Paris Rhone PE-AH009 User manual

STATEMENT
SAFETY INSTRUCTIONS
BEFORE USING THE HUMIDIFIER
WHEN USING THE HUMIDIFIER
AFTER USING THE HUMIDIFIER
PACKAGE CONTENTS
SPECIFICATIONS
PRODUCT DIAGRAM
OPERATIONS AND FUNCTIONS
Add Water
Add Essential Oil (Optional)
Control Buttons
Remote Control
Standby Mode
LED Display
Power On / Off
Mist Adjustment
Humidity Setting
Warm Mist Adjustment
AUTO Mode
Sleep Mode
Timer Setting
Low Water Protection
Memory Function
CONTENTS
01
01
06
08
10
07
06
02/03
04
05
08
08
10
11
11
12
12
11
11
12
09
09
10
10
CLEANING AND MAINTENANCE
Caution
Daily Maintenance
Weekly Maintenance
Scale Removal Instructions
Disinfecting Instructions
Cleaning the Aroma Pad
Cleaning the Dustproof Sponge
End-of-Season Care and Storage
Battery Replacement
TROUBLESHOOTING GUIDE
WARRANTY
PARIS RHÔNE CUSTOMER CARE
15
15
16
13
13
13
13
13/15
16
16
17
19
19

STATEMENT
SAFETY INSTRUCTIONS
The humidifier was made with safe and environmental protection materials, it has been certified
and complied with the requirement of sale regions’ related regulations or laws.
IMPORTANT: Please read and save this SAFETY INSTRUCTIONS before using the device. Basic
precautions should always be followed to reduce the risk of fire, electrical shock, and injury to
persons or damage to the product.
BEFORE USING THE HUMIDIFIER
1. Please extend the cord and check any signs of damage. Do not use the humidifier if the cord
has been damaged.
2. DO NOT place this humidifier in wet environments.
Please always keep the humidifier out of reach of patients & children & pet.
1. Please always place the unit on a smooth, flat, lint-free, non-metallic, waterproof and level
surface and keep it away from direct sunlight.
2. Always place the unit 2 feet (60 cm) above the floor, 12 inches (30 cm) away from the wall,
other appliances or wooden furniture.
02
1
30 CM
60 CM
2
30 CM
12
01
Thanks for choosing Paris Rhône Ultrasonic Cool Mist Humidier.
This product is covered with Paris Rhône product and labor warranty for 12 months from the
date of its original purchase.
The warranty will not apply in cases of:
- Accident, misuse, or repairs performed by unauthorized personnel.
- Any unit that has been tampered with or used for commercial purpose.
- Normal wear and tear of wearable parts.
- Use of force, damage caused by external inuences.
- Damage caused by non-observance of the User Manual, e.g. connection to
an unsuitable mains supply or non-compliance with the instructions.
- Partially or completely dismantled appliances.
- Defects caused by or resulting from damages from shipping or from repairs,
service, or alteration to the product or any of its parts that have been
performed by a repair person not authorized by Paris Rhône.
We can only provide after-sales service for products that are sold by Paris Rhône or Paris
Rhône authorized retailers and distributors. If you have purchased your unit from a different
place, please contact your
seller for return and warranty issues.
※Please have your invoice and order ID ready before contacting
Customer Support.

DO NOT place the humidifier near naked flames
and heat sources, such as stove tops, ovens,
radiators or computers.
WHEN USING THE HUMIDIFIER
1. DO NOT plug the unit with wet hands.
2. DO NOT use your hand or any other object to cover the nozzle while the unit is on to avoid
damaging the product or causing injury.
1. DO NOT clean the unit while it is connected to a power source or while it is on.
2. DO NOT move or tilt the humidifier while it is in operation.
The most comfortable environmental humidity is
between 40%-60%. Please adjust the mist as needed.
1
12
04
03
2
Humidity
40% 60%

