pathway 4802 Assembly instructions

The two PWR LEDs on the Installation
Repeater will illuminate when AC power is
connected to the unit. There is no on/off
switch.
The two DATA LEDs will illuminate and
flicker rapidly to indicate that DMX data is
being received.
Two TEST indicators are associated with
the DMX input and each of the six outputs.
Refer to the Cable Test Feature instruc-
tions.
Indicators
Power
Supply: Universal input (90-250V,
50/60Hz), 0.2A
Isolation: 2500V Opto-isolation on DMX lines
4000V Mains isolation
Protection: Up to 250VAC/DC on all
port pins
Protocols: DMX512, DMX512-A, or any EIA422
or 485 based simplex protocol
Size: 19 x 10 x 3in. (483 x 254 x 76 mm)
Specifications
DMX512-A Compliance
The Pathway Installation repeater is com-
pliant with DMX512-A under the non-
compatible connector (NCC) provision.
All ports are DMX512-A protected to
250V with self-healing circuitry.
Subject to change without notice 103 Inglewood Plaza 1439 17Avenue SE Calgary AB, Canada T2G 1J9 • +1 403 243-8110 Fax +1 403 287-1281
Printed in Canada R8
D - ON Data present on
D + ON incoming DMX line
D - OFF D- signal missing
D + ON or shorted to common
D - ON D+ signal missing
D + OFF or shorted to common
D - OFF No data present on incoming
D + OFF DMX line
via the input connection, as per the previ-
ous instructions. Once that is verified, dis-
connect the cable to the suspect output
channel and depress the corresponding
ISO OUT TEST button. If both the corre-
sponding D- and D+ LEDs illuminate, this
shows that the isolated output circuitry
inside the repeater is working properly and
is transmitting both DMX512 signals. If
not, there is likely a problem with the out-
put circuitry for that channel. Try using the
spare transceiver chip to remedy the prob-
lem. Now reconnect the cable to the sus-
pect output and perform the same test. If
both of the D- and D+ LEDs illuminate, this
shows that there are no shorts in the out-
put cabling or connected receiving de-
vices. If one or both of the LEDs is off or
dim, a cable or device problem is indi-
cated. NOTE: if an output TEST button is
pushed when a proper input signal is not
being received by the Installation Re-
peater, the outputs will be in their normal
“idle” state (i.e. D- low level, D+ high
level), therefore the D+ LED will illuminate
and the D- LED will not.
INPUT TEST
INDICATIONS
Cable Test Feature cont.
4802 Installation Repeater
6-way opto-isolated DMX splitter
To ensure trouble free operation, DMX512
standards require that DMX devices be
installed in a daisy chain, with no tees,
wyes or stars in the DMX wiring. However,
site conditions may make star wiring
desirable or even mandatory. A Pathway
DMX Repeater permits star wiring by
making each branch of the star function
electrically as its own entity, unaffected by
the other branches of the star.
Additionally, opto-isolation circuitry
isolates each branch to prevent ground
loops or accidental damage from fault
voltages on DMX lines.
Operational Philosophy
• All cabling must be in a continuous run,
daisy-chained, no “Tees” allowed
• “Stars” are permitted only in conjunction
with a repeater
• Cable shield may be earth-grounded at
one end only, preferably at the control
console
• Maximum length of one cable segment
is 1,800 ft. (550m)
• Receiving devices have male
connectors, transmitters have female
• The last DMX device on the line must be
terminated with a termination switch or
resistor with a value of 100 to 120 ohms
between pins 2 and 3.
• 5 pin XLR type DMX connectors are
standard:
Pin 1: Common
Pin 2: Data (-)
Pin 3: Data (+)
Pin 4: Optional Data (-)
Pin 5: Optional Data (+)
• Cable must be Belden 9842 (120Ω),
9829, 9729 (100Ω), ISO/IEC 11801
(Cat5) or equivalent
• A maximum of 32 DMX receiving
devices can be present on a single DMX
line
DMX Wiring
INSTALLER’S
GUIDE
4802 Installation Repeater
6-way opto-isolated DMX splitter
Mounting
Installation Repeaters are designed for
indoor use, in a dry location. Mount the
Installation Repeater with appropriate fas-
teners to the wall. Run conduit into the
box through the knockouts provided, en-
suring that line voltage wiring is kept inside
the barriered power supply section.
An essential component of any
DMX512 distribution system, the
Installation Repeater permits star
wiring installations while isolating
and protecting connected
equipment from harmful electrical
faults. Pathway Installation
Repeaters feature self-healing
protection devices on all ports to
prevent internal damage when
severe faults of up to 250V are
accidentally applied to the
connected DMX cabling. To help
you resolve any cable, signal or
component issues fast, there are
useful test functions built right into
the product.

