitable for drilling hole and piezometer measurement, they can be configured using
the “IHM Capteurs” from PARATRONIC (see : instructions I158F).
3 MODELS AND OPTIONS
SFP probes: These probes are used for level (pressure) and temperature measurement. Several
measurement ranges are available:
SFP 10: measurement range 0 – 10m
SFP 40: measurement range 0 – 40m
SFP 90: measurement range 0 – 90m
SFP 150: measurement range 0 – 150m
The cable length is defined when ordering.

I179EN - 1021
4/16
PARATRONIC - Rue des Genêts - Zone Industrielle - 01600 REYRIEUX - FRANCE
Tel.: +33 (0)4 74 00 12 70 – Fax: +33 (0)4 74 00 02 42 - E-Mail: [email protected] - Web: http://www.paratronic.com
LH(C/M) recorder modules: These are units including the power battery, recorder and, optionally,
the modem. Two models are available:
LHM: version without modem.
LHC: version with integrated modem.
Antennas for LHC: The LHC model includes a 2G / GPRS / 3G modem and therefore needs to be
connected to an antenna. There are two antenna types:
Whip antenna: supplied as standard with each LHC.
“Pad” antenna: antenna supplied as an option.
4 SPECIFICATIONS
4.1 RECORDER MODULE:
Memory capacity >= 500,000 measurements.
Power supply 6.0V 12.5Ah lithium battery, replaceable by the user.
Battery life > 10 years (1 measurement/hour, 1 transmission/week).
PC connection Micro-USB connector.
Antenna connection TNC connector (LHC version).
SFP connection 3-pin connector.
Operating temperature - 20°C to + 60°C.
Storage temperature - 20°C to + 60°C.
Fast transients EN 61000-4-4: Level 3.
Surge immunity EN 61000-4-5: 6KV.
Standards: (CE Mark) EN 61326-1, Immunity: industrial environment, Emission: class B, EN
61010-1, EN 62479, EN 50581.
Protection rating IP67
Body dimensions diam. 79mm (stop), diam. 50mm (tube), Length = 403mm without
antenna.
With whip antenna: 453 mm.
Weight 1490g.
Body material 304L stainless steel.
4.2 SENSOR:
Pressure measurement:
Measurement range 0 – 10m, 0 – 40m, 0 – 90m, 0 – 150m.
Resolution 1mm.
Precision +/-0.05% of full scale (SFP10, 90, 150)
+/-0.1% of full scale (SFP40)
Temperature measurement:
Resolution 0.1°C.
Precision +/-0.5°C.

I179EN - 1021
5/16
PARATRONIC - Rue des Genêts - Zone Industrielle - 01600 REYRIEUX - FRANCE
Tel.: +33 (0)4 74 00 12 70 – Fax: +33 (0)4 74 00 02 42 - E-Mail: [email protected] - Web: http://www.paratronic.com
Operating temperature -20°C to + 60°C (in liquid phase).
Storage temperature -20°C to + 60°C (in liquid phase).
Fast transients EN 61000-4-4: Level 3.
Surge immunity EN 61000-4-5: 6KV.
Standards: (CE Mark) EN 61326-1, Immunity: industrial environment, Emission: class B,
EN 61010-1, EN 62479, EN 50581.
Protection rating IP68 permanent duration.
Body dimensions diam. 21.5mm, Length = 116mm.
Weight 150g + 60g per metre of cable.
Probe body material 316L stainless steel.
Cable Ø 7mm +/-0.5mm Length: on request.
Use Connected and coupled to LH(C/M) recorder.
As per ISO 4373 standard Physical principle of the device: pressure measurement by
submersion
Maximum variation rate: not applicable
Response time: 500 ms
Model
Performance class
Temperature class
Relative humidity class
SFP 10
3
2
1
SFP 40
1
2
1
SFP 90
1
2
1
SFP 150
1
2
1
IP rating: IP68
Drinking water compatibility: no
Explosive environment compatibility: no

I179EN - 1021
6/16
PARATRONIC - Rue des Genêts - Zone Industrielle - 01600 REYRIEUX - FRANCE
Tel.: +33 (0)4 74 00 12 70 – Fax: +33 (0)4 74 00 02 42 - E-Mail: [email protected] - Web: http://www.paratronic.com
5 DIMENSIONS
5.1 LHC OR LHM RECORDER MODULE:
403
301
Ø50
Ø79
17
5.2 ANTENNAS:
Whip:
66mm
16mm
Pad:
144mm
14mm
35mm
13mm
16m
m
14m
m
35m
m
13m
m
66m
m
144m
m