AFTER USING THE HUMIDIFIER
1. Always disconnect from a power source by pulling the plug when not in use.
2. Humidifier requires regular cleaning. Please refer to, and follow the Cleaning and
Maintenance instructions.
1. DO NOT clean the humidifier right after turning it off if the humidifier has been diffusing warm
mist. Allow the humidifier to completely cool down before cleaning.
2. DO NOT attempt to repair or adjust any electrical or mechanical functions on this humidifier.
Doing so will void your warranty.
• 1 x Paris Rhône Top-Fill Hybrid Ultrasonic Humidifier
• 1 x Remote Control
• 1 x Cleaning Brush
• 3 x Mineral Absorption Pads (1 pre-installed)
• 3 x Aroma Pads (1 pre-installed)
• 3 x Dustproof Sponge (1 pre-installed)
• 1 x User Guide
PE-AH009
300 ml/h (High)
200 ml/h (Medium)
100 ml/h (Low)
550ml/h (Max)
100-120V~ 50 / 60 Hz
6.0L / 1.59Gal
280W
10-60h
430-753 ft ² /40–70m²
Model
Cold Mist Output
Warm Mist Output
Voltage
Water Tank Volume
Power
Working Time on a Full Tank
Applicable Space
PACKAGE CONTENTS
SPECIFICATIONS
12
12
06
05
2 2

1. Nozzle
2. Tank Cover
3. Water Tank
4. LED Display
5. Control Buttons
6. Base
7. Aroma Box
8. Power Cord
9. Mist Tube
10. Water Floater
11. Heating Element
12. Water Reservoir
13. Atomizer
14. Air Outlet
OPERATIONS AND FUNCTIONS
1 2 3
Add Water
1. Remove the tank cover.
2. Fill the tank with filtered or purified water.
3. Place the tank cover back.
PRODUCT DIAGRAM
08
07
1
2
6
11
3
4
5
7
8
9
10 12
13
14
Add Essential Oil (Optional)
1. Remove the aroma box (at the back of the base) by pulling it out.
2. Add several drops of essential oil to the aroma pad. Insert the aroma box back after adding the
essential oil.
1 2

10
09
1234
1. If tap water is too hard, it is recommended to use filtered or distilled water to avoid white
dust. DO NOT use hot water.
2. DO NOT add any essential oils or medicinal tablets into the water tank.
3. DO NOT add water into the base or through nozzle.
4. DO NOT move the humidifier while the water tank is full of water to avoid leakage or base
overfilling.
5. You can fill the water tank without removing it from the base, pay attention to avoid water
getting into the air outlet.
5
Standby Mode
• Connect the humidifier to a power source, the unit is in Standby mode now with a beep. The LED
display and all control buttons will light up for 2 seconds.
• If no operation is done within 2 seconds under Standby mode, the LED display will turn off
automatically.
LED Display
• Shows the current environmental %humidity level (Relative Humidity).
• Shows the set mist level (2, 3, 1) while setting.
• Shows the set %humidity level (40% ~ 80% RH) while setting.
• Shows the set time (0 ~ 9H) while setting.
Power On / Off
• Tap the Power Button once to turn the humidifier ON with default settings: medium mist (level 2),
warm mist (level 3) & current environmental humidity.
• When there is not enough water inside the water reservoir, the humidifier will stop misting and Low
Water Protection will be activated. The LED display will flash 3 times with 3 beeps.
• Tap it again to turn the humidifier OFF. The fan will continue working for 3 minutes to dry the mist
tube.
Mist Adjustment
• When the unit is on, tap the Mist Button to cycle through Medium (level 2) -> High (level 3) -> Low
(level 1) mist levels. The corresponding mist level will light up on the LED Display.
• The set mist level will flash three times to confirm your setting.
Mist Adjustment Humidity Setting
Sleep Mode
Power ON/OFF
Warm Mist
Adjustment Timer Setting
AUTO Mode
Note: For added convenience, the same control buttons can be found on the remote control.
Control Buttons
Remote Control

