manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. pathway
  6. •
  7. Repeater
  8. •
  9. pathway PWREP RM P8 User manual

pathway PWREP RM P8 User manual

Other pathway Repeater manuals

pathway DMX repeater pro User manual

pathway

pathway DMX repeater pro User manual

pathway 901 Series User manual

pathway

pathway 901 Series User manual

pathway 4802 Assembly instructions

pathway

pathway 4802 Assembly instructions

Popular Repeater manuals by other brands

Kenwood TKR-750-850 Function reference

Kenwood

Kenwood TKR-750-850 Function reference

Asus RP-AC51 quick start guide

Asus

Asus RP-AC51 quick start guide

Exibel HRP0101 instruction manual

Exibel

Exibel HRP0101 instruction manual

Kenwood TKR-750 Service manual

Kenwood

Kenwood TKR-750 Service manual

York Universal LINC485 installation manual

York

York Universal LINC485 installation manual

MIKOM MRx01B Power Series user manual

MIKOM

MIKOM MRx01B Power Series user manual

Simrad RD 301 instruction manual

Simrad

Simrad RD 301 instruction manual

Inventronics DALI REPEATER SO operating instructions

Inventronics

Inventronics DALI REPEATER SO operating instructions

XFP 16 installation manual

XFP

XFP 16 installation manual

Andrew MRx18 user manual

Andrew

Andrew MRx18 user manual

COMBA RXA3748 user manual

COMBA

COMBA RXA3748 user manual

ADRF SDR-ICS-43 user manual

ADRF

ADRF SDR-ICS-43 user manual

Teltonika WRP100 user manual

Teltonika

Teltonika WRP100 user manual

U-Prox HW installation manual

U-Prox

U-Prox HW installation manual

Motorola VRS750 Service manual

Motorola

Motorola VRS750 Service manual

KanexPro SDI-HDRPTPRO user manual

KanexPro

KanexPro SDI-HDRPTPRO user manual

Ltech LT-3030-CС quick start guide

Ltech

Ltech LT-3030-CС quick start guide

Gigaset 108 owner's manual

Gigaset

Gigaset 108 owner's manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

Model PWREP RM P8
DMX Repeater Manual
08/27/21
5-PIN XLR (STANDARD)
3-PIN XLR (NON-STANDARD)
SCREW TERMINAL CONNECTIONS
Model PWREP RM P8 TERM REAR NONRDM uses pluggable
screw terminal connectors on the rear panel. The pinout arrangement
is the same as 5-pin XLR connectors above.
The DMX512-A standard requires that DMX devices be
installed in a daisy chain, with no tees, wyes or stars in the
data wiring. However, site conditions may make star wiring
desirable or even mandatory.
The Pathway PWREP RM P8 NONRDM permits star-wiring
layouts by making each output a separate electrical entity,
thereby protecting connected equipment from harmful
electrical faults and ground loops.
DMX INPUT
Connect to the DMX output of the controller or console using an
appropriate cable for the connector type on your model. (See below
for pinout information).
DMX OUTPUTS
Connect to the remote output receptacles and/or DMX-controlled
devices receiving the console signal.
DMX THRU
Passes the console signal to additional PWREP RM P8 NONRDM
units or similar devices when connected to the DMX input on the
next unit in line. This connection is passive and unisolated and will
work if the power to the PWREP RM P8 NONRDM is lost.
OVERVIEW
CONNECTIONS
CONNECTOR PIN OUT STATUS INDICATORS
DMX TERMINATION
CONNECTOR PIN OUT (CONT’D)
RJ45 etherCON CONNECTORS
Model PWREP RM P8 RJ45EC REAR NONRDM and PWREP RM
P8 RJ45EC FRONT NONRDM use RJ45 etherCON connectors.
The following is the ANSI standard wiring pin out for DMX-over-
Category wire.
DMX rules require the last device on a DMX line to be terminated with
a 120Ω resistor between pins 2 and 3 to prevent signal reection.
The Repeater has a termination switch to accomplish this.
If there is no connection to the DMX THRU terminals,
the DMX Terminate switch should be ON (pressed in
and latched).
If there are other devices connected to the DMX THRU