Connections
Typically, Pathway Installation Repeaters
are wired in the following configuration:
• DMX Input is connected to the control
console DMX output
• DMX Outputs (ISO Out A,B,C,D,E, &
F) are connected to the remote DMX
devices or receptacles for the
equipment receiving the console
signal. These may be dimmers,
scrollers or moving lights, for example.
• DMX Thru passes the console signal
to additional DMX Repeaters or other
similar devices,and would in turn be
connected to DMX Input on the next
unit in line.
• Power. With the power off, make the
appropriate connections to Line, Neu-
tral and Ground.
2-piece screw terminal connectors are
provided. The pin arrangement of these
connectors is the same as that of 5 pin
XLR connectors.
Screw Terminal
Connections
Always disconnect power before re-
moving the cover. Installation
Repeaters are designed to work on
voltages from 90-250 volts AC. They
will automatically sense the incoming
voltage and adjust accordingly.
CAUTION!
WARNING!
All DMX input/output ports must only
be connected to low-voltage data lines.
Do not connect high voltage sources to
these connectors.
Recommended Wiring
Practice
Keep all DMX cabling away from high
voltage/power cables to maintain data
integrity. Cable must be Belden 9842 (120
Ω), 9829, 9729 (100Ω), ISO/IEC 11801
(Cat5) or equivalent
4802 Installation Repeater
6-way opto-isolated DMX splitter
Line voltage
input DMX
Input DMX
Thru DMX
Output (6)
Test
LEDs
Output Test
Buttons (6)
DMX Terminate
Button
Input Test
Button
Data
LED
Power
LED
DMX Termination
Cable Test Feature
Pathway 4802 Installation Repeaters
provide installers with the unique ability to
test the integrity of the incoming and out-
going DMX signal and cabling. This fea-
ture makes troubleshooting most DMX
communication problems easy and can be
accomplished right at the repeater, without
any additional test gear. “TEST” pushbut-
tons are provided for the DMX input and
each of the six outputs.
The DMX signal runs on two separate
data lines: D- (XLR pin 2) and D+ (XLR pin
3). Both are referenced to signal common
(XLR pin 1). For DMX512 to work reliably,
the D- and D+ signals and common must
be present and properly connected at both
ends of the cable. Often, a system will
seem to work fine most of the time with
one of the three connections missing or
with two wires shorted – this simply shows
how fault tolerant DMX can be! But inter-
mittent problems will usually appear at
random, often at the worst possible time.
INPUT TROUBLESHOOTING
Normally when troubleshooting a com-
If only one Installation Repeater is used,
and nothing is connected to the DMX
THRU terminal block, the red termination
switch must be set to the ‘in’ position (ON)
to terminate the incoming DMX signal from
the console. If several Installation
Repeaters are connected together using
the DMX THRU connector on each unit,
only the last Installation Repeater in the
chain is terminated, all the others are not
terminated (switch in the ‘out’ position).
Cable Test Feature cont.
munications problem it is common practice
to start with the DMX512 source (console
signal). The amber DATA indicators may
or may not be illuminated at this point. If
they are not, first make sure that the con-
sole is on and sending a DMX signal.
Then, depress the DMX INPUT test button
on the repeater; this will disconnect the
incoming signal from the receiver circuitry
and apply it to the red D- and green D+
LEDs. Both of them should illuminate (the
DATA indicators will go out). This shows
that the console’s DMX transmitter is ca-
pable of sending a strong enough signal to
drive the two test LEDs, and that all three
pins are connected. If the DATA indicators
are always off and both of the D- and D+
LEDs work with the TEST button de-
pressed, the Installation Repeater’s re-
ceiver may be defective (a spare trans-
ceiver chip is located on the main circuit
board, inside the unit). If either or both of
the D- and D+ LEDs stay off when the
TEST button is pushed, there is a problem
with the console’s output or the DMX ca-
ble.
NOTE: the TEST LEDs can also detect
whether the D-/D+ wires are swapped.
With a DMX signal present, set all console
channel levels to zero and depress the
Input TEST button. The D- LED should be
brighter than D+. When all channels are
set to full, D+ should be the brightest.
OUTPUT TROUBLESHOOTING
Installation Repeater outputs should be
tested in stages to determine if a problem
exists in the repeater output circuitry or in
a cable or device connected to that re-
peater channel. First, ensure that the re-
peater is correctly receiving DMX512 data
Typical Application
HOUSE
DIMMERS
STAGE
DIMMERS
CONTROL CONSOLE
DMX
Repeater DMX
Repeater
RELAY
CABINET
COLOR
SCROLLERS MOVING
LIGHTS MOVING
LIGHTS
THRU ININ
Table of contents
Other pathway Repeater manuals