Contents
1Safety notes........................................................................................... 1
2Features ................................................................................................. 2
3Detectable gases...................................................................................2
4Technical specifications ...................................................................... 3
5Delivery contents .................................................................................. 3
6Device description ................................................................................ 4
7Operation ............................................................................................... 1
7.1 Before first use................................................................................................................. 1
7.2 Before use........................................................................................................................ 1
7.3 Use.................................................................................................................................. 2
8Further functions .................................................................................. 3
8.1 Auto zero.......................................................................................................................... 3
8.2 Auto Power Off................................................................................................................. 3
8.3 Sensitivity......................................................................................................................... 3
8.4 Alarms.............................................................................................................................. 3
9Troubleshooting....................................................................................3
10 Warranty.................................................................................................4
11 Disposal ................................................................................................. 4

© PCE Instruments
1
1 Safety notes
Please read this manual carefully and completely before you usethedevice for the first time. The
device may only be used by qualified personnel and repaired by PCE Instruments personnel.
Damage or injuries caused by non-observance of the manual are excluded from our liability and
not covered by our warranty.
•The device must only be used as described inthis instruction manual.If used otherwise,
this can cause dangerous situations for the user and damage to the meter.
•The instrument may only be used if the environmental conditions (temperature, relative
humidity, …) are within the ranges stated in the technical specifications. Do not expose
the device to extreme temperatures, direct sunlight, extreme humidity or moisture.
•Do not expose the device to shocks or strong vibrations.
•The case should only be opened by qualified PCE Instruments personnel.
•Never use the instrument when your hands are wet.
•You must not make any technical changes to the device.
•The appliance should only be cleaned with a damp cloth. Use only pH-neutral cleaner,
no abrasives or solvents.
•The device must only be used with accessories from PCE Instruments or equivalent.
•Before each use, inspect the case for visible damage. If any damage is visible, do not
use the device.
•Do not use the instrument in explosive atmospheres.
•The measurement range as stated in the specifications must not be exceeded under
any circumstances.
•Non-observance of the safety notes can cause damage to the device and injuries to
the user.
•The meter must not be used as a gas detector.
We do not assume liability for printing errors or any other mistakes in this manual.
We expressly point to our general guarantee terms which can be found in our general terms of
business.
If you have any questions please contact PCE Instruments. The contact details can be found at
the end of this manual.

© PCE Instruments
2
2 Features
−Detection of flammable gases
−Vibration alarm when gases are detected
−Automatic calibration
−Measurement range up to 10000 ppm
−Audible alarm, 85 dB
−Sensor exchangeable
−Shelf life of the sensor approx. 5 years
−Rechargeable battery for mobile use
3 Detectable gases
−Ammonia
−Benzene
−Ethane
−Ethanol
−Ethylene
−Formaldehyde
−Hexane
−ISO-Butane
−Methane
−Propane
−P-Xylene
−Hydrogen sulfide
−Toluene
−Hydrogen
−and compounds in which these gases occur

© PCE Instruments
3
4 Technical specifications
Measurement range
Low concentration: 0 ... 1000 ppm,
High concentration: 0 ... 10000 ppm
(methane only)
Audible alarm
Volume: 85 dB
Sensitivity
<50 ppm (methane)
Measuring interval
<2 seconds
Display
5 red LEDs
Calibration
Automatic
Warm-up time
50 seconds
Battery
Polymer Li-Ion battery 18500 3.7 V 1400 mAh
Mains adaptor
Primary side: 100 ... 240 V, 50/60 Hz, 0.2 A
Secondary side: 5 V, 1 A
Auto Power Off
Turns off automatically when battery is low or after 10 minutes
of inactivity
Sensor shelf life
approx. 5 years (sensor is exchangeable)
Probe
Semi-rigid, approx. 500 mm
Weight
Approx. 430 g
5 Delivery contents
−1 x gas leak detector PCE-GA 10
−1 x charger
−1 x user manual