terminal, the DMX Terminate switch should be OFF (in
the out position). Ensure termination is applied to the
nal device in the daisy-chain.
POWER
(MAIN)
Blue. Located next to the DMX INPUT port.
Steady glow indicates main power input is OK. O󰀨
indicates no power.
POWER
(PORT)
Blue. Located next to each port. Steady glow
indicates port power is OK. O󰀨 indicates a problem
with internal port power supply.
DMX IN Amber. Located above Main Power LED. Steady
glow or glow with icker indicates valid DMX input.
O󰀨 indicates no DMX input.
DMX
OUTPUT
Green. Located next to each port. Steady glow or
glow with icker indicates DMX output by that port.
O󰀨 indicates no DMX output at that port.
XLR PIN # PURPOSE
1Shield
2Data - (complement)
3Data + (true)
4Not Used
5Not Used
XLR PIN # PURPOSE
1Shield
2Data - (complement)
3Data + (true)
XLR PIN # CAT5/6 Pin # and Color PURPOSE
31 - White/Orange Data 1 + (true)
22 - Orange Data 1 - (complement)
53 - White/Green Not Used
46 - Green Not Used
-4 - Blue Not Used - do not connect
-5 - White/Blue Not Used - do not connect
17 - White/Brown Shield/COM
18 - Brown Shield/COM
Model PWREP RM P8
DMX Repeater Manual
08/27/21
© 2021 Acuity Brands, Inc. • One Lithonia Way, Conyers GA 30012
Pathway Connectivity | #103 - 1439 17th Ave SE Calgary, AB Canada T2G 1J9
Phone: + 1 866 617 3074 www.pathwayconnect.com
• 100-240VAC 50/60Hz wide-range power input
• 0.08A maximum power consumption
• 3000V opto-isolation between DMX data links
• 250V fault protection on DMX ports
• Star wiring is permitted only in conjunction with a repeater
• All cabling must be a continuous daisy-chain. No “tees” are
permitted
• Cable shield is earth-grounded at one end only, preferably at the
control console
• Maximum length of one cable segment is 1,800 ft. (550m)
• The last DMX device on the line must be terminated with a 100
or 120Ω resistor between pins 2 and 3
• Cable must be Belden 9842 (120Ω), 9829, 9729 (100Ω), ISO/
IEC 11801 (Cat5) or equivalent
• Keep all DMX cabling away from high voltage or power cables
to maintain data integrity
When equipped with 5-pin XLR connectors, this product complies
with the current ANSI E1.11 DMX512-A standard and all previous
standards to DMX512 (1990).
Screw terminal connector and RJ45-equipped models are compliant
with E1.11 DMX512-A under the non-compatible connector (NCC)
provision. RJ45-equipped models are intended for installation in
restricted-access equipment rooms and should not be used as
portable gear. Accidental connection to data switching or other
equipment may cause damage to equipment and/or personal injury.
All DMX ports are protected to 250V with self-healing circuitry.
PWREP RM P8 NONRDMs are intended for desktop use, or may
be mounted in a standard 19” equipment rack, using the rack ear
kit included.
Truss-mount adaptors (PWACC TMLG) and wall-mount adaptors
(PWACC WMLG) are also available.
The PWREP RM P8 NONRDM is intended for installation in a dry,
indoor location. Operating conditions: 14°F-122°F (-10°C to 50°C);
5-95% relative humidity, non-condensing.
Warning: The AC socket outlet shall be installed near the
equipment and shall be easily accessible.
Warning: This equipment relies upon building installation primary
overcurrent protection.
Warning: Except for the IEC chassis plug marked for AC input,
all ports on the PWREP RM P8 NONRDM are intended for
low voltage data lines only. Attaching anything other than low
voltage sources to the data ports may result in severe equipment
damage, personal injury or death.
DMX BASICS
DMX512-A COMPLIANCE
INSTALLATION
• ANSI E1.11 DMX512-A R2013
• UL
• RoHS 2011/65/EU + A1 2015/863
• CE
COMPLIANCE
• 5.2 lbs (2.4 kg)
• 17”W x 1.7”H x 7”D (432mm x 43mm x 178mm)
• Operating Conditions: 14°F-122°F (-10°C to 50°C); 5-95%
relative humidity, non-condensing
PHYISCAL
ELECTRICAL INFORMATION