Humidity Setting
• Tap the Humidity Button to set the humidity level from 40% to 80% in 5% increments, the set
humidity level will flash three times to confirm your setting.
• When the preset humidity level is reached, the unit will stop misting.
• To cancel Humidity setting, tap and hold the Humidity Button for 2 seconds or repeatedly tap the
Humidity Button until “--” is displayed.
The most comfortable environmental humidity is between 40%-60%. Please adjust the mist as
needed.
Warm Mist Adjustment
• Tap the Warm Mist Button to cycle through High (level 3) -> Medium (level 2) -> Low (level 1) heat
levels -> OFF. The corresponding heat level will light up on the LED Display.
• The set heat level will flash three times to confirm your setting.
AUTO Mode
• Tap the AUTO button to activate the automatic humidifying mode.
• Under AUTO mode, the mist level and heat level are automatically adjusted based on the environ-
mental humidity to the most comfortable level (55%~65%).
• Once 65% humidity is reached, the humidifier will shut off automatically. When the environmental
humidity is below 60%, the unit will restart working again.
• When AUTO mode is activated, changing the mist level or heat level will cancel the AUTO mode.
Sleep Mode
• Tap and hold the AUTO Button on the control panel for 2 seconds or directly press the Sleep Button
on the remote control to turn off the LED display with a beep.
• To turn the display back on, tap any button on the control panel to wake it up. If no operation is
done within 3 seconds, the LED display will turn off automatically.
12
11
• When Low Water Protection is activated under sleep mode, the LED display will flash 3 times
without beeps. Tap and hold the AUTO Button for 2 seconds again to turn off the LED display with a
beep.
Timer Setting
• Tap the Timer Button to set the timer from 1 to 9 hours by 1 hour increments, the timer will flash
three times to confirm your setting. When time is up, the unit will automatically turn off.
• To cancel Timer setting,
1. Keep tapping the Timer button until “0H” displayed or
2. Tap and hold the Timer Button for 2 seconds.
Low Water Protection
• When there is not enough water inside the water reservoir, the humidifier will stop misting and Low
Water Protection will be activated. The LED display will flash 3 times with 3 beeps. It is designed for
safety to prevent the humidifier from possibly overheating and damaging the atomizer.
• The humidifier cannot be started under low water status.
Memory Function
If power is not disconnected, the humidifier will always remember your last settings (except timer
setting) once you turn it on again.

4. Fill the water tank half full. Add in 1 teaspoon of undiluted distilled white vinegar.
5. Place the water tank onto the base. The vinegar solution will enter the water reservoir to loosen
mineral buildup (scale) on the atomizer, water floater and the bottom of the water tank. Set it still
for 15-20 minutes.
6. Clean all parts of the water reservoir with the included cleaning brush to remove any mineral
buildup.
7. Rinse both the water reservoir and water tank until the smell of vinegar (for scale removal) or
bleach solution (for disinfecting, see below) is gone.
CLEANING AND MAINTENANCE
Caution
1. DO NOT submerge the base in water.
2. Make sure water does not enter the base through the air outlet, air inlet,
or the control buttons and LED display.
3. DO NOT wash any part of this humidifier in dish washer which will
damage the humidifier and void the warranty.
Daily Maintenance
Turn off the humidifier, unplug it from the power source. Drain water from the tank, reservoir and
base.
Weekly Maintenance
1. To properly clean your humidifier, we recommend you to remove scale and disinfect the
humidifier separately.
2. DO NOT mix vinegar and bleach solutions together. Do not use more than 1 tsp. of
bleach per gallon of water to avoid damaging your humidifier.
Scale Removal Instructions
14
13
1
4
6
7
5
2
3
Absorption Pad
15-20
minutes
1. Turn off and unplug the humidifier.
2. Remove the water tank from the base and
pour out any remaining water.
3. Remove the absorption pad inside the
heating element and rinse under clean
water. Dry the pad with a clean, dry cloth.

Disinfecting Instructions
Disinfecting the humidifier removes any remaining bacteria or mold after cleaning both the water
tank and water reservoir. It is recommended to disinfect your humidifier at least once a week with
regular use as well as before and after storing for long periods of time.
1. Clean the water tank and water reservoir as instructed in the previous section.
2. Fill the water tank half full. Add in ½ tsp of bleach.
3. Allow the solution to soak for at least 30 minutes, but no longer than 1 hour.
4. Pour out the solution and rinse both water tank and water tank under cold water. Allow all parts to
air dry before reassembling.
End-Of-Season Care and Storage
1. Follow the cleaning instructions when the humidifier will not be used for at least one week,
or at the end of the season. Remove any accessories used with the humidifier and allow the
humidifier and accessories to dry completely before storing.
2. DO NOT store with water inside the base, water reservoir, or tank.
3. Pack the unit safely and store in a cool, dry location.
16
15
Note:
It is recommended to change the absorption pad every 2-4 weeks depending on water hardness.
Cleaning the Aroma Pad
1. To clean the aroma pad, remove it from the aroma box.
2. Rinse the pad under warm water, then dry it with a clean cloth and place it back into the aroma box.
Note: It is recommended to change the aroma pad every 6 months.
12
Aroma Pad
Cleaning the Dustproof Sponge
1. To clean the dustproof sponge, remove it from the aroma box and clean with water or detergent
once a month.
2. Put it back in place after cleaning.
Dustproof
Sponge
Holder
+
-
A
B
Battery Replacement
1. Remove the battery holder by pressing the locking tab A with your thumb and pulling it out as per
arrow B.
2. Properly dispose the old battery.
3. Replace with a new CR2025 Type Lithium Battery, making sure the (+) side facing up.
4. Gently push in the holder until securely locked into place.
CAUTION:
·Danger of explosion if battery is incorrectly
replaced. Replace only with the same or
equivalent type.
·Do not attempt to dismantle or charge the
batteries.
·Do not dispose the batteries in fire, batteries
may explode or leak.

TROUBLESHOOTING GUIDE
1. If the information listed in the troubleshooting guide can’t solve your problem, please
2. Failure to keep this unit clean from mineral deposits may affect operation of this unit.
3. Customer failure to follow these instructions may void the warranty.
18
17
Troubleshooting Guide
Problem Possible Causes Solution
LED display does not
light up
Power cord is not properly
plugged in.
Ensure the unit is properly
plugged in.
No power from power outlet. Try another power outlet.
LED display and
indicators flash with
beeps
Not enough water inside the water
reservoir. Add water into the water tank.
LED display is on, no
mist or little mist is
produced
Not enough water inside the water
reservoir. Add water into the water tank.
Mist level is set too low. Adjust to the maximum mist.
Humidity is set too low.
Check if the current humidity is
higher than the preset humidity,
reset to a higher level.
Mineral buildup on the atomizer. Clean the atomizer as instructed.
Problem Possible Causes Solution
Mist height is low,
damping surrounding
desk or floor.
Condensation forms
around humidifier or
on windows and walls
Mist level is set too high for the
room size.
1.Check if the room is too humid
and adjust to lower mist. 40%-
60% works best.
2.Open door and windows, or
change to a larger room.
Air inlet is blocked.
Humidifier should be placed on
a hard flat surface, 2 feet above
the floor and 12 inches away
from the wall. Point nozzle away
from wall or window.
Low indoor temperature leads to
liquefaction.
Raise the room temperature to
25°C/77°F.
Bad / Strange odor Unit needs to be cleaned.
1.Clean the humidifier as
instructed.
2.Leave the empty and opened
water tank in a cool place for
12 hours without the tank cap
attached.
Strange water noise Water is going down to the water
reservoir. This is normal while it is working.
Humidifier is getting
too hot Unit works for long period of time. Power off and place in a well-
ventilated place for 10 minutes.

Thanks for choosing Paris Rhône Hybrid Ultrasonic Humidifier.
The warranty will not apply in cases of:
- Misuse, dismantling, or repairs performed by unauthorized personnel.
- Any appliance that has been tampered with or used for commercial purpose.
- Use of force, natural hazards, damage caused by external influences.
- Damage caused by non-observance of the User Manual, e.g. connection to an unsuitable mains
supply or non-compliance with the instructions.
- Partially or completely dismantled appliances.
- Defects caused by or resulting from damages from shipping or alteration to the product or any of
its parts that have been performed by unauthorized personnel.
We can only provide after-sales service for products that are sold by Paris Rhône or Paris Rhône
authorized retailers and distributors. If you have purchased your appliance from a different place,
please contact your seller for return and warranty issues.
※Please have your invoice and order ID ready before contacting Customer Support.
PLEASE CONTACT US BEFORE RETURNING THIS PRODUCT TO THE STORE.
EMAIL PARIS RHÔNE CUSTOMER CARE FOR PROBLEMS AND QUESTIONS.
WE WILL RESPOND WITHIN 1 BUSINESS DAY.
WARRANTY
CONTACT / PARIS RHÔNE CUSTOMER CARE
E-mail: [email protected]
Website: www.parisrhone.co
19
FCC Compliance
This device complies with Part 18 of the FCC Rules. Operation is subject to the following two conditions:
(1) This device may not cause harmful interference, and
(2) This device must accept any interference received, including interference that may cause
undesired operation.


Rev_1.1_EN
Manufacturer: Shenzhen NearbyExpress Technology Development Co.,Ltd.
Address: Floor 7, Building E, Galaxy World Phase II, Shenzhen, China
www.parisrhone.co
Made In China

尺寸:150*200mm
装订成册
材质:封面128克铜版纸 内页80克书纸
Table of contents
Other Paris Rhone Humidifier manuals