© PCE Instruments
4
6 Device description
1 –LED warm-up
2 –LED low sensitivity
3 –Automatic zero calibration on/off
4–Vibration alarm on / off
5 –Meter on / off
6 –LED display
7 –LED high sensitivity
8 –Sensitivity high / low
9 –Auto Power Off
10 –Hold on / off
11 –Audible alarm on / off

© PCE Instruments
1
7 Operation
7.1 Before first use
−Fully charge the battery before the first use. The charging socket is located on the right
side above the sensor arm bracket.
−Switch on the meter using the "On / Off"key and leave the device switched on for about
one hour for the sensor to acclimatise. Deactivate the automatic power-off function with
the APO key and set the sensitivity to low. The alarm LEDs will gradually go off. As
soon as only LED 1 flashes, the acclimatization is complete.
−If you do not use the device for more than two months, repeat this procedure.
7.2 Before use
−Check the meter for mechanical damage.
−Only switch on the unit in an environment unpolluted by gas.
−Carry out a gas test with the appropriate test gas.
−Attention! When using a lighter, only move the sensor head very slowly towards
the gas source. A 100 % concentration exposure can destroy the sensor.
−If the gas is not detected, the device is not ready for use.
−After the gas test, wait until all alarm LEDs have gone off when low sensitivity is set.

© PCE Instruments
2
7.3 Use
−Make sure the gas to be detected is listed above.
−Only turn on the meter in an environment unpolluted by gas.
Press and hold the "On / Off" key for about 1 second. The meter will vibrate and a signal
tone will sound.
−Let the meter warm up for 50 seconds. The lower LED will flash.
−The end of the warm-up time is confirmed by the unit by all alarm LEDs flashing 4 times
and the signal tone sounding 4 times.
−When the L and H LEDs are lit simultaneously, charge the device.
−Select the desired sensitivity with the "H/L" key (8).
−Clean the areas to be examined from oil and dust. Oil and dust can impair the detection.
−Slowly move the sensor head to the area to be examined.
−If there is a gas leak, the instrument will signal that gas escapes (see chart below),
depending on the sensitivity setting. Keep in mind the reaction time of at least 2
seconds. Move the sensor head back a little to exactly locate the leak.
−Switch off the meter after the leak detection. To do this, press and hold the "On / Off"
key for about 1 second.
Alarm chart related to methane CH4
Approx. reading in ppm
Frequency
Sensitivity
Alarm LEDs
audible
alarm x/s
high
low
1
2
3
4
5
0
0
Off
Off
Off
Off
Off
no alarm
0 … 100
0 … 1000
On
Off
Off
Off
Off
1
100 … 400
1000 … 4000
On
On
Off
Off
Off
1.2
400 … 700
4000 … 7000
On
On
On
Off
Off
1.65
700 … 1000
7000 … 10000
On
On
On
On
Off
3.25
>1000
>10000
On
On
On
On
On
6.25

© PCE Instruments
3
8 Further functions
8.1 Auto zero
The "Auto Zero" key is used to activate or deactivate automatic zeroing.
Activating it improves sensitivity to the target gas and reduces the sensitivity to other existing
gases.
8.2 Auto Power Off
The automatic power-off function switches off the unit after approx. 10 minutes of non-use to
conserve the battery. With the "APO" key, this function can be deactivated.
8.3 Sensitivity
With the "H/L" key you can adjust the sensitivity according to your needs.
8.4 Alarms
Use the key with the vibration icon or with the speaker icon to switch the corresponding alarm on
or off.
9 Troubleshooting
Error
Possible cause
Solution
Meter cannot be turned on
Battery flat
Charge battery
L and H LEDs are flashing simultaneously
Battery very low
Charge battery
All alarm LEDs and the L and H LEDs are flashing
simultaneously
Sensor defective
Replace sensor
ESS-PCE-GA 10