I179EN - 1021
7/16
PARATRONIC - Rue des Genêts - Zone Industrielle - 01600 REYRIEUX - FRANCE
Tel.: +33 (0)4 74 00 12 70 – Fax: +33 (0)4 74 00 02 42 - E-Mail: [email protected] - Web: http://www.paratronic.com
5.3 SENSOR:
11635
Ø21.5
Ø7 Ø10
LH(C) SFP
6 INSTALLATION
The LH(C/M) sensor can, depending on the options selected, be supplied with (LHC) or without
(LHM) an antenna, and with or without a mounting bracket (ref. “LH EQUERRE”). For the LHC, the
antenna supplied as standard is a “whip” antenna; as an option, a “pad” antenna can be supplied
(ref. “LH ANTGAL”). Therefore, different mounting and assembly possibilities are available
according to the equipment and options selected.
6.1 PRECAUTIONS FOR INSTALLATION AND USE:
The recorder module (LH(C/M)) and its associated probe (SFP) are measuring instruments.
Therefore, they must be handled with caution and care. All transportation must be carried out in the
original packaging.
Products must not receive shocks and must not be subjected to severe pressure or temperature
variations.
The probe measurement cell is an active and sensitive component. For this reason, the probe must
be set up (submerged) with caution. Pressure must never be exerted on the cell with a tool, and the
cell must never be cleaned with a corrosive substance. In the event of fouling, it is recommended to
simply rinse with water.
The LH(C/M) recorder module makes an atmospheric pressure measurement. The pressure
measuring port is located on the bottom of the module, next to the connector intended for the
sensor. Please ensure that this port is never blocked.
Always respect the temperature and pressure operating limits associated with the model used
(refer to the “SPECIFICATIONS” section).
LH (C)
SFP

I179EN - 1021
8/16
PARATRONIC - Rue des Genêts - Zone Industrielle - 01600 REYRIEUX - FRANCE
Tel.: +33 (0)4 74 00 12 70 – Fax: +33 (0)4 74 00 02 42 - E-Mail: [email protected] - Web: http://www.paratronic.com
6.2 CONNECTING THE WHIP ANTENNA TO THE LHC:
Position the whip antenna opposite the metallic connector of the LHC:
Fasten the antenna onto the connector using the ring provided for this purpose:
6.3 INSTALLING THE PAD ANTENNA AND CONNECTING IT TO THE LHC:
The pad antenna should be mounted on a horizontal surface. For this purpose, drill a 15mm
diameter hole in the surface selected.
Insert the antenna cable, without damaging it, into the hole:

I179EN - 1021
9/16
PARATRONIC - Rue des Genêts - Zone Industrielle - 01600 REYRIEUX - FRANCE
Tel.: +33 (0)4 74 00 12 70 – Fax: +33 (0)4 74 00 02 42 - E-Mail: [email protected] - Web: http://www.paratronic.com
Fasten the antenna mounting component:
Position the pad antenna connector opposite the metallic connector of the LHC:
Fasten the pad antenna connector to the metallic connector of the LHC:

I179EN - 1021
10/16
PARATRONIC - Rue des Genêts - Zone Industrielle - 01600 REYRIEUX - FRANCE
Tel.: +33 (0)4 74 00 12 70 – Fax: +33 (0)4 74 00 02 42 - E-Mail: [email protected] - Web: http://www.paratronic.com
6.4 MOUNTING THE PROBE CABLE SAFETY COUPLING LUG ON THE LHC:
Unfasten the lug mounting screw using a 3mm hex key:
Fit the coupling lug and refasten the mounting screw:
6.5 CONNECTING THE SFP PROBE TO THE LH (C/M):
Insert the SFP probe connector into the socket of the LH(C/M):
This manual suits for next models
1
Table of contents
Popular Temperature Controllers manuals by other brands

SMC Networks
SMC Networks Thermo-con INR-244-639 Operation manual

eltherm
eltherm Ex-TC It Series operating instructions

Omron
Omron C200H-TV Series Operation manual

industrie technik
industrie technik CA1 instructions

KRAL
KRAL EET 32 operating instructions

dixell
dixell XR420C Installing and operating instructions