© PCE Instruments
4
10 Warranty
You can read our warranty terms in our General Business Terms which you can find here:
https://www.pce-instruments.com/english/terms.
11 Disposal
For the disposal of batteries in the EU, the 2006/66/EC directive of the European Parliament
applies. Due to the contained pollutants, batteries must not be disposed of as household waste.
They must be given to collection points designed for that purpose.
In order to comply with the EU directive 2012/19/EU we take our devices back. We either re-use
them or give them to a recycling company which disposes of the devices in line with law.
For countries outside the EU, batteries and devices should be disposed of in accordance with
your local waste regulations.
If you have any questions, please contact PCE Instruments.

© PCE Instruments
5
PCE Instruments contact information
Germany France Spain
PCE Deutschland GmbH PCE Instruments France EURL PCE Ibérica S.L.
Im Langel 4 23, rue de Strasbourg Calle Mayor, 53
D-59872 Meschede 67250 Soultz-Sous-Forets 02500 Tobarra (Albacete)
Deutschland France España
Tel.: +49 (0) 2903 976 99 0 Téléphone: +33 (0) 972 3537 17 Tel. : +34 967 543 548
Fax: +49 (0) 2903 976 99 29 Numéro de fax: +33 (0) 972 3537 18 Fax: +34 967 543 542
www.pce-instruments.com/deutsch www.pce-instruments.com/french www.pce-instruments.com/espanol
Germany United Kingdom Italy
PCE Produktions- und PCE Instruments UK Ltd PCE Italia s.r.l.
Entwicklungsgesellschaft mbH Unit 11 Southpoint Business Park Via Pesciatina 878 / B-Interno 6
Im Langel 26 Ensign Way, Southampton 55010 Loc. Gragnano
D-59872 Meschede Hampshire Capannori (Lucca)
Deutschland United Kingdom, SO31 4RF Italia
Tel.: +49 (0) 2903 976 99 471 Tel: +44 (0) 2380 98703 0 Telefono: +39 0583 975 114
Fax: +49 (0) 2903 976 99 9971 Fax: +44 (0) 2380 98703 9 Fax: +39 0583 974 824
www.pce-instruments.com/deutsch www.pce-instruments.com/english www.pce-instruments.com/italiano
The Netherlands China Hong Kong
PCE Brookhuis B.V. PCE (Beijing) Technology Co., Limited PCE Instruments HK Ltd.
Institutenweg 15 1519 Room, 6 Building Unit J, 21/F., COS Centre
7521 PH Enschede Zhong Ang Times Plaza 56 Tsun Yip Street
Nederland No. 9 Mentougou Road, Tou Gou District Kwun Tong
Telefoon: +31 (0)53 737 01 92 102300 Beijing, China Kowloon, Hong Kong
www.pce-instruments.cn www.pce-instruments.cn
United States of America Turkey
PCE Americas Inc. PCE Teknik Cihazları Ltd.Şti.
711 Commerce Way suite 8 Halkalı Merkez Mah.
Jupiter / Palm Beach Pehlivan Sok. No.6/C
33458 FL 34303 Küçükçekmece - İstanbul
USA Türkiye
Tel: +1 (561) 320-9162 Tel: 0212 471 11 47
Fax: +1 (561) 320-9176 Faks: 0212 705 53 93
www.pce-instruments.com/us www.pce-instruments.com/turkish
Table of contents
Other PCE Instruments Security Sensor manuals
Popular Security Sensor manuals by other brands

Grizzly
Grizzly H7786 Parts Breakdown

Samsung
Samsung SIA-0120D user manual

Tecnar
Tecnar accuraspray CS Quick setup guide

Inficon
Inficon HLD6000 installation manual

Argus Security
Argus Security L-OP-SG Installation guides

Bircher Reglomat
Bircher Reglomat RBM 2 Translation of the original operation instruction

BBC Bircher
BBC Bircher CareMat Translation of the original